7 tesla MRI with RF power and field homogeneity comparable to 4 tesla using computational electromagnetics

被引:0
|
作者
Tang, L. [3 ,4 ]
Ibrahim, T. S. [1 ,2 ,3 ,4 ]
机构
[1] Univ Pittsburgh, Dept Radiol, Pittsburgh, PA 15260 USA
[2] Univ Pittsburgh, Dept Bioengn, Pittsburgh, PA 15260 USA
[3] Univ Oklahoma, Sch Elect & Comp Engn, Norman, OK 73019 USA
[4] Univ Oklahoma, Ctr Bioengn, Norman, OK 73019 USA
关键词
MRI; RF coil; transmit array; FDTD; optimization; RF power; B-1; field; coupling; high filed;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In ultrahigh (>= 7 Tesla) field magnetic resonance imaging (MRI), the electromagnetic interactions between the coil, its excitation sources, and the biological load become more significant compared to low MRI applications. Computational electromagnetic (CEM) techniques are currently playing a major role in the evaluation of MRI radiofrequency (RF) coils (commonly now, within ultrahigh field context, referred to as transmit arrays). This work compares the RF power requirements in 4 and 7 Tesla human MRI using CEM. Furthermore, we demonstrate that at ultrahigh MRI, high-quality/homogenous RF excitation fields could be obtained simultaneously with total RF power deposition lower than that achieved at lower field strengths. These results dispel what has been widely accepted from quasistatic approximations, namely that pushing the envelope of MRI field strength results in more RF power requirements and therefore, more RF power absorption in human tissue. This study is presented using the finite difference time domain (FDTD) method and a gradient-based optimization method.
引用
收藏
页码:70 / 75
页数:6
相关论文
共 50 条
  • [21] Assessment of Pial Branches Using 7-Tesla MRI in Cerebral Arterial Disease
    Song, H. -S.
    Kang, C. -K.
    Kim, J. S.
    Park, C. -A.
    Kim, Y. -B.
    Lee, D. H.
    Kang, D. -W.
    Kwon, S. U.
    Cho, Z. -H.
    CEREBROVASCULAR DISEASES, 2010, 29 (04) : 410 - 410
  • [22] IN VIVO MRI OF THE HUMAN TORSO AT 7 TESLA USING MULTI-CHANNEL TRANSMIT
    Ladd, Mark E.
    Umutlu, Lale
    Maderwald, Stefan
    Kinner, Sonja
    Orzada, Stephan
    Nassenstein, Kai
    Brote, Irina
    Quick, Harald
    Schaefer, Lena
    Ladd, Susanne
    Antoch, Gerald
    Kraff, Oliver
    Bitz, Andreas
    Lauenstein, Thomas
    2010 7TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2010, : 572 - 572
  • [23] Morphologic and biometric evaluation of chick embryo eyes in ovo using 7 Tesla MRI
    Tobias Lindner
    Ronja Klose
    Felix Streckenbach
    Thomas Stahnke
    Stefan Hadlich
    Jens-Peter Kühn
    Rudolf F. Guthoff
    Andreas Wree
    Anne-Marie Neumann
    Marcus Frank
    Änne Glass
    Sönke Langner
    Oliver Stachs
    Scientific Reports, 7
  • [24] Neuroanatomical correlates of apathy in ALS using 4 Tesla diffusion tensor MRI
    Woolley, Susan C.
    Zhang, Yu
    Schuff, Norbert
    Weiner, Michael W.
    Katz, Jonathan S.
    AMYOTROPHIC LATERAL SCLEROSIS, 2011, 12 (01): : 52 - 58
  • [25] MR microscopy of the developing upper extremity of the chicken in ovo using 7 Tesla MRI
    Streckenbach, Felix
    Jaeschke, Malte
    Jahns, Nora
    Langner, Inga
    Koenig, Julia
    Wree, Andreas
    Stahnke, Thomas
    Stachs, Oliver
    Frank, Marcus
    Langner, Soenke
    Lindner, Tobias
    ANATOMIA HISTOLOGIA EMBRYOLOGIA, 2023, 52 (03) : 356 - 362
  • [26] Comparison of Incidental Findings in Major Depressive Disorder Versus Healthy Controls Using Ultrahigh Field [7 Tesla] MRI
    Rutter, Sarah
    Solmssen, Charlotte
    Kaye-Kauderer, Halley
    Verma, Gaurav
    Murrough, James
    Delman, Bradley
    Balchandani, Priti
    BIOLOGICAL PSYCHIATRY, 2021, 89 (09) : S180 - S180
  • [27] Morphologic and biometric evaluation of chick embryo eyes in ovo using 7 Tesla MRI
    Lindner, Tobias
    Klose, Ronja
    Streckenbach, Felix
    Stahnke, Thomas
    Hadlich, Stefan
    Kuehn, Jens-Peter
    Guthoff, Rudolf F.
    Wree, Andreas
    Neumann, Anne-Marie
    Frank, Marcus
    Glass, Aenne
    Langner, Soenke
    Stachs, Oliver
    SCIENTIFIC REPORTS, 2017, 7
  • [28] EEG/(f)MRI measurements at 7 Tesla using a new EEG cap ("InkCap")
    Vasios, Christos E.
    Angelone, Leonardo M.
    Purdon, Patrick L.
    Ahveninen, Jyrki
    Belliveau, John W.
    Bonmassar, Giorgio
    NEUROIMAGE, 2006, 33 (04) : 1082 - 1092
  • [29] Ultra-high field MRI reveals mood-related circuit disturbances in depression: a comparison between 3-Tesla and 7-Tesla
    Morris, Laurel S.
    Kundu, Prantik
    Costi, Sara
    Collins, Abigail
    Schneider, Molly
    Verma, Gaurav
    Balchandani, Priti
    Murrough, James W.
    TRANSLATIONAL PSYCHIATRY, 2019, 9 (1)
  • [30] Ultra-High Field MRI of Mood-Related Circuit Disturbances in Depression: A Systematic Comparison Between 3-Tesla and 7-Tesla
    Morris, Laurel
    Kundu, Prantik
    Costi, Sara
    Collins, Abigail
    Schneider, Molly
    Murrough, James
    Verma, Gaurav
    Balchandani, Priti
    NEUROPSYCHOPHARMACOLOGY, 2018, 43 : S135 - S135