Pressure-drops control strategy in a fixed-bed reactor

被引:4
|
作者
Thalasso, F [1 ]
Razo-Flores, E [1 ]
Ancia, R [1 ]
Naveau, HP [1 ]
Nyns, EJ [1 ]
机构
[1] Univ Catholique Louvain, Bioengn Unit, B-1348 Louvain, Belgium
关键词
biofilter; clogging; biomass; pressure-drops; control;
D O I
10.1016/S0304-3894(00)00319-8
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper presents a strategy to control pressure-drops (head lass) in a biofilter designed according to the "Mist-Foam" concept. This concept is based on the mixing of the gaseous substrate and a liquid nutrient solution with an atomization nozzle to generate a mist passing subsequently through a synthetic polyurethane foam. In this type of bioreactor, the microbial growth reduces progressively the empty bed volume of the biofilter and causes an increase in the pressure-drops. This phenomenon can result in a complete clogging of the biofilter. The strategy of pressure-drops control presented here consists of successive interruption of the liquid flow, automatically controlled, resulting in a drying effect of the biomass. Tested during a 160 days experiment, this system has permitted to reduce and stabilize the pressure-drops in a biofilter in which the carrier exhibited a high likelihood of clogging. (C) 2001 Published by Elsevier Science B.V.
引用
收藏
页码:115 / 122
页数:8
相关论文
共 50 条