Biomarker reproducibility in exhaled breath condensate collected with different condensers

被引:55
|
作者
Rosias, P. P. [1 ]
Robroeks, C. M. [1 ]
Kester, A. [3 ]
den Hartog, G. J.
Wodzig, W. K. [2 ]
Rilkers, G. T. [5 ]
Zimmermann, L. J. [4 ]
van Schayck, C. P.
Joebsis, Q. [1 ]
Dompeling, E. [1 ]
机构
[1] Univ Hosp Maastricht, Caphri Res Inst, Dept Pediat Pulm, NL-6202 AZ Maastricht, Netherlands
[2] Univ Hosp Maastricht, NL-6202 AZ Maastricht, Netherlands
[3] Univ Hosp Maastricht, Caphri Res Inst, Dept Methodol & Stat, NL-6202 AZ Maastricht, Netherlands
[4] Univ Hosp Maastricht, Caphri Res Inst, Dept Gen Practice, NL-6202 AZ Maastricht, Netherlands
[5] Univ Utrecht, Wilhelmina Childrens Hosp, Med Ctr, Dept Immunol, Utrecht, Netherlands
关键词
condenser; cytokines; exhaled breath condensates; hydrogen peroxide; 8-isoprostane; multiplex array;
D O I
10.1183/09031936.00073207
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Optimal collection and analysis of exhaled breath condensate (EBC) are prerequisites for standardisation and reproducibility of assessments. The present study aimed to assess reproducibility of EBC volume, hydrogen peroxide (H2O2), 8-isoprostane and cytokine measurements using different condensers, including a newly developed glass condenser. At four points in time, 30 healthy subjects performed sequential EBC collections randomly using the following four condensers: glass, silicone, EcoScreen (R) (Erich Jaeger GmbH, Hoechberg, Germany) and an optimised glass condenser. In small EBC samples, H2O2 was measured by spectrophotometer, 8-isoprostane by enzyme immunoassay, and cytokines by multiplexed xMAP (R) technology (Luminex Corporation, Austin, TX, USA). The optimised glass condenser yielded significantly more EBC volume (median 2,025 mu L, interquartile range 1,600-2,525). The reproducibility of EBC volume, yielded by the new glass condenser, was comparable with EcoScreer (R) (19-20 coefficients of variation (CV)%), but was significantly better compared with silicone and glass (29-37 CV%). The new condenser was associated with significantly more detections of H2O2, 8-isoprostane, interieukin-2, -4, -5 and -13, and tumour necrosis factor-a. Isoprostane concentrations were significantly higher using the new condenser, whereas H2O2 and cytokine concentrations were not. Reproducibility of biomarkers was equally variable for all condenser types. In conclusion, significantly more exhaled breath condensate volume and biomarker detections were found using the optimised glass condenser, including higher 8-isoprostane levels. However, biomarker reproducibility in exhaled breath condensate in healthy adults was not influenced by the type of condenser.
引用
收藏
页码:934 / 942
页数:9
相关论文
共 50 条
  • [41] Collection of exhaled breath and exhaled breath condensate in veterinary medicine. A review
    Zollinger, E.
    Clauss, M.
    Steinmetz, H. W.
    Hatt, J. -M.
    VETERINARY QUARTERLY, 2006, 28 (03) : 105 - 117
  • [42] The Effect of Different Periods of Argon Deaeration on Exhaled Breath Condensate pH
    Prieto, Luis
    Orosa, Belen
    Barato, Desiree
    Marin, Julio
    JOURNAL OF ASTHMA, 2011, 48 (04) : 319 - 323
  • [43] Exhaled Breath Condensate Delusion or Dilution?
    Effros, Richard M.
    CHEST, 2010, 138 (03) : 471 - 472
  • [44] Assessment of Exhaled Breath Condensate pH
    Effros, Richard M.
    Casaburi, Richard
    Porszasz, Janos
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2011, 183 (07) : 952 - 952
  • [45] Effect of different periods of argon deaeration on exhaled breath condensate pH
    Barato, D.
    Orosa, B.
    Prieto, L.
    Marin, J.
    ALLERGY, 2011, 66 : 577 - 577
  • [46] Exhaled breath biomarker sensing
    Vasilescu, Alina
    Hrinczenko, Borys
    Swain, Greg M.
    Peteu, Serban F.
    BIOSENSORS & BIOELECTRONICS, 2021, 182
  • [47] Malondialdehyde in exhaled breath condensate and urine as a biomarker of air pollution induced oxidative stress
    Gong, Jicheng
    Zhu, Tong
    Kipen, Howard
    Wang, Guangfa
    Hu, Min
    Ohman-Strickland, Pamela
    Lu, Shou-En
    Zhang, Lin
    Wang, Yuedan
    Zhu, Ping
    Rich, David Q.
    Diehl, Scott R.
    Huang, Wei
    Zhang, Junfeng
    JOURNAL OF EXPOSURE SCIENCE AND ENVIRONMENTAL EPIDEMIOLOGY, 2013, 23 (03) : 322 - 327
  • [48] High Resolution Metabolomics on Exhaled Breath Condensate to Discover Lung Cancer's Biomarker
    Park, Chang Young
    Khan, Adnan
    Pamungkas, Aryo
    Sim, Eun Jung
    Kang, Kyung Ho
    Lee, Sung Yong
    JOURNAL OF THORACIC ONCOLOGY, 2017, 12 (01) : S629 - S629
  • [49] A mass spectrometric method to simultaneously measure a biomarker and dilution marker in exhaled breath condensate
    Esther, Charles R., Jr.
    Jasin, H. Matias
    Collins, Leonard B.
    Swenberg, James A.
    Boysen, Gunnar
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2008, 22 (05) : 701 - 705
  • [50] Malondialdehyde in exhaled breath condensate and urine as a biomarker of air pollution induced oxidative stress
    Jicheng Gong
    Tong Zhu
    Howard Kipen
    Guangfa Wang
    Min Hu
    Pamela Ohman-Strickland
    Shou-En Lu
    Lin Zhang
    Yuedan Wang
    Ping Zhu
    David Q Rich
    Scott R Diehl
    Wei Huang
    Junfeng (Jim) Zhang
    Journal of Exposure Science & Environmental Epidemiology, 2013, 23 : 322 - 327