Integrating phase change material in building envelopes combined with the earth-to-air heat exchanger for indoor thermal environment regulation

被引:18
|
作者
Guo, Xin [1 ]
Wei, Haibin [2 ]
He, Xiao [1 ]
He, Miao [1 ]
Yang, Dong [1 ]
机构
[1] Chongqing Univ, Sch Civil Engn, Chongqing 400045, Peoples R China
[2] Power China Huadong Engn Co Ltd, Hangzhou 311122, Peoples R China
基金
中国国家自然科学基金;
关键词
Earth-to-air heat exchanger; Phase change material; Storage capacity; Indoor thermal environment; ENERGY; PERFORMANCE; VENTILATION; COMFORT; PCM; TEMPERATURE; SATURATION; OPERATION; RECOVERY; DESIGN;
D O I
10.1016/j.buildenv.2022.109318
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
To utilize the combined effects of earth-to-air heat exchanger (EAHE) and phase change material (PCM) in indoor thermal environment regulation during summer, this study proposes a combination mode, i.e., EAHE-PCM. In this method, EAHE continuously provides cool air to indoor spaces. PCM integrated into building envelopes stores excess cold provided by EAHE at night and transfers it indoors across time. We performed two full-scale comparative experiments (EAHE-PCM combined operation mode and PCM alone operation mode) on typical summer days in hot-summer and cold-winter regions. The results showed that the maximum reduction in the EAHE outlet air temperature and moisture content reached 21.6 & DEG;C and 4.55 g/kg, respectively, inducing an average cooling capacity of approximately 1186.5 W. The use of EAHE decreased the time-averaged PCM internal temperature by 6.0 & DEG;C in 24 h compared to the PCM alone operation mode, thereby activating the phase change process of PCM between 19:54 and 9:45. Therefore, PCM can store excess cold provided by the EAHE via latent heat and transfer it to indoor air through the melting process, resulting in a 157 min lag in the PCM internal temperature rise. When the ambient air temperature varied between 26.3 and 45.2 & DEG;C, the EAHE-PCM combined operation mode decreased the time-averaged indoor air temperature by 6.6 & DEG;C compared to the PCM operation alone, which helped maintain the indoor air temperature within the comfort temperature range of 22-28 & DEG;C for 73% in 24 h, with a peak temperature of 30.6 & DEG;C.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Optimizing the thermal environment of greenhouse with multi-pipe earth-to-air heat exchanger system using the Taguchi method
    Qi, Di
    Liu, Qian
    Zhao, Chuangyao
    Li, Shixiong
    Song, Bingye
    Li, Angui
    APPLIED THERMAL ENGINEERING, 2024, 242
  • [22] EAHX - Earth-to-air heat exchanger: Simplified method and KPI for early building design phases
    Chiesa, Giacomo
    BUILDING AND ENVIRONMENT, 2018, 144 : 142 - 158
  • [23] Field experiments on the effects of an earth-to-air heat exchanger on the indoor thermal environment in summer and winter for a typical hot-summer and cold-winter region
    Wei, Haibin
    Yang, Dong
    Du, Jinhui
    Guo, Xin
    RENEWABLE ENERGY, 2021, 167 : 530 - 541
  • [24] Thermal characterization of a heat exchanger equipped with a combined material of phase change material and metallic foams
    Ferfera, Ratiba Sabrina
    Madani, Brahim
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2020, 148
  • [25] Thermal performance optimization of a semi-nested building coupled with an earth-to-air heat exchanger using iterative Taguchi method
    Lin, Yaolin
    Feng, Haoming
    Yang, Wei
    Hao, Xiaoli
    Tian, Lin
    Yuan, Xingping
    RENEWABLE ENERGY, 2022, 195 : 1275 - 1290
  • [26] Numerical Research and Parametric Study on the Thermal Performance of a Vertical Earth-to-Air Heat Exchanger System
    Zhang, Zhening
    Sun, Jindong
    Zhang, Zhenxing
    Jia, Xinxin
    Liu, Yang
    MATHEMATICAL PROBLEMS IN ENGINEERING, 2021, 2021
  • [27] Numerical investigation of serpentine earth-to-air heat exchanger for passive building heating systems by recovery criteria
    Soroush, Hamed
    Entezari, Soroush
    Lakzian, Esmail
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2022, 53
  • [28] Experimental study on thermal performance improvement of building envelopes by integrating with phase change material in an intermittently heated room
    Li, Yanru
    Zhou, Jing
    Long, Enshen
    Meng, Xi
    SUSTAINABLE CITIES AND SOCIETY, 2018, 38 : 607 - 615
  • [29] A demand-oriented approach for integrating earth-to-air heat exchangers into buildings for achieving year-round indoor thermal comfort
    Yang, Dong
    Wei, Haibin
    Shi, Rui
    Wang, Jilibo
    ENERGY CONVERSION AND MANAGEMENT, 2019, 182 : 95 - 107