Influence of a Compatible Design on Physical Human-Robot Interaction Force: a Case Study of a Self-Adapting Lower-Limb Exoskeleton Mechanism

被引:13
|
作者
Li, Jianfeng [1 ]
Zuo, Shiping [1 ]
Xu, Chenghui [1 ]
Zhang, Leiyu [1 ]
Dong, Mingjie [1 ]
Tao, Chunjing [2 ]
Ji, Run [2 ]
机构
[1] Beijing Univ Technol, Coll Mech Engn & Appl Elect Technol, Beijing 100124, Peoples R China
[2] Natl Res Ctr Rehabil Tech Aids, Beijing 100176, Peoples R China
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
Lower-limb exoskeleton mechanism; Compatible design; Axis misalignment; Self-adapting; Physical human-robot interaction force; LEG EXOSKELETON; KNEE-JOINT; GAIT; RECOVERY; MOVEMENT; THERAPY; STROKE; MODEL; ARM;
D O I
10.1007/s10846-019-01063-5
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
In the kinematic design of wearable exoskeletons, the issue of axis misalignments between the human and the exoskeleton joints should be well dealt with. Otherwise, large physical human-robot interaction (p-HRI) forces may occur at the human-robot interfaces, which makes the p-HRI uncomfortable or even unsafe. To cope with this issue, a kinematically compatible design approach of wearable exoskeletons has been investigated by researchers, and great development has been made in recent years. Moreover, the influence of such a design on the exoskeleton's p-HRI performance should be evaluated to determine if the design is feasible. In this paper, a self-adapting lower-limb exoskeleton mechanism for three degrees of freedom gait training is proposed, and the mechanical structure of the exoskeleton mechanism is designed in detail. Then, based on the presented exoskeleton mechanism and the use of suitable force/torque sensors, a p-HRI force measurement system is developed. Subsequently, the p-HRI forces of the human-robot closed chain under the static and motion modes are detected, and the influence of the self-adapting design on the lower-limb exoskeleton mechanism's p-HRI force feature is evaluated. The results indicate that additional human-robot connective joints could reduce the p-HRI force significantly, the compatible design of the exoskeleton mechanism is effective, and is thus applied to human lower-limb gait training.
引用
收藏
页码:525 / 538
页数:14
相关论文
共 23 条
  • [21] On human-robot interaction of a 3-DOF decoupled parallel mechanism based on the design and construction of a novel and low-cost 3-DOF force sensor
    Sharifzadeh, Mohammad
    Masouleh, Mehdi Tale
    Kalhor, Ahmad
    MECCANICA, 2017, 52 (10) : 2471 - 2489
  • [22] Towards real-time whole-body human dynamics estimation through probabilistic sensor fusion algorithms: A physical human-robot interaction case study
    Latella, Claudia
    Lorenzini, Marta
    Lazzaroni, Maria
    Romano, Francesco
    Traversaro, Silvio
    Akhras, M. Ali
    Pucci, Daniele
    Nori, Francesco
    AUTONOMOUS ROBOTS, 2019, 43 (06) : 1591 - 1603
  • [23] Design & characterization of a bio-inspired 3-DOF Tactile/Force sensor and implementation on a 3-DOF decoupled parallel mechanism for human-robot interaction purposes''
    Hamed, Amin
    Masouleh, Mehdi Tale
    Kalhor, Ahmad
    MECHATRONICS, 2020, 66