One-year follow-up of conduction disturbances following transcatheter aortic valve implantation

被引:9
|
作者
Salizzoni, Stefano [1 ]
Anselmino, Matteo [2 ]
Fornengo, Cristina [2 ]
Giordana, Francesca [2 ]
La Torre, Michele [1 ]
Moretti, Claudio [2 ]
D'Amico, Maurizio [3 ]
Omede, Pierluigi [2 ]
Marra, Sebastiano [3 ]
Rinaldi, Mauro [1 ]
Gaita, Fiorenzo [2 ]
机构
[1] Univ Turin, Dept Surg Sci, Div Cardiac Surg, Turin, Italy
[2] Univ Turin, Dept Med Sci, Div Cardiol, Turin, Italy
[3] Citta Salute & Sci Hosp, Div Cardiol, Turin, Italy
关键词
aortic stenosis; complications; conduction disturbances; follow-up; pacemaker; transcatheter aortic valve implantation; BUNDLE-BRANCH BLOCK; ATRIOVENTRICULAR-BLOCK; MEDTRONIC COREVALVE; PERMANENT PACEMAKER; HEART-BLOCK; REPLACEMENT; PREDICTORS; STENOSIS; SYSTEM; ABNORMALITIES;
D O I
10.2459/JCM.0000000000000179
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
AimsTo describe the postprocedural and 1-year follow-up incidence of heart conduction disturbances in patients with severe symptomatic aortic stenosis undergoing transcatheter aortic valve implantation (TAVI).MethodsNinety-five patients were enrolled from 2008 to 2011 (mean age 81.87.2 years, 63.1% women). Clinical and ECG data were recorded at admission, discharge, and 3, 6 and 12 months following TAVI.ResultsFifty-seven Edwards SAPIEN (31 transapical, 26 transfemoral) and 38 transfemoral CoreValve implants were used. Two (2.1%) patients died during the procedure and 11 (11.6%) patients received a pacemaker prior to discharge (7 CoreValve, 3 transapical, 1 transfemoral SAPIEN; P=0.18). Among the surviving patients not receiving a pacemaker, TAVI increased the PQ interval (176 +/- 29 vs. 188 +/- 36 ms; P=0.001), QRS width (90 +/- 15 vs. 108 +/- 26 ms; P<0.001), and first-grade atrioventricular block (17 vs. 29%; P<0.001). Postprocedural complete left bundle branch block was reported most in transapical (from 10 to 36%; P=0.01) and CoreValve (from 8 to 64%; P<0.001) recipients compared to the transfemoral SAPIEN group. At the 12-month follow-up, 24 (25.3%) patients had died [two (2.1%) sudden deaths] and four (4.2%) required pacemaker implantation. Among the survivors not receiving a pacemaker at the 1-year follow-up, the PQ interval (178 +/- 27 vs. 188 +/- 36ms; P=0.39) remained unchanged in the ECG, whereas the QRS width (100 +/- 22 vs. 108 +/- 26 ms; P=0.008) decreased compared to measurements taken at discharge.ConclusionConduction disturbances following TAVI primarily develop during hospitalization and subsequently stabilize. However, the small percentage of patients suffering sudden death or pacemaker implantation requires attention.
引用
收藏
页码:296 / 302
页数:7
相关论文
共 50 条
  • [11] Five-year follow-up after transcatheter aortic valve implantation for symptomatic aortic stenosis
    Zahn, Ralf
    Werner, Nicolas
    Gerckens, Ulrich
    Linke, Axel
    Sievert, Horst
    Kahlert, Philipp
    Hambrecht, Rainer
    Sack, Stefan
    Abdel-Wahab, Mohamed
    Hoffmann, Ellen
    Zeymer, Uwe
    Schneider, Steffen
    HEART, 2017, 103 (24) : 1970 - 1976
  • [12] One-Year Outcomes of Transcatheter Aortic Valve Implantation Using the Direct Aortic Approach
    Bruschi, Giuseppe
    Branny, Marian
    Schiltgen, Molly
    Ettori, Federica
    Marcheix, Bertrand
    Amrane, Hafid
    Bushnaq, Hasan
    Tan, M. Erwin S. H.
    Trivedi, Uday
    Branny, Piotr
    Klugmann, Silvio
    Coletti, Giuseppe
    Dumonteil, Nicolas
    Porta, Fabiano
    Nordell, Anna
    Moat, Neil
    ANNALS OF THORACIC SURGERY, 2017, 103 (05): : 1434 - 1442
  • [13] TRICUSPID VALVE COMMISSUROTOMY WITH A ONE-YEAR FOLLOW-UP
    TRACE, HD
    BAILEY, CP
    WENDKOS, MH
    AMERICAN HEART JOURNAL, 1954, 47 (04) : 613 - 618
  • [14] Transapical transcatheter aortic valve implantation: Follow-up to 3 years
    Ye, Jian
    Cheung, Anson
    Lichtenstein, Samuel V.
    Nietlispach, Fabian
    Albugami, Saad
    Masson, Jean-Bernard
    Thompson, Christopher R.
    Munt, Brad
    Moss, Robert
    Carere, Ronald G.
    Jamieson, W. R. Eric
    Webb, John G.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2010, 139 (05): : 1107 - U27
  • [15] Safety, efficacy, and clinical outcomes of transcatheter tricuspid valve replacement: One-year follow-up
    Mao, Yu
    Li, Lanlan
    Liu, Yang
    Zhai, Mengen
    Ma, Yanyan
    Xu, Chennian
    Jin, Ping
    Yang, Jian
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [16] First Egyptian experience of Transcatheter Aortic Valve Implantation: Immediate results and one year follow up
    Khashaba, Ahmed A.
    Adel, Walaa
    Roshdi, Alaa
    Gafar, Ahmed
    Essam, Sherif
    Algendy, Mohammad A. S.
    EGYPTIAN HEART JOURNAL, 2014, 66 (01): : 17 - 21
  • [17] Influence of deep implantation on conduction disturbances after transcatheter aortic valve implantation
    Saad M.
    Klaus Y.
    Buhse P.
    Puehler T.
    Lutter G.
    Seoudy H.
    Frank D.
    Herzschrittmachertherapie + Elektrophysiologie, 2021, 32 (3) : 371 - 379
  • [18] Pacemaker dependency at 2-month follow-up after permanent pacemaker implantation caused by transcatheter aortic valve implantation-induced conduction disturbances
    van Mourik, Martijn
    Kooistra, Nynke
    Kooiman, Kirsten
    Vendrik, Jeroen
    Stella, Pieter
    Baan, Jan
    Henriques, Jose P. S.
    Vis, Marije
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (13) : B190 - B191
  • [19] Transcatheter Valve-in-Valve Aortic Valve Implantation: 16-Month Follow-Up
    Ye, Jian
    Webb, John G.
    Cheung, Anson
    Masson, Jean-Bernard
    Carere, Ronald G.
    Thompson, Christopher R.
    Munt, Brad
    Moss, Robert
    Lichtenstein, Samuel V.
    ANNALS OF THORACIC SURGERY, 2009, 88 (04): : 1322 - 1324
  • [20] ONE-YEAR FOLLOW-UP OF CYSTOID MACULAR EDEMA FOLLOWING INTRAOCULAR LENS IMPLANTATION
    WINSLOW, RL
    TAYLOR, BC
    HARRIS, WS
    OPHTHALMOLOGY, 1978, 85 (02) : 190 - 196