Development of a High-Rate Front-End ASIC for X-Ray Spectroscopy and Diffraction Applications

被引:3
|
作者
Vernon, Emerson [1 ,2 ]
De Geronimo, Gianluigi [2 ]
Baldwin, Jonathan [3 ]
Chen, Wei [1 ]
Fried, Jack [1 ]
Giacomini, Gabriele [1 ]
Kuczewski, Anthony [4 ]
Kuczewski, John [1 ]
Mead, Joe [1 ]
Miceli, Antonino [3 ]
Okasinski, John S. [3 ]
Pinelli, Don [1 ]
Quaranta, Orlando [3 ]
Rumaiz, Abdul K. [4 ]
Siddons, Peter [4 ]
Smith, Graham [1 ]
Stanacevic, Milutin [2 ]
Woods, Russell [3 ]
机构
[1] Brookhaven Natl Lab, Instrumentat Div, Upton, NY 11973 USA
[2] SUNY Stony Brook, Dept Elect & Comp Engn, Stony Brook, NY 11794 USA
[3] Argonne Natl Lab, Xray Sci Div, Lemont, IL 60439 USA
[4] Brookhaven Natl Lab, NSLS II, Upton, NY 11973 USA
关键词
Application-specific integrated circuit (ASIC); detector; diffraction (EDX); front end; mixed signal; spectroscopy (XFS); synchrotron applications; DETECTOR;
D O I
10.1109/TNS.2020.2976820
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We developed a new front-end application-specific integrated circuit (ASIC) to upgrade the Maia X-ray microprobe. The ASIC instruments 32 configurable channels that perform either positive or negative charge amplification, pulse shaping, peak amplitude, and time extraction along with buffered analog storage. At a gain of 3.6 V/fC, 1-mu s peaking time, and a temperature of 248 K, an electronic resolution of 13 and 10 e(-) rms was measured with and without a silicon drift detector (SDD) sensor, respectively. A spectral resolution of 170-eV full-width at half-maximum (FWHM) at 5.9 keV was obtained with an Fe-55 source. The channel linearity was better than +/- 1% with rate capabilities up to 40 kcps. The ASIC was fabricated in a commercial 250-nm process with a footprint of 6.3 mm x 3.9 mm and dissipates 167 mW of static power.
引用
收藏
页码:752 / 759
页数:8
相关论文
共 50 条
  • [31] X-ray effects on the noise performances of 0.18 and 0.25 μm CMOS processes for front-end applications
    Manghisoni, M
    Ratti, L
    Traversi, G
    ASTROPARTICLE, PARTICLE AND SPACE PHYSICS , DETECTORS AND MEDICAL PHYSICS APPLICATIONS, 2004, 2 : 646 - 650
  • [32] Development of a compact radiation-hardened low-noise front-end readout ASIC for CZT-based hard X-ray imager
    Gao, W.
    Gan, B.
    Li, X.
    Wei, T.
    Gao, D.
    Hu, Y.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 780 : 15 - 20
  • [33] Development of X-ray CCD camera system with high readout rate using ASIC
    Nakajima, Hiroshi
    Matsuura, Daisuke
    Anabuki, Naohisa
    Miyata, Emi
    Tsunemi, Hiroshi
    Doty, John P.
    Ikeda, Hirokazu
    Katayama, Haruyoshi
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 610 (01): : 78 - 82
  • [34] Development of X-ray CCD camera system with high readout rate using ASIC
    Nakajima, H.
    Matsuura, D.
    Anabuki, N.
    Miyata, E.
    Tsunemi, H.
    Doty, J. P.
    Ikeda, H.
    Katayama, H.
    SPACE TELESCOPES AND INSTRUMENTATION 2008: ULTRAVIOLET TO GAMMA RAY, PTS 1 AND 2, 2008, 7011
  • [35] Assessment of analog pulse processor performance for ultra high-rate x-ray spectroscopy
    Hafizh, Idham
    Carminati, Marco
    Fiorini, Carlo
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 945
  • [36] High-rate X-ray spectroscopy using a silicon drift detector and a charge preamplifier
    Alberti, R.
    Florini, C.
    Longoni, A.
    Soltau, H.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 568 (01): : 106 - 111
  • [37] A compact back-end module for high-rate multielement X-ray spectrometers and γ-ray imagers
    Pullia, A
    Longoni, A
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (03) : 581 - 585
  • [38] Development of a low-noise front-end ASIC for CdTe detectors
    Kawamura, Tenyo
    Orita, Tadashi
    Takeda, Shin'ichiro
    Watanabe, Shin
    Ikeda, Hirokazu
    Takahashi, Tadayuki
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 982 (982):
  • [39] Low-noise multichannel ASIC for high count rate X-ray diffractometry applications
    Szczygiel, R.
    Grybos, P.
    Maj, P.
    Tsukiyama, A.
    Matsushita, K.
    Taguchi, T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 607 (01): : 229 - 232
  • [40] A CMOS detector readout front-end for X-ray digital radiography systems
    Adachi, S
    Tokuda, S
    Ishida, S
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (01) : 249 - 255