Integrating phase change material in building envelopes combined with the earth-to-air heat exchanger for indoor thermal environment regulation

被引:18
|
作者
Guo, Xin [1 ]
Wei, Haibin [2 ]
He, Xiao [1 ]
He, Miao [1 ]
Yang, Dong [1 ]
机构
[1] Chongqing Univ, Sch Civil Engn, Chongqing 400045, Peoples R China
[2] Power China Huadong Engn Co Ltd, Hangzhou 311122, Peoples R China
基金
中国国家自然科学基金;
关键词
Earth-to-air heat exchanger; Phase change material; Storage capacity; Indoor thermal environment; ENERGY; PERFORMANCE; VENTILATION; COMFORT; PCM; TEMPERATURE; SATURATION; OPERATION; RECOVERY; DESIGN;
D O I
10.1016/j.buildenv.2022.109318
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
To utilize the combined effects of earth-to-air heat exchanger (EAHE) and phase change material (PCM) in indoor thermal environment regulation during summer, this study proposes a combination mode, i.e., EAHE-PCM. In this method, EAHE continuously provides cool air to indoor spaces. PCM integrated into building envelopes stores excess cold provided by EAHE at night and transfers it indoors across time. We performed two full-scale comparative experiments (EAHE-PCM combined operation mode and PCM alone operation mode) on typical summer days in hot-summer and cold-winter regions. The results showed that the maximum reduction in the EAHE outlet air temperature and moisture content reached 21.6 & DEG;C and 4.55 g/kg, respectively, inducing an average cooling capacity of approximately 1186.5 W. The use of EAHE decreased the time-averaged PCM internal temperature by 6.0 & DEG;C in 24 h compared to the PCM alone operation mode, thereby activating the phase change process of PCM between 19:54 and 9:45. Therefore, PCM can store excess cold provided by the EAHE via latent heat and transfer it to indoor air through the melting process, resulting in a 157 min lag in the PCM internal temperature rise. When the ambient air temperature varied between 26.3 and 45.2 & DEG;C, the EAHE-PCM combined operation mode decreased the time-averaged indoor air temperature by 6.6 & DEG;C compared to the PCM operation alone, which helped maintain the indoor air temperature within the comfort temperature range of 22-28 & DEG;C for 73% in 24 h, with a peak temperature of 30.6 & DEG;C.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Parametric study on the thermal performance of phase change material-assisted earth-to-air heat exchanger
    Liu, Qinggong
    Huang, Yi
    Ma, Yin
    Peng, Yuanling
    Wang, Yong
    Wang, Yong (cqwangyong@cqu.edu.cn), 1600, Elsevier Ltd (238):
  • [2] Parametric study on the thermal performance of phase change material-assisted earth-to-air heat exchanger
    Liu, Qinggong
    Huang, Yi
    Ma, Yin
    Peng, Yuanling
    Wang, Yong
    ENERGY AND BUILDINGS, 2021, 238
  • [3] Enhancing a vertical earth-to-air heat exchanger system using tubular phase change material
    Liu, Zhengxuan
    Sun, Pengcheng
    Li, Shuisheng
    Yu, Zhun
    El Mankibi, Mohamed
    Roccamena, Letizia
    Yang, Tingting
    Zhang, Guoqiang
    JOURNAL OF CLEANER PRODUCTION, 2019, 237
  • [4] Evaluation of the thermal performance of an earth-to-air heat exchanger (EAHE) in a harmonic thermal environment
    Yang, Dong
    Guo, Yuanhao
    Zhang, Jinpeng
    ENERGY CONVERSION AND MANAGEMENT, 2016, 109 : 184 - 194
  • [5] Multivariant optimization and sensitivity analysis of an experimental vertical earth-to-air heat exchanger system integrating phase change material with Taguchi method
    Liu, Zhengxuan
    Sun, Pengchen
    Xie, Mingjing
    Zhou, Yuekuan
    He, Yingdong
    Zhang, Guoqiang
    Chen, Dachuan
    Li, Shuisheng
    Yan, Zhongjun
    Qin, Di
    RENEWABLE ENERGY, 2021, 173 : 401 - 414
  • [6] Benefits of integrating phase-change material with solar chimney and earth-to-air heat exchanger system for passive ventilation and cooling in summer
    Long, Tianhe
    Li, Wuyan
    Lv, Yifei
    Li, Yongcai
    Liu, Shuli
    Lu, Jun
    Huang, Sheng
    Zhang, Yaya
    JOURNAL OF ENERGY STORAGE, 2022, 48
  • [7] Numerical modelling of a building integrated earth-to-air heat exchanger
    Taurines, Kevin
    Giroux-Julien, Stephanie
    Farid, Mohammed
    Menezo, Christophe
    APPLIED ENERGY, 2021, 296
  • [8] Thermal and environmental assessment of a passive building equipped with an earth-to-air heat exchanger in France
    Thiers, Stephane
    Peuportier, Bruno
    SOLAR ENERGY, 2008, 82 (09) : 820 - 831
  • [9] Experimental and numerical study of a vertical earth-to-air heat exchanger system integrated with annular phase change material
    Liu, Zhengxuan
    Yu, Zhun
    Yang, Tingting
    El Mankibi, Mohamed
    Roccamena, Letizia
    Sun, Ying
    Sun, Pengcheng
    Li, Shuisheng
    Zhang, Guoqiang
    ENERGY CONVERSION AND MANAGEMENT, 2019, 186 : 433 - 449
  • [10] Analysis of an earth-to-air heat exchanger for enhanced residential thermal comfort
    Dewangan, Chandraprakash
    Shukla, Anuj Kumar
    Salhotra, Rahul
    Dewan, Anupam
    ENVIRONMENTAL PROGRESS & SUSTAINABLE ENERGY, 2024, 43 (03)