Investigation of performance of semi-insulating GaAs detectors irradiated by high γ doses

被引:0
|
作者
Necas, V [1 ]
Anh, TL
Sekácová, K
Darmo, J
Dubecky, F
Perd'ochová, A
机构
[1] Slovak Univ Technol Bratislava, Fac Elect Engn & Informat Technol, Dept Nucl Phys & Technol, SK-81219 Bratislava, Slovakia
[2] Slovak Univ Technol Bratislava, Fac Civil Engn, Dept Phys, SK-81219 Bratislava, Slovakia
[3] Slovak Acad Sci, Inst Elect Engn, SK-84239 Bratislava, Slovakia
关键词
GaAs; detector; gamma-ray irradiation; gamma-doses; charge-collection efficiency;
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We report here the preliminary results on liquid encapsulated Czochralski (LEC) semi-insulating (SI) GaAs detectors after gamma irradiation. The detectors have been irradiated with 1.17 and 1.33 MeV photons from Co-60 With doses up to 19.2 kGy. Total doses correspond to the photon flux by the order of 10(13) gamma /mm(2) incident on the device. The detectors before and after exposure to various radiation doses have been characterised. The I-V characteristics for both polarities and pulse-height spectra versus voltage applied at the temperature of 295 K using 122keV Co-57 gamma -source were measured. A significant increase of charge-collection efficiency after irradiation of detectors was observed. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:348 / 351
页数:4
相关论文
共 50 条
  • [1] Performance of radiation detectors based on semi-insulating GaAs and InP
    Dubecky, F
    Huran, J
    Darmo, J
    Zat'ko, B
    Krempasky, M
    Bohácek, P
    Sekácová, M
    Besse, I
    Necas, V
    Hotovy, I
    Fornari, R
    Gombia, E
    Pelfer, PG
    SENSORS AND MICROSYSTEMS, 2000, : 437 - 441
  • [2] Spectroscopic performance of semi-insulating GaAs detectors for digital radiography
    Bertolucci, E
    Conti, M
    Mettivier, G
    Russo, P
    Cola, A
    Quaranta, F
    Vasanelli, L
    Bisogni, MG
    Bottigli, U
    Fantacci, ME
    Stefanini, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 422 (1-3): : 247 - 251
  • [3] Study of the trap influence on the performance of semi-insulating GaAs detectors
    Istituto per lo studio di Nuovi, Materiali per l'Elettronica, Lecce, Italy
    Nucl Instrum Methods Phys Res Sect A, 3 (349-354):
  • [4] A study of the trap influence on the performance of semi-insulating GaAs detectors
    Cola, A
    Quaranta, F
    Vasanelli, L
    Canali, C
    Cavallini, A
    Nava, F
    Fantacci, ME
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 395 (03): : 349 - 354
  • [5] Microscopic modelling of semi-insulating GaAs detectors
    Cola, A
    Vasanelli, L
    Reggiani, L
    Cavallini, A
    Nava, F
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 395 (01): : 98 - 100
  • [6] The investigation of semi-insulating GaAs detectors properties after neutron irradiation
    Ladziansky, M.
    Sagatova, A.
    Necas, V.
    ASDAM 2008, CONFERENCE PROCEEDINGS, 2008, : 179 - 182
  • [7] Role of electrode metallization in performance of semi-insulating GaAs radiation detectors
    Dubecky, Frantisek
    Bohacek, Pavol
    Sekacova, Maria
    Zat'ko, Bohumir
    Lalinsky, Tibor
    Linhart, Vladimir
    Sagatova-Perd'ochova, Andrea
    Mudron, Jan
    Pospisil, Stanislav
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 576 (01): : 87 - 89
  • [8] On the spectrometric performance limit of radiation detectors based on semi-insulating GaAs
    Zatko, B
    Dubecky, F
    Bohácek, P
    Gombia, E
    Frigeri, P
    Mosca, R
    Franchi, S
    Huran, J
    Necas, V
    Sekácová, M
    Förster, A
    Kordos, P
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 531 (1-2): : 111 - 120
  • [9] Influence of contacts and substrate on semi-insulating GaAs detectors
    Irsigler, R
    Geppert, R
    Goppert, R
    Ludwig, J
    Rogalla, M
    Runge, K
    Schmid, T
    Webel, M
    Weber, C
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 395 (01): : 71 - 75
  • [10] Influence of substrate on the performances of semi-insulating GaAs detectors
    Baldini, R
    Vanni, P
    Nava, F
    Canali, C
    Lanzieri, C
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 449 (1-2): : 268 - 276