Solid-phase microextraction fiber development for sampling and analysis of volatile organohalogen compounds in air

被引:15
|
作者
Attari, Seyed Ghavameddin [1 ]
Bahrami, Abdolrahman [1 ]
Shahna, Farshid Ghorbani [1 ]
Heidari, Mahmoud [2 ]
机构
[1] Hamadan Univ Med Sci, Sch Publ Hlth, Dept Occupat Hlth, Hamadan, Iran
[2] Guilan Univ Med Sci, Sch Hlth, Dept Occupat Hlth, Rasht, Iran
关键词
Solid phase microextraction; Single walled carbon nanotubes; Sol-gel technique; Volatile organohalogen compounds; NEEDLE TRAP DEVICE; TETRACHLOROETHENE; DICHLOROMETHANE; TRICHLOROETHENE; CHROMATOGRAPHY; EMISSIONS;
D O I
10.1186/s40201-014-0123-5
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A green, environmental friendly and sensitive method for determination of volatile organohalogen compounds was described in this paper. The method is based on a homemade sol-gel single-walled carbon nanotube/silica composite coated solid-phase microextraction to develop for sampling and analysis of Carbon tetrachloride, Benzotrichloride, Chloromethyl methyl ether and Trichloroethylene in air. Application of this method was investigated under different laboratory conditions. Predetermined concentrations of each analytes were prepared in a home-made standard chamber and the influences of experimental parameters such as temperature, humidity, extraction time, storage time, desorption temperature, desorption time and the sorbent performance were investigated. Under optimal conditions, the use of single-walled carbon nanotube/silica composite fiber showed good performance, high sensitive and fast sampling of volatile organohalogen compounds from air. For linearity test the regression correlation coefficient was more than 98% for analyte of interest and linear dynamic range for the proposed fiber and the applied Gas Chromatography-Flame Ionization Detector technique was from 1 to 100 ngmL(-1). Method detection limits ranged between 0.09 to 0.2 ngmL(-1) and method quantification limits were between 0.25 and 0.7 ngmL(-1). Single-walled carbon nanotube/silica composite fiber was highly reproducible, relative standard deviations were between 4.3 to 11.7 percent.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Solid-phase microextraction fiber development for sampling and analysis of volatile organohalogen compounds in air
    Seyed Ghavameddin Attari
    Abdolrahman Bahrami
    Farshid Ghorbani Shahna
    Mahmoud Heidari
    [J]. Journal of Environmental Health Science and Engineering, 12
  • [2] Air sampling and analysis of volatile organic compounds with solid phase microextraction
    Koziel, J.A.
    Pawliszyn, J.
    [J]. Journal of the Air and Waste Management Association, 2001, 51 (02): : 173 - 184
  • [3] Air sampling and analysis of volatile organic compounds with solid phase microextraction
    Koziel, JA
    Pawliszyn, J
    [J]. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2001, 51 (02) : 173 - 184
  • [4] Potential of solid-phase microextraction fibers for the analysis of volatile organic compounds in air
    Tuduri, L
    Desauziers, V
    Fanlo, JL
    [J]. JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2001, 39 (12) : 521 - 529
  • [5] Solid-phase microextraction method development for headspace analysis of volatile flavor compounds
    Roberts, DD
    Pollien, P
    Milo, C
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2000, 48 (06) : 2430 - 2437
  • [6] A simple calibration procedure for volatile organic compounds sampling in air with adsorptive solid-phase microextraction fibres
    Tuduri, L
    Desauziers, V
    Fanlo, JL
    [J]. ANALYST, 2003, 128 (08) : 1028 - 1032
  • [7] Solid-Phase Microextraction Arrow for the Sampling of Volatile Organic Compounds in Milk Samples
    Manousi, Natalia
    Rosenberg, Erwin
    Zachariadis, George A.
    [J]. SEPARATIONS, 2020, 7 (04) : 1 - 12
  • [8] Dynamic air sampling of volatile organic compounds using solid phase microextraction
    Razote, E
    Jeon, I
    Maghirang, R
    Chobpattana, W
    [J]. JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART B-PESTICIDES FOOD CONTAMINANTS AND AGRICULTURAL WASTES, 2002, 37 (04) : 365 - 378
  • [9] Dynamic versus static sampling for the quantitative analysis of volatile organic compounds in air with polydimethylsiloxane - Carboxen solid-phase microextraction fibers
    Tuduri, L
    Desauziers, V
    Fanlo, JL
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2002, 963 (1-2) : 49 - 56
  • [10] Optimization of Solid-Phase Microextraction Sampling for Analysis of Volatile Compounds Emitted from Oestrous Urine of Mares
    Mozuraitis, Raimondas
    Buda, Vincas
    Borg-Karlson, Anna-Karin
    [J]. ZEITSCHRIFT FUR NATURFORSCHUNG SECTION C-A JOURNAL OF BIOSCIENCES, 2010, 65 (1-2): : 127 - 133