First measurement of VUV spectroscopy using 1 m normal incidence spectrometer on HL-2A

被引:4
|
作者
Cui Zhengying [1 ]
Sun Ping [1 ]
Dong Jiafu [1 ]
Huang Yuan [1 ]
Wang Quanming [1 ]
Fu Bingzhong [1 ]
Lu Jie [1 ]
Chen Wei [1 ]
Duan Xuru [1 ]
Ding Xuantong [1 ]
Yang Qingwei [1 ]
Morita, S. [2 ]
机构
[1] SW Inst Phys, Chengdu 610041, Peoples R China
[2] Natl Inst Nat Sci, Natl Inst Fus Sci, Toki, Gifu 5095292, Japan
关键词
VUV spectroscopy; line emission; CCD;
D O I
10.1088/1009-0630/10/3/06
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
A 1 m vacuum ultraviolet (VUV) spectrometer with temporal and spatial resolution was developed for impurity study of HL-2A tokamak. The instrument is equipped with two concave gratings blazed at 80 nm and 150 nm, respectively, and a windowless back-illuminated charge coupled device (CCD) detector of 256 x 1024 pixels. The total wavelength coverage of spectrometer is 30 similar to 320 nm with a spectral resolution of 0.015 nm at a width of entrance slit of 10 mu m. A portion of this range is observed during a plasma discharge with a spectral range of 20 nm. The minimum integration time of the detector system is about 6.7 ms for each frame in a full binning mode. Using a space-resolved slit located between the entrance slit and the grating a radial pro. le on the vertical direction with a range of 400 mm can be obtained. The primary results were successfully obtained with high signal-to-noise ratio and good spectral resolution, which demonstrated the instrument functions very well.
引用
收藏
页码:298 / 301
页数:4
相关论文
共 50 条
  • [1] First Measurement of VUV Spectroscopy Using 1 m Normal Incidence Spectrometer on HL-2A
    崔正英
    孙平
    董贾福
    黄渊
    王全明
    傅炳忠
    卢杰
    陈伟
    段旭如
    丁玄同
    杨青巍
    森田繁
    Plasma Science and Technology, 2008, 10 (03) : 298 - 301
  • [2] First Measurement of VUV Spectroscopy Using 1 m Normal Incidence Spectrometer on HL-2A
    崔正英
    孙平
    董贾福
    黄渊
    王全明
    傅炳忠
    卢杰
    陈伟
    段旭如
    丁玄同
    杨青巍
    森田繁
    Plasma Science and Technology, 2008, (03) : 298 - 301
  • [3] Impurity Measured by VUV Spectrometer and OMA on HL-2A Tokamak
    崔正英
    王全明
    董贾福
    孙平
    李伟
    王恩耀
    Plasma Science & Technology, 2004, (04) : 2359 - 2363
  • [4] Impurity measured by VUV spectrometer and OMA on HL-2A tokamak
    Cui, ZY
    Wang, QM
    Dong, JF
    Sun, P
    Lu, J
    Li, W
    Wang, EY
    PLASMA SCIENCE & TECHNOLOGY, 2004, 6 (04) : 2359 - 2363
  • [5] First neutron spectrometry measurement at the HL-2A Tokamak
    袁熙
    张兴
    谢旭飞
    陈忠靖
    彭星宇
    樊铁栓
    陈金象
    李湘庆
    袁国梁
    杨青魏
    杨进蔚
    Chinese Physics C, 2013, 37 (12) : 58 - 63
  • [6] First neutron spectrometry measurement at the HL-2A Tokamak
    Yuan Xi
    Zhang Xing
    Xie Xu-Fei
    Chen Zhong-Jing
    Peng Xing-Yu
    Fan Tie-Shuan
    Chen Jin-Xiang
    Li Xiang-Qing
    Yuan Guo-Liang
    Yang Qing-Wei
    Yang Jin-Wei
    CHINESE PHYSICS C, 2013, 37 (12)
  • [7] Space-resolved VUV spectroscopy using the 3 m normal incidence spectrometer with back-illuminated CCD detector in the LHD
    Morita, S
    Goto, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2003, 74 (03): : 2036 - 2039
  • [8] First Charge Exchange Recombination Spectroscopy Diagnostic in HL-2A Tokamak
    Han Xiao-Yu
    Duan Xu-Ru
    Yang Li-Mei
    Yu De-Liang
    Zhong Wu-Lv
    Fu Bing-Zhong
    Liu Yong
    Liu Yi
    Yan Long-Wen
    Yang Qing-Wei
    CHINESE PHYSICS LETTERS, 2010, 27 (05)
  • [9] High-speed VUV spectroscopy for edge impurity line emission measurements in HL-2A tokamak
    郑典麟
    张凯
    崔正英
    孙平
    董春凤
    卢平
    傅炳忠
    刘泽田
    石中兵
    杨青巍
    Plasma Science and Technology, 2018, 20 (10) : 79 - 87
  • [10] High-speed VUV spectroscopy for edge impurity line emission measurements in HL-2A tokamak
    Zheng, Dianlin
    Zhang, Kai
    Cui, Zhengying
    Sun, Ping
    Dong, Chunfeng
    Lu, Ping
    Fu, Bingzhong
    Liu, Zetian
    Shi, Zhongbing
    Yang, Qingwei
    PLASMA SCIENCE & TECHNOLOGY, 2018, 20 (10)