Assessment of peri-implant defects at titanium and zirconium dioxide implants by means of periapical radiographs and cone beam computed tomography: An in-vitro examination

被引:19
|
作者
Steiger-Ronay, Valerie [1 ]
Krcmaric, Zvonimir
Schmidlin, Patrick R. [1 ]
Sahrmann, Philipp [1 ]
Wiedemeier, Daniel B. [2 ]
Benic, Goran I. [3 ]
机构
[1] Univ Zurich, Clin Prevent Dent Periodontol & Cariol, Ctr Dent Med, Zurich, Switzerland
[2] Univ Zurich, Stat Serv, Ctr Dent Med, Zurich, Switzerland
[3] Univ Zurich, Clin Fixed & Removable Prosthodont & Dent Mat Sci, Ctr Dent Med, Zurich, Switzerland
关键词
bone; bone defect; computed tomography; cone beam computed tomography; dental implant; digital; periapical radiography; peri-implantitis; radiology; scan; titanium; titanium implant; X-ray; zirconium dioxide; zirconium dioxide implant; DENTAL IMPLANTS; BONE LEVEL; ARTIFACTS; ACCURACY; WORKSHOP; DISEASES; CBCT;
D O I
10.1111/clr.13383
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective To test the accuracy of measurement of interproximal peri-implant bone defects at titanium (Ti) and zirconium dioxide (ZrO2) implants by digital periapical radiography (PR) and cone beam computed tomography (CBCT). Material and methods A total of 18 models, each containing one Ti and one ZrO2 implant, were cast in dental stone. Six models each were allocated to following defect groups: A-no peri-implant defect, B-1 mm width defect, C-1.5 mm width defect. The defect width was measured with a digital sliding caliper. Subsequently, the models were scanned by means of PR and CBCT. Three examiners assessed the defect width on PR and CBCT. Wilcoxon signed-rank test and Wilcoxon rank sum test were applied to detect differences between imaging techniques and implant types. Results For PR, the deviation of the defect width measurement (mm) for groups A, B, and C amounted to 0.01 +/- 0.03, -0.02 +/- 0.06, and -0.00 +/- 0.04 at Ti and 0.05 +/- 0.02, 0.01 +/- 0.03, and 0.09 +/- 0.03 at ZrO2 implants. The corresponding values (mm) for CBCT reached 0.10 +/- 0.11, 0.26 +/- 0.05, and 0.24 +/- 0.08 at Ti and 1.07 +/- 0.06, 0.64 +/- 0.37, and 0.54 +/- 0.17 at ZrO2 implants. Except for Ti with defect A, measurements in PR were significantly more accurate in comparison to CBCT (p <= 0.05). Both methods generally yielded more accurate measurements for Ti than for ZrO2. Conclusions The assessment of interproximal peri-implant defect width at Ti and ZrO2 implants was more accurate in PR in comparison to CBCT. Measurements in CBCT always led to an overestimation of the defect width, reaching clinical relevance for ZrO2 implants.
引用
收藏
页码:1195 / 1201
页数:7
相关论文
共 50 条
  • [21] In Vitro Quantitative Evaluation of Postprocessing Filter for Metal Artifact Reduction in Cone Beam Computed Tomography Images of Titanium and Zirconium Dioxide Implants
    Costa, Andre Luiz Ferreira
    Fardim, Karolina A. C.
    Mantoani, Jennifer M.
    Ricardo, Ana Lucia Franco
    Jardini, Maria Aparecida N.
    Orhan, Kaan
    Lopes, Sergio Lucio Pereira de Castro
    BIOMED RESEARCH INTERNATIONAL, 2022, 2022
  • [22] Zirconia implants interfere with the evaluation of peri-implant bone defects in cone beam computed tomography (CBCT) images even with artifact reduction, a pilot study
    Kuusisto, Niina
    Abushahba, Faleh
    Syrjanen, Stina
    Huumonen, Sisko
    Vallittu, Pekka
    Narhi, Timo
    DENTOMAXILLOFACIAL RADIOLOGY, 2023, 52 (08)
  • [23] Efficacy of two radiographic algorithms for detection of peri-implant bone defects on cone-beam computed tomography scans
    Yousefi, Faezeh
    Heidari, Ali
    Ehsani, Azita
    Farhadian, Maryam
    Ehsani, Marzieh
    BMC ORAL HEALTH, 2025, 25 (01):
  • [24] Comparison between different cone -beam computed tomography devices in the detection of mechanically simulated peri-implant bone defects
    Kim, Jun Ho
    Abdala-Junior, Reinaldo
    Munhoz, Luciana
    Cortes, Arthur Rodriguez Gonzalez
    Watanabe, Plauto Christopher Aranha
    Costa, Claudio
    Arita, Emiko Saito
    IMAGING SCIENCE IN DENTISTRY, 2020, 50 (02) : 133 - 139
  • [25] The role of implants and implant prostheses on the accuracy and artifacts of cone-beam computed tomography: an in-vitro study
    Gurjar, Balwant Singh
    Sharma, Vineet
    Paliwal, Jyoti
    Kalla, Rajani
    Meena, Kamal Kumar
    Tahir, Mohammed
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [26] The role of implants and implant prostheses on the accuracy and artifacts of cone-beam computed tomography: an in-vitro study
    Balwant Singh Gurjar
    Vineet Sharma
    Jyoti Paliwal
    Rajani Kalla
    Kamal Kumar Meena
    Mohammed Tahir
    Scientific Reports, 14
  • [27] Evaluation of a metal artifact reduction algorithm and an adaptive image noise optimization filter in the estimation of peri-implant fenestration defects using cone beam computed tomography: an in-vitro study
    Bagis, Nilsun
    Kurt, Mehmet Hakan
    Evli, Cengiz
    Camgoz, Melike
    Atakan, Cemal
    Ozturk, Hilal Peker
    Orhan, Kaan
    ORAL RADIOLOGY, 2022, 38 (03) : 325 - 335
  • [28] Evaluation of a metal artifact reduction algorithm and an adaptive image noise optimization filter in the estimation of peri-implant fenestration defects using cone beam computed tomography: an in-vitro study
    Nilsun Bagis
    Mehmet Hakan Kurt
    Cengiz Evli
    Melike Camgoz
    Cemal Atakan
    Hilal Peker Ozturk
    Kaan Orhan
    Oral Radiology, 2022, 38 : 325 - 335
  • [29] Effect of field of view in the detection of chemically created peri-implant bone defects in bovine ribs using cone beam computed tomography: an in vitro study
    Pinheiro, Lucas Rodrigues
    Gaia, Bruno Felipe
    Oliveira de Sales, Marcelo Augusto
    Umetsubo, Otavio Shoiti
    Santos, Oseas, Jr.
    Paraiso Cavalcanti, Marcelo Gusmao
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2015, 120 (01): : 69 - 77
  • [30] The Impact of Cone-Beam Computed Tomography Exposure Parameters on Peri-Implant Artifacts: A Literature Review
    Sawicki, Pawel
    Zawadzki, Pawel J.
    Regulski, Piotr
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (03)