PVC membrane and coated graphite potentiometric sensors based on dibenzo-21-crown-7 for selective determination of rubidium ions

被引:14
|
作者
Shamsipur, M [1 ]
Alizadeh, K
Hosseini, M
Mousavi, MF
机构
[1] Razi Univ, Dept Chem, Kermanshah, Iran
[2] Taebiat Modarres Univ, Dept Chem, Tehran, Iran
[3] Univ Tehran, Dept Chem, Tehran, Iran
关键词
Rb+-selective electrodes; PVC membrane; dibenzo-21-crown-7; potentiometry;
D O I
10.1081/AL-200050163
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Solution studies on the binding properties of dibenzo-21 -crown-7 (DB21 C7) with alkali metal and ammonium ions revealed the occurrence of a selective 1:1 complexation of the ligand with Rb+ ion. Consequently, DB21C7 was used as a suitable ionophore for the preparation of novel polymeric membrane (PME) and coated graphite (CGE) Rb+-selective electrodes. The electrodes exhibit near-Nernstian behavior for Rb+-ions over concentration ranges of 5.0 x 10(-5) to 1.0 x 10(-1) M for PME and 1.0 X 10(-5) to 5.0 x 10(-2) M for CGE with limits of detection of 1.5 x 10(-5) M for PME and 7.1 X 10(-6)M for CGE. The proposed potentiometric sensors possess response times of < 40 s and can be used for at least 7 weeks without observing any deviation. The electrodes revealed comparatively good selectivities with respect to many alkali, alkaline earth, transition, and heavy metal ions. The working pH range of the electrodes is 3.5-8.0.
引用
收藏
页码:573 / 588
页数:16
相关论文
共 50 条
  • [31] Novel PVC-based coated graphite electrode for selective determination of quinoline yellow
    S. Rouhani
    T. Haji-ghasemi
    Journal of the Iranian Chemical Society, 2009, 6 : 679 - 685
  • [32] Novel PVC-Based Coated Graphite Electrode for Selective Determination of Quinoline Yellow
    Rouhani, S.
    Haji-ghasemi, T.
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2009, 6 (04) : 679 - 685
  • [33] Conductance study of the thermodynamics of dibenzo-21-crown-7 complexes with Na+, K+, Rb+ and Cs+ ions in acetonitrile solution
    Shamsipur, H.
    Zare, K.
    Shamsipur, M.
    POLISH JOURNAL OF CHEMISTRY, 2006, 80 (10) : 1755 - 1762
  • [34] A novel PVC-membrane-coated graphite sensor based on an anthraquinone derivative membrane for the determination of lead
    Riahi, S
    Mousavi, MF
    Shamsipur, M
    Sharghi, H
    ELECTROANALYSIS, 2003, 15 (19) : 1561 - 1565
  • [35] PVC Membrane Potentiometric Sensor Based on a Schiff Base for Determination of Ho3+ ions
    Tamaddon, Atefeh
    Sadeghi, Hayedeh Bagheri
    Mollaei, Somayeh
    Ebrahimi, Arash Afshar
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2014, 6 (06): : 676 - 687
  • [36] PVC-Membrane electrodes based on 18-crown-6 and dibenzo-18-crown-6 ethers for determination of silver
    Zareh, Mohsen Mousa
    Akl, Magda A.
    Gohneim, Ahmd Khlil
    El-Aziz, Mohmed Hussin Abd
    TURKISH JOURNAL OF CHEMISTRY, 2007, 31 (04) : 449 - 456
  • [37] Molecularly imprinted polymer Based PVC-Membrane-Coated graphite electrode for the determination of metoprolol
    M. Saber Tehrani
    M. T. Vardini
    P. Abroomand Azar
    S. W. Husain
    Journal of the Iranian Chemical Society, 2010, 7 (3) : 759 - 769
  • [38] PVC-based Mn(III) porphyrin membrane coated graphite electrode for determination of histidine
    Amini, MK
    Shahrokhian, S
    Tangestaninejad, S
    ANALYTICAL CHEMISTRY, 1999, 71 (13) : 2502 - 2505
  • [39] Molecularly Imprinted Polymer Based PVC-Membrane-Coated Graphite Electrode for the Determination of Metoprolol
    Tehrani, Mohammad Saber
    Vardini, Mohammad Taghi
    Azar, Parviz Abroomand
    Husain, Syed Waqif
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2010, 5 (01): : 88 - 104
  • [40] Molecularly Imprinted Polymer Based PVC-Membrane-Coated Graphite Electrode for the Determination of Metoprolol
    Tehrani, M. Saber
    Vardini, M. T.
    Azar, P. Abroomand
    Husain, S. W.
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2010, 7 (03) : 759 - 769