The physiologic effects of a new generation conducted electrical weapon on human volunteers at rest

被引:5
|
作者
Ho, Jeffrey D. [1 ]
Dawes, Donald M. [2 ]
Kunz, Sebastian N. [3 ]
Klein, Lauren R. [1 ]
Driver, Brian E. [1 ]
DeVries, Paige A. [1 ]
Jones, Gregg A. [1 ]
Stang, Jamie L. [1 ]
机构
[1] Hennepin Healthcare, Minneapolis, MN USA
[2] Lompoc Valley Med Ctr, Lompoc, CA 93436 USA
[3] Ulm Univ, Inst Forens Med, Ulm, Germany
关键词
Axon; CEW; Conducted electrical weapon; Conducted energy weapon; Physiology; TASER; INCREASED HEMATOCRIT; TASER; EXPOSURE; DEVICES;
D O I
10.1007/s12024-020-00249-w
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
Axon Enterprise, Inc. (Axon) released its newest generation conducted electrical weapon (CEW), the T7, in October 2018. In order to compare the effects of this new CEW to prior generations, we used our previously described methodology to study the physiologic effects of CEWs on human volunteers at rest. This was a prospective, observational study of human subjects consisting of two parts. Part 1 was testing a single cartridge (2-probe) exposure. Subjects received a 10-s exposure from the T7 to the back with a 30 cm (12 in.) spread between the two probes. Part 2 was testing a simultaneous two-cartridge (4-probe) exposure. Subjects received a 10-s exposure from the T7 to the back with two cartridges with a 10 cm (4 in.) spread between each probe pair. The probe pairs were arranged cephalad to caudal such that the distance between the top probe of the first cartridge and the bottom probe of the second cartridge was 30 cm (12 in.). Vital signs were measured immediately before and after the exposure. Continuous spirometry was performed. ECG monitoring was performed immediately before and after the exposure. Venous pH, lactate, potassium, CK, catecholamines, and troponin were measured before and immediately after the exposure, at 1-h post-exposure, and again at 24 h. 11 subjects completed part 1 of the study. 9 subjects completed part 2 of the study. No subjects had a dysrhythmia or morphology change in the surface ECG. There were no statistical changes in vital signs pre- and post-exposure. While subjects did not have a statistical change in spirometry parameters pre-exposure to exposure except for a small drop in PETCO2, there was an increase in minute ventilation after the exposure that could have several explanations. A similar pattern was seen with prior generation weapons. No subject had elevated troponin levels. Other blood parameters including venous pH, lactate, potassium, CK, and catecholamines had changes similar to prior generation weapons. Comparison of the data for the single-cartridge exposures against the simultaneous two-cartridge exposures yielded no difference in vital signs, but the minute ventilation was higher for the two-cartridge exposures. The blood data, where there was a difference, was mixed. In our study, the physiologic effects of the Axon T7 are modest, consistent with the electrically-induced motor nerve-driven muscle contraction, and were similar to prior generation weapons.
引用
收藏
页码:406 / 414
页数:9
相关论文
共 44 条
  • [11] Respiratory effect of prolonged electrical weapon application on human volunteers
    Ho, Jeffrey D.
    Dawes, Donald M.
    Bultman, Laura L.
    Thacker, Jenny L.
    Skinner, Lisa D.
    Bahr, Jennifer M.
    Johnson, Mark A.
    Miner, James R.
    ACADEMIC EMERGENCY MEDICINE, 2007, 14 (03) : 197 - 201
  • [12] Penetration Depths of Conducted Electrical Weapon Probes Into Human Skull Phantoms
    Bolliger, Stephan Andreas
    Gort, Silvan
    Kaelin, Beat
    Barrera, Vera
    Thali, Michael Josef
    Martinez, Rosa Maria
    AMERICAN JOURNAL OF FORENSIC MEDICINE AND PATHOLOGY, 2019, 40 (02): : 102 - 107
  • [13] Human Health Risks of Conducted Electrical Weapon Exposure A Systematic Review
    Baliatsas, Christos
    Gerbecks, Jenny
    Duckers, Michel L. A.
    Yzermans, C. Joris
    JAMA NETWORK OPEN, 2021, 4 (02)
  • [14] Immediate cardiovascular effects of the Taser X26 conducted electrical weapon
    Bozeman, W. P.
    Barnes, D. G., Jr.
    Winslow, J. E., III
    Johnson, J. C., III
    Phillips, C. H.
    Alson, R.
    EMERGENCY MEDICINE JOURNAL, 2009, 26 (08) : 567 - 570
  • [15] A TASER conducted electrical weapon with cardiac biomonitoring capability: Proof of concept and initial human trial
    Stopyra, Jason P.
    Ritter, Samuel I.
    Beatty, Jennifer
    Johnson, James C.
    Kleiner, Douglas M.
    Winslow, James E., III
    Gardner, Alison R.
    Bozeman, William P.
    JOURNAL OF FORENSIC AND LEGAL MEDICINE, 2016, 43 : 48 - 52
  • [16] The neuroendocrine effects of the TASER X26 conducted electrical weapon as compared to oleoresin capsicum
    Dawes, D. M.
    Ho, J. D.
    Miner, J. R.
    Johnson, M.
    ANNALS OF EMERGENCY MEDICINE, 2007, 50 (03) : S132 - S133
  • [17] New Conducted Electrical Weapons: Thoracic Cage Shielding Effects
    Panescu, Dorin
    Kroll, Mark W.
    Brave, Michael A.
    2017 39TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2017, : 2191 - 2196
  • [18] EFFECTS OF A NEW HUMAN RESPIRATORY VIRUS IN VOLUNTEERS
    BRADBURNE, AF
    BYNOE, ML
    TYRRELL, DAJ
    BMJ-BRITISH MEDICAL JOURNAL, 1967, 3 (5568): : 767 - +
  • [19] The neurocognitive effects of a conducted electrical weapon compared to high intensity interval training and alcohol intoxication - implications for Miranda and consent
    Dawes, D.
    Ho, J.
    Vincent, A. S.
    Nystrom, P.
    Driver, B.
    JOURNAL OF FORENSIC AND LEGAL MEDICINE, 2018, 53 : 51 - 57
  • [20] Cardiac Safety Using a Swine Surrogate Model for a New Concept Conducted Electrical Weapon—The TASER® T10
    D. M. Dawes
    J. D. Ho
    S. N. Kunz
    H. R. Halperin
    S. K. Knack
    Journal of Transformative Technologies and Sustainable Development, 9 (1)