A condition monitoring and fault detection in the windings of power transformer using impulse frequency response analysis

被引:1
|
作者
Kumar, Ritesh [1 ]
Vaijayanthi, Adavelli [1 ]
Deshmukh, Ram [1 ]
Vedik, B. [1 ]
Shiva, Chandan Kumar [1 ]
机构
[1] SR Univ, Dept Elect & Elect Engn, Warangal, Andhra Pradesh, India
关键词
Power transformer; Fault detection; Turn-to-turn fault; Condition monitoring; Frequency response analysis; DIAGNOSIS;
D O I
10.1007/s13198-022-01619-z
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The power transformer is one of the most important pieces of equipment and plays a vital role in the power system. Failure of the transformer may cause an outage of the power supply, which may affect the utility. The main reasons for the transformer's failure include insulation degradation and/or deformation of its windings which occurs due to the transient phenomenon and overloading conditions, and it leads to the turn-to-turn fault (TTF) in windings of the transformer. This TTF in turn may lead to a catastrophic fault in the windings of the transformer. Frequency response analysis (FRA), commonly, used an offline method to detect these faults, however, leads to an outage of power supply. The main aim of this paper is to diagnosis the transformer windings and detect the early faults if any. In this paper, two methods are simulated and discussed, namely impulse frequency response analysis (IFRA) and Lightning impulse analysis (LIA). These methods are capable of diagnosis winding deformation and short circuit faults on live transformers. An injecting of the impulse signal into the electrical model of a high voltage power transformer winding through the bushing capacitive coupling circuit are studied. The obtained simulation results are observed by comparing the obtained frequency response for a healthy and faulty condition for both online and offline transformers.
引用
收藏
页码:2062 / 2074
页数:13
相关论文
共 50 条
  • [31] Cross Test Comparison in Transformer Windings Frequency Response Analysis
    Banaszak, Szymon
    Szoka, Wojciech
    ENERGIES, 2018, 11 (06)
  • [32] Detection of Power Transformer Bushing Faults and Oil Degradation using Frequency Response Analysis
    Hashemnia, Naser
    Abu-Siada, A.
    Islam, S.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2016, 23 (01) : 222 - 229
  • [33] Condition Monitoring of Distribution Transformer's Mechanical Parts using Sweep Frequency Response Analysis (SFRA)
    Ab Ghani, Sharin
    Thayoob, Yasmin Hanum Md
    Ghazali, Young Zaidey Yang
    Khiar, Mohd Shahril Ahmad
    Chairul, Imran Sutan
    INTERNATIONAL TRIBOLOGY CONFERENCE MALAYSIA 2013, 2013, 68 : 469 - 476
  • [34] The analysis of sensitivity of diagnostic models for the monitoring of a transformer windings condition under load
    Beliaev, V.
    Obodovskij, V.
    Panenko, H.
    Beliaev, V. (bel_vk@ua.fm), 1600, Institute of Electrodynamics, Peremogy 56,, Kyiv-57,, 03680, Ukraine : 81 - 87
  • [35] Modeling and Diagnostic Transformer Condition Using Sweep Frequency Response Analysis
    Purnomoadi, A. P.
    Fransisco, D.
    ICPADM 2009: PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2009, : 1059 - +
  • [36] A New Method for Analysing Transformer Condition Using Frequency Response Analysis
    Small, Belinda J.
    Abu-Siada, A.
    2011 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2011,
  • [38] Analysis of High Frequency Power Transformer Windings for Leakage Inductance Calculation
    Ferreira da Luz, Mauricio Valencia
    Dular, Patrick
    ADVANCED COMPUTER TECHNIQUES IN APPLIED ELECTROMAGNETICS, 2008, 30 : 307 - 312
  • [39] Transformer Fault Diagnosis using Frequency Response Analysis - Practical Studies
    Firoozi, Hormatollah
    Kharezi, Mohammad
    Rahimpour, Hossein
    Shams, Mehdi
    2011 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2011,
  • [40] Modeling of transformer's windings frequency response
    Banaszak, Szymon