Monte Carlo calculations of the absorbed dose and energy dependence of plastic scintillators

被引:30
|
作者
Beddar, AS [1 ]
Briere, TM [1 ]
Mourtada, FA [1 ]
Vassiliev, ON [1 ]
Liu, HH [1 ]
Mohan, R [1 ]
机构
[1] Univ Texas, MD Anderson Canc Ctr, Dept Radiat Phys, Div Radiat Oncol, Houston, TX 77030 USA
关键词
Monte Carlo; Burlin cavity theory; plastic scintillation dosimetry; scintillator; water equivalence;
D O I
10.1118/1.1897465
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Detector systems using plastic scintillators can provide instantaneous measurements with high spatial resolution in many applications including small field and high dose gradient field applications. Energy independence and water equivalence are important dosimetric properties that determine whether a detector will be useful in a clinical setting. Using Monte Carlo simulations, we calculated the energy dependence of plastic scintillators when exposed to photon beams in the radiotherapeutic range. These calculations were performed for a detector comprised of a BC-400 plastic scintillator surrounded by a polystyrene wall. Our results showed the plastic scintillation detector to be nearly energy independent over a range of energies from 0.5 to 20 MeV. The ratio of the dose absorbed by the scintillator to that absorbed by water was nearly a constant, approximately equal to 0.98 over the entire energy range of interest. These results confirm the water equivalence of the plastic scintillation detector and are in very good agreement with earlier results obtained using Burlin cavity theory. (c) 2005 American Association of Physicists in Medicine.
引用
收藏
页码:1265 / 1269
页数:5
相关论文
共 50 条
  • [11] Reply to 'Comments on 'Converting absorbed dose to medium to absorbed dose to water for Monte Carlo based photon beam dose calculations''
    Siebers, JV
    Keall, PJ
    Nahum, AE
    Mohan, R
    PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (08): : L18 - L19
  • [12] The Monte Carlo simulation of the absorbed dose in quartz
    Chen, Shaowen
    Liu, Xiaowei
    Zhang, Chunxiang
    Tang, Qiang
    RADIATION MEASUREMENTS, 2009, 44 (5-6) : 626 - 628
  • [13] Monte Carlo-based investigation of absorbed-dose energy dependence of radiochromic films in high energy brachytherapy dosimetry
    Subhalaxmi, Mishra
    Selvam, T. Palani
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (01): : 351 - 362
  • [14] ABSORBED DOSE MEASUREMENTS AT AN 800 GEV PROTON ACCELERATOR - COMPARISON WITH MONTE-CARLO CALCULATIONS
    COSSAIRT, JD
    BUTALA, SW
    GERARDI, MA
    HEALTH PHYSICS, 1985, 49 (01): : 153 - 153
  • [15] ON THE POSSIBILITY OF REAL-TIME MONTE-CARLO CALCULATIONS FOR THE ESTIMATION OF ABSORBED DOSE IN RADIOIMMUNOTHERAPY
    JOHNSON, TK
    VESSELLA, RL
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 1989, 29 (03) : 205 - 210
  • [16] Absorbed Dose Calculations Using Mesh-based Human Phantoms And Monte Carlo Methods
    Kramer, Richard
    XXXIII BRAZILIAN WORKSHOP ON NUCLEAR PHYSICS, 2011, 1351
  • [17] ABSORBED DOSE MEASUREMENTS AT AN 800 GEV PROTON ACCELERATOR - COMPARISON WITH MONTE-CARLO CALCULATIONS
    COSSAIRT, JD
    BUTALA, SW
    GERARDI, MA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1985, 238 (2-3): : 504 - 508
  • [18] MONTE-CARLO CALCULATION OF ABSORBED DOSE IN XEROMAMMOGRAPHY
    DANCE, DR
    BAKER, AM
    DAVIS, R
    STACEY, AJ
    PHYSICS IN MEDICINE AND BIOLOGY, 1980, 25 (04): : 760 - 760
  • [19] ABSORBED DOSE MEASUREMENTS EXTERNAL TO THICK SHIELDING AT A HIGH-ENERGY PROTON ACCELERATOR - COMPARISON WITH MONTE-CARLO CALCULATIONS
    COSSAIRT, JD
    MOKHOV, NV
    MURPHY, CT
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 197 (2-3): : 465 - 472
  • [20] Fast Monte Carlo dose calculations for brachytherapy
    Rogers, DWO
    Yegin, G
    Taylor, RE
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S17 - S17