Biomarker reproducibility in exhaled breath condensate collected with different condensers

被引:55
|
作者
Rosias, P. P. [1 ]
Robroeks, C. M. [1 ]
Kester, A. [3 ]
den Hartog, G. J.
Wodzig, W. K. [2 ]
Rilkers, G. T. [5 ]
Zimmermann, L. J. [4 ]
van Schayck, C. P.
Joebsis, Q. [1 ]
Dompeling, E. [1 ]
机构
[1] Univ Hosp Maastricht, Caphri Res Inst, Dept Pediat Pulm, NL-6202 AZ Maastricht, Netherlands
[2] Univ Hosp Maastricht, NL-6202 AZ Maastricht, Netherlands
[3] Univ Hosp Maastricht, Caphri Res Inst, Dept Methodol & Stat, NL-6202 AZ Maastricht, Netherlands
[4] Univ Hosp Maastricht, Caphri Res Inst, Dept Gen Practice, NL-6202 AZ Maastricht, Netherlands
[5] Univ Utrecht, Wilhelmina Childrens Hosp, Med Ctr, Dept Immunol, Utrecht, Netherlands
关键词
condenser; cytokines; exhaled breath condensates; hydrogen peroxide; 8-isoprostane; multiplex array;
D O I
10.1183/09031936.00073207
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Optimal collection and analysis of exhaled breath condensate (EBC) are prerequisites for standardisation and reproducibility of assessments. The present study aimed to assess reproducibility of EBC volume, hydrogen peroxide (H2O2), 8-isoprostane and cytokine measurements using different condensers, including a newly developed glass condenser. At four points in time, 30 healthy subjects performed sequential EBC collections randomly using the following four condensers: glass, silicone, EcoScreen (R) (Erich Jaeger GmbH, Hoechberg, Germany) and an optimised glass condenser. In small EBC samples, H2O2 was measured by spectrophotometer, 8-isoprostane by enzyme immunoassay, and cytokines by multiplexed xMAP (R) technology (Luminex Corporation, Austin, TX, USA). The optimised glass condenser yielded significantly more EBC volume (median 2,025 mu L, interquartile range 1,600-2,525). The reproducibility of EBC volume, yielded by the new glass condenser, was comparable with EcoScreer (R) (19-20 coefficients of variation (CV)%), but was significantly better compared with silicone and glass (29-37 CV%). The new condenser was associated with significantly more detections of H2O2, 8-isoprostane, interieukin-2, -4, -5 and -13, and tumour necrosis factor-a. Isoprostane concentrations were significantly higher using the new condenser, whereas H2O2 and cytokine concentrations were not. Reproducibility of biomarkers was equally variable for all condenser types. In conclusion, significantly more exhaled breath condensate volume and biomarker detections were found using the optimised glass condenser, including higher 8-isoprostane levels. However, biomarker reproducibility in exhaled breath condensate in healthy adults was not influenced by the type of condenser.
引用
收藏
页码:934 / 942
页数:9
相关论文
共 50 条
  • [1] Reproducibility of exhaled breath condensate markers
    Chow, S.
    Yates, D. H.
    Thomas, P. S.
    EUROPEAN RESPIRATORY JOURNAL, 2008, 32 (04) : 1124 - 1126
  • [2] Periostin in exhaled breath condensate as a biomarker of different severe asthma phenotypes
    Scioscia, Giulia
    Cotugno, Grazia
    Soccio, Piera
    Lacedonia, Donato
    Barbaro, Maria Pia Foschino
    Carpagnano, Giovanna Elisiana
    EUROPEAN RESPIRATORY JOURNAL, 2017, 50
  • [3] Evaluation of exhaled breath condensate pH as a biomarker for COPD
    MacNee, William
    Rennard, Stephen I.
    Hunt, John F.
    Edwards, Lisa D.
    Miller, Bruce E.
    Locantore, Nicholas W.
    Tal-Singer, Ruth
    RESPIRATORY MEDICINE, 2011, 105 (07) : 1037 - 1045
  • [4] Exhaled breath condensate
    Griese, M
    PEDIATRIC PULMONOLOGY, 2004, : 14 - 15
  • [5] Exhaled breath condensate
    Becher, G
    DISEASE MARKERS IN EXHALED BREATH: BASIC MECHANISMS AND CLINICAL APPLICATIONS, 2002, 346 : 383 - 386
  • [6] Urates in exhaled breath condensate as a biomarker of control in childhood asthma
    Navratil, Marta
    Plavec, Davor
    Erceg, Damir
    Lokas, Sandra Bulat
    Zivkovic, Jelena
    Turkalj, Mirjana
    JOURNAL OF ASTHMA, 2015, 52 (05) : 437 - 446
  • [7] Exhaled NO and breath condensate
    Baraldi, Eugenio
    Carraro, Silvia
    PAEDIATRIC RESPIRATORY REVIEWS, 2006, 7 : S20 - S22
  • [8] Reproducibility of exhaled breath condensate pH in chronic obstructive pulmonary disease
    Borrill, Z
    Starkey, C
    Vestbo, J
    Singh, D
    EUROPEAN RESPIRATORY JOURNAL, 2005, 25 (02) : 269 - 274
  • [9] Determination of ELISA reproducibility to detect protein markers in exhaled breath condensate
    Nunez-Naveira, Laura
    Marinas-Pardo, Luis A.
    Amor-Carro, Oscar
    Montero-Martinez, Carmen
    JOURNAL OF BREATH RESEARCH, 2012, 6 (04)
  • [10] Malondialdehyde in plasma and exhaled breath condensate collected from ventilated infants
    Morini, F
    Muller, W
    Jaffe, A
    Peters, MJ
    Goldman, A
    Pierro, A
    Eaton, S
    PEDIATRIC RESEARCH, 2005, 58 (02) : 398 - 398