Feasibility of percutaneous implantation of transapical endocardial left ventricular pacing electrode for cardiac resynchronization therapy

被引:20
|
作者
Kassai, Imre [1 ]
Friedrich, Orsolya [2 ]
Ratnatunga, Chandi [2 ]
Betts, Timothy R. [2 ]
Mihalcz, Attila [1 ]
Szili-Torok, Tamas [3 ]
机构
[1] Gottsegen Hungarian Inst Cardiol, Dept Cardiac Surg, Budapest, Hungary
[2] John Radcliffe Hosp, Dept Cardiothorac Surg, Oxford OX3 9DU, England
[3] Erasmus MC, Dept Clin Epidemiol, Thoraxctr, Rotterdam, Netherlands
来源
EUROPACE | 2011年 / 13卷 / 11期
关键词
Heart failure; Biventricular pacing; Trans-apical; Percutaneous; HEART-FAILURE; STIMULATION; EXPERIENCE;
D O I
10.1093/europace/eur190
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Failure of coronary sinus lead implantation for resynchronization therapy requires alternative approaches. For such events we have developed a transapical implantation technique as a feasible alternative. We report the outcome of this technique and its evolution from a minithoracotomy to a percutaneous approach. Twenty patients underwent alternative resynchronization therapy with transapical endocardial left ventricular (LV) pacing lead implantation in a multicentre, international study between October 2007 and March 2010. Eighteen patients underwent minithoracotomy and transapical puncture under direct observation. Two recent patients had transthoracic echocardiography- guided percutaneous apical puncture to enter the LV cavity. A 19 or 21 ga needle and two-stage Seldinger dilatation with 4 and 7 Fr sheaths were then used to introduce the lead. In the two patients with closed-chest insertion of the electrode there was no puncture related bleeding or lung damage. Lead dislocation occurred in two minithoracotomy patients. Repositioning was performed without reopening the pleural cavity. One patient developed right-sided implanted cardiac defibrillator lead endocarditis requiring complete system removal. Twelve patients have >1 year follow-up; all have sustained and significant improvement in LV dimensions (diastolic Delta 4.2 +/- 2.9, systolic Delta 7.2 +/- 5.8 mm), ejection fraction (Delta 9.5 +/- 9.6%), and functional status (Delta 1.1 +/- 0.3). Transapical placement of LV endocardial pacing lead is an effective alternative strategy for cardiac resynchronization. A closed-chest, percutaneous approach is feasible and should offer even less invasive intervention.
引用
收藏
页码:1653 / 1657
页数:5
相关论文
共 50 条
  • [21] Video-assisted thoracoscopic implantation of the left ventricular pacing lead for cardiac resynchronization therapy
    Jutley, Rajwinder S.
    Waller, David A.
    Loke, Ian
    Skehan, Douglas
    Ng, Andre
    Stafford, Peter
    Chin, Derek
    Spyt, T. J.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2008, 31 (07): : 812 - 818
  • [22] Optimizing left ventricular pacing configurations for cardiac resynchronization therapy
    Lee, N
    Disch, D
    Tocco, P
    Botteron, GW
    Craddock, H
    Huelsing, DJ
    JOURNAL OF CARDIAC FAILURE, 2005, 11 (06) : S197 - S197
  • [23] Alternative Techniques for Left Ventricular Pacing in Cardiac Resynchronization Therapy
    Mihalcz, Attila
    Kassai, Imre
    Geller, Laszlo
    Szili-Torok, Tamas
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2014, 37 (02): : 255 - 261
  • [24] Endocardial left ventricular pacing for cardiac resynchronization: systematic review and meta-analysis
    Gamble, James Hugo Phillimore
    Herring, Neil
    Ginks, Matthew
    Rajappan, Kim
    Bashir, Yaver
    Betts, Timothy Rider
    EUROPACE, 2018, 20 (01): : 73 - 81
  • [25] Anticoagulant therapy in patients with left ventricular endocardial stimulation for cardiac resynchronization therapy
    Karpenko, I.
    Abramova, A.
    Goriachiy, A.
    Khanafi, M.
    Volkov, D.
    EUROPEAN HEART JOURNAL, 2016, 37 : 641 - 641
  • [26] Transseptal endocardial left ventricular pacing: An alternative technique for coronary sinus lead placement in cardiac resynchronization therapy
    van Gelder, Berry M.
    Scheffer, Mike G.
    Meijer, Albert
    Bracke, Frank A.
    HEART RHYTHM, 2007, 4 (04) : 454 - 460
  • [27] Endocardial left ventricular pacing across the interventricular septum for cardiac resynchronization therapy: Clinical results of a pilot study
    Gamble, James H. P.
    Herring, Neil
    Ginks, Matthew R.
    Rajappan, Kim
    Bashir, Yaver
    Betts, Tim R.
    HEART RHYTHM, 2018, 15 (07) : 1017 - 1022
  • [28] Endocardial Left Ventricular Pacing Improves Cardiac Resynchronization Therapy in Chronic Asynchronous Infarction and Heart Failure Models
    Strik, Marc
    Rademakers, Leonard M.
    van Deursen, Caroline J. M.
    van Hunnik, Arne
    Kuiper, Marion
    Klersy, Catherine
    Auricchio, Angelo
    Prinzen, Frits W.
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2012, 5 (01): : 191 - 200
  • [29] Right ventricular septal pacing as alternative for failed left ventricular lead implantation in cardiac resynchronization therapy candidates
    Alhous, M. Hafez A.
    Small, Gary R.
    Hannah, Andrew
    Hillis, Graham S.
    Frenneaux, Michael
    Broadhursgt, Paul A.
    EUROPACE, 2015, 17 (01): : 94 - 100
  • [30] Right ventricular outflow tract pacing as an alternative to left ventricular pacing in cardiac resynchronization therapy
    Alhous, H.
    Hannah, A.
    Small, G.
    Hillis, G.
    Broadhurst, P.
    SCOTTISH MEDICAL JOURNAL, 2011, 56 (01) : 52 - 52