Development of Time-Weighted Average Sampling of Odorous Volatile Organic Compounds in Air with Solid-Phase Microextraction Fiber Housed inside a GC Glass Liner: Proof of Concept

被引:8
|
作者
Tursumbayeva, Madina [1 ,2 ]
Koziel, Jacek A. [1 ]
Maurer, Devin L. [1 ]
Kenessov, Bulat [3 ]
Rice, Somchai [1 ]
机构
[1] Iowa State Univ, Dept Agr & Biosyst Engn, Ames, IA 50011 USA
[2] Al Farabi Kazakh Natl Univ, Dept Meteorol & Hydrol, Alma Ata 050040, Kazakhstan
[3] Al Farabi Kazakh Natl Univ, Ctr Phys Chem Methods Res & Anal, Alma Ata 050012, Kazakhstan
关键词
SPME; retracted SPME; TWA SPME; GC-MS; on-site sampling; air quality; air monitoring; VOCs; odor; environmental analysis; TRACE CONTAMINANTS; MONITORING VOCS; SORBENT TUBES; GAS; RECOVERY; SPME;
D O I
10.3390/molecules24030406
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Finding farm-proven, robust sampling technologies for measurement of odorous volatile organic compounds (VOCs) and evaluating the mitigation of nuisance emissions continues to be a challenge. The objective of this research was to develop a new method for quantification of odorous VOCs in air using time-weighted average (TWA) sampling. The main goal was to transform a fragile lab-based technology (i.e., solid-phase microextraction, SPME) into a rugged sampler that can be deployed for longer periods in remote locations. The developed method addresses the need to improve conventional TWA SPME that suffers from the influence of the metallic SPME needle on the sampling process. We eliminated exposure to metallic parts and replaced them with a glass tube to facilitate diffusion from odorous air onto an exposed SPME fiber. A standard gas chromatography (GC) liner recommended for SPME injections was adopted for this purpose. Acetic acid, a common odorous VOC, was selected as a model compound to prove the concept. GC with mass spectrometry (GC-MS) was used for air analysis. An SPME fiber exposed inside a glass liner followed the Fick's law of diffusion model. There was a linear relationship between extraction time and mass extracted up to 12 h (R-2 > 0.99) and the inverse of retraction depth (1/Z) (R-2 > 0.99). The amount of VOC adsorbed via the TWA SPME using a GC glass liner to protect the SPME was reproducible. The limit of detection (LOD, signal-to-noise ratio (S/N) = 3) and limit of quantification (LOQ, S/N = 5) were 10 and 18 mu gm(-3) (4.3 and 7.2 ppbV), respectively. There was no apparent difference relative to glass liner conditioning, offering a practical simplification for use in the field. The new method related well to field conditions when comparing it to the conventional method based on sorbent tubes. This research shows that an SPME fiber exposed inside a glass liner can be a promising, practical, simple approach for field applications to quantify odorous VOCs.
引用
收藏
页数:18
相关论文
共 25 条
  • [1] Time-weighted average sampling of volatile and semi-volatile airborne organic compounds by the solid-phase microextraction device
    Khaled, A
    Pawliszyn, J
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2000, 892 (1-2) : 455 - 467
  • [2] Evaluation of solid-phase microextraction for time-weighted average sampling of volatile sulfur compounds at ppb concentrations
    Lestremau, F
    Andersson, FAT
    Desauziers, V
    Fanlo, JL
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (11) : 2626 - 2632
  • [3] Time-weighted average passive sampling with a solid-phase microextraction device
    Chen, Y
    Pawliszyn, J
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (09) : 2004 - 2010
  • [4] Time-weighted average water sampling with a solid-phase microextraction device
    Ouyang, GF
    Chen, Y
    Pawliszyn, J
    [J]. ANALYTICAL CHEMISTRY, 2005, 77 (22) : 7319 - 7325
  • [5] Solid-phase microextraction fiber development for sampling and analysis of volatile organohalogen compounds in air
    Attari, Seyed Ghavameddin
    Bahrami, Abdolrahman
    Shahna, Farshid Ghorbani
    Heidari, Mahmoud
    [J]. JOURNAL OF ENVIRONMENTAL HEALTH SCIENCE AND ENGINEERING, 2014, 12
  • [6] Solid-phase microextraction fiber development for sampling and analysis of volatile organohalogen compounds in air
    Seyed Ghavameddin Attari
    Abdolrahman Bahrami
    Farshid Ghorbani Shahna
    Mahmoud Heidari
    [J]. Journal of Environmental Health Science and Engineering, 12
  • [7] Analysis of trace contaminants in hot gas streams using time-weighted average solid-phase microextraction: Proof of concept
    Woolcock, Patrick J.
    Koziel, Jacek A.
    Cai, Lingshuang
    Johnston, Patrick A.
    Brown, Robert C.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2013, 1281 : 1 - 8
  • [8] Time-weighted average water sampling in Lake Ontario with solid-phase microextraction passive samplers
    Ouyang, Gangfeng
    Zhao, Wennan
    Bragg, Leslie
    Qin, Zhipei
    Alaee, Mehran
    Pawliszyn, Janusz
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2007, 41 (11) : 4026 - 4031
  • [9] Time-Weighted Average Sampling of Airborne Propylene Glycol Ethers by a Solid-Phase Microextraction Device
    Shih, H. C.
    Tsai, S. W.
    Kuo, C. H.
    [J]. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2012, 9 (07) : 427 - 436
  • [10] Time-weighted average water sampling with a diffusion-based solid-phase microextraction device
    Ouyang, Gangfeng
    Zhao, Wennan
    Alaee, Mehran
    Pawliszyn, Janusz
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2007, 1138 (1-2) : 42 - 46