A case of α-chain variant hemoglobin (Hb Chad) with falsely high HbA1c levels measured by immunoassay

被引:5
|
作者
Yoshino, Kei [1 ,2 ]
Hirota, Yushi [1 ]
Ogawa, Wataru [1 ]
Sugawara, Kenji [1 ]
Kawaguchi, Akira [3 ]
Yoshino, Hiroshi [4 ]
Ishibashi, Midori [5 ]
Yoshino, Gen [6 ]
Koga, Masafumi [7 ]
机构
[1] Kobe Univ, Dept Internal Med, Div Diabet & Endocrinol, Grad Sch Med,Chuo Ku, 7-5-1 Kusunoki Cho, Kobe, Hyogo 6500017, Japan
[2] Hyogo Prefectural Awaji Med Ctr, Dept Internal Med, Sumoto, Japan
[3] Junshin Awaji Hosp, Dept Internal Med, Awaji, Japan
[4] Fujita Hlth Univ, Dept Geriatr & Cognit Disorders, Sch Med, Toyoake, Aichi, Japan
[5] New Tokyo Hosp, Dept Clin Lab, Matsudo, Chiba, Japan
[6] Shin Suma Gen Hosp, Ctr Diabet, Kobe, Hyogo, Japan
[7] Hakuhoukai Cent Hosp, Dept Internal Med, Amagasaki, Hyogo, Japan
关键词
HbA1c; Hb Chad; Variant hemoglobin; alpha; 2-chain; Glycated albumin;
D O I
10.1007/s13340-021-00529-y
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Variant hemoglobin is often detected during the diagnosis and treatment of diabetes mellitus. We here describe a case of alpha 2-chain variant hemoglobin (Hb Chad) that was identified as a result of differences in HbA1cs values determined by different assays. HbA1c measured by immunoassay was thus falsely high, whereas that measured by high-performance liquid chromatography (HPLC) was slightly low. Sequencing analysis revealed a heterozygous GAG (glutamic acid) -> AAG (lysine) mutation at amino acid position 23 of the alpha 2-globin gene. This residue is located at the surface of the alpha-chain in the crystal structure of hemoglobin. The high HbA1c value determined by immunoassay might have been the result of increased antigenicity of the variant hemoglobin, whereas the low value measured by HPLC reflected differential fractionation of the variant relative to the wild-type protein. Hb Chad has been reported in only three cases to date, and HbA1c was measured for the first time. This is the first case where falsely high HbA1c measured by immunoassay due to increased antigenicity in alpha-chain variant hemoglobin. This case highlights the importance of comparison with other parameters related to plasma glucose such as glycated albumin if an HbA1c abnormality is suspected.
引用
收藏
页码:330 / 335
页数:6
相关论文
共 50 条
  • [31] Interference of Hemoglobin (Hb) Hope on Measurement of HbA1c Using an HPLC Method
    Lorenzo-Medina, Mercedes
    De-La-Iglesia, Silvia
    Ropero, Paloma
    Nogueira-Salgueiro, Patricia
    Gonzalez-Fernandez, F. Ataulfo
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2021, 15 (04): : 974 - 975
  • [32] Cases with Hb Toranomon show abnormal HbA1c levels measured by upgraded high-performance liquid chromatography models
    Ijima H.
    Jinnouchi H.
    Hamaguchi K.
    Ohguni S.
    Haga Y.
    Nagashima M.
    Miyazaki A.
    Koga M.
    Diabetology International, 2011, 2 (4) : 202 - 207
  • [33] Can an Abnormal HbA1c Result Indicate the Presence of a Hemoglobin Variant?
    Kip, Nefize S.
    Mukherjee, Sandeep
    Wheeler, Scott
    Carr, Ann
    Abdulkareem, Wissam
    Schmitt, Jessicia
    Bragg, Carla
    Wesler, Jordan
    Edmondson, Candy
    Toombs, Tiffany
    Dunn, Dianna
    Newman, MaryBeth
    Maynard, Hannah
    Chandra, Pranil
    Middleman, Benton
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2024, 26 (06): : S7 - S8
  • [34] A DIABETIC CASE OF HB RIYADH WITH A LOW HBA1C VALUE
    MAEZAWA, Y
    YAMAUCHI, M
    NAKABAYASHI, T
    TOSHIMA, K
    IKEDA, K
    TODA, G
    INTERNAL MEDICINE, 1993, 32 (02) : 128 - 132
  • [35] Hemoglobin HbA1c and glucose blood levels in diabetic patients
    Tahirovic, I
    Mahovac, E.
    Dizdar, M.
    Toromanovic, J.
    Mahmutovic, O.
    Lepara, Z.
    Ajanovic, A.
    GLASNIK HEMICARA I TEHNOLOGA BOSNE I HERCEGOVINE, 2018, (50): : 13 - 18
  • [36] Sample transport and/or storage can cause falsely low HbA1c levels in blood cells measured by enzymatic assay
    Koga, Masafumi
    Okumiya, Toshika
    Ishibashi, Midori
    DIABETOLOGY INTERNATIONAL, 2020, 11 (02) : 155 - 157
  • [37] Sample transport and/or storage can cause falsely low HbA1c levels in blood cells measured by enzymatic assay
    Masafumi Koga
    Toshika Okumiya
    Midori Ishibashi
    Diabetology International, 2020, 11 : 155 - 157
  • [38] Influence of Hemoglobin Strasbourg, a Rare High Oxygen Affinity Hemoglobin Variant, on Different Methods of HbA1c Measurement
    Wagner, Marcus
    Stoffel-Wagner, Birgit
    Zur, Berndt
    HEMOGLOBIN, 2024, 48 (03) : 209 - 211
  • [39] Effect of Hb H disease on HbA1c measurements as measured by different methods
    唐娟
    ChinaMedicalAbstracts(InternalMedicine), 2018, 35 (02) : 79 - 80
  • [40] Effects of hemoglobin (Hb) E and HbD traits on measurements of glycated Hb (HbA1c) by 23 methods
    Little, Randie R.
    Rohlfing, Curt L.
    Hanson, Steve
    Connolly, Shawn
    Higgins, Trefor
    Weykamp, Cas W.
    D'Costa, Mario
    Luzzi, Veronica
    Owen, William E.
    Roberts, William L.
    CLINICAL CHEMISTRY, 2008, 54 (08) : 1277 - 1282