Evaluation, comparison and combination of molecularly imprinted polymer solid phase extraction and classical solid phase extraction for the preconcentration of endocrine disrupting chemicals from representative whole water samples

被引:2
|
作者
Steinhaeuser, L. B. E. [1 ]
Westphalen, T. [1 ]
Kaminski, K. [1 ]
Piechotta, C. [1 ]
机构
[1] BAM Fed Inst Mat Res & Testing, Zweiggel Adlershof,Richard Willstter Str 11, D-12489 Berlin, Germany
来源
TALANTA OPEN | 2022年 / 6卷
基金
欧盟地平线“2020”;
关键词
17 beta-Estradiol (E2); 17 alpha-Ethinylestradiol (EE2); Water framework directive (WFD); Molecular imprinted polymer (MIP); Solid phase extraction (SPE) disk; Whole water; TANDEM MASS-SPECTROMETRY; STEROID ESTROGENS; RISK-ASSESSMENT; WATCH LIST; 17-BETA-ESTRADIOL; SUBSTANCES; EXPOSURE; HORMONES; FISH; FATE;
D O I
10.1016/j.talo.2022.100163
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Estrogens are endocrine disrupting chemicals and of high concerns due to demonstrated harmful effects on the environment and low effect levels. For monitoring and risk assessment, several estrogens were included in the "watch list" of the EU Water Framework Directive which sets very low environmental quality standard (EQS) levels for Estrone (E1) and 17 beta-Estradiol (E2) of 0.4 ng L-1 and for 17 alpha-Ethinylestradiol (EE2) of 0.035 ng L-1 requiring sensitive detection methods, as well as extensive sample preparation. A sensitive, derivatization-free, isotope dilution calibration HPLC-MS/MS method for a panel of 5 selected estrogens (including the 3 estrogens of the EU WFD watchlist), and a procedure for the reproducible preparation of a representative whole water matrix including mineral water, humic acids and solid particulate matter are presented. These are used in a diligent comparison of classical solid phase extraction (SPE) on hydrophilic-lipophilic balanced (HLB) phase to SPE on an estrogen-specific molecularly imprinted polymer phase (MISPE) for ultra-trace levels of the analytes (1-10 ng L-1). Additionally, a two-step procedure combining HLB SPE disks followed by MISPE is evaluated. The tow-step procedure provides superior enrichment, matrix removal and sample throughput while maintaining comparable recovery rates to simple cartridge SPE. Estimated method quantification limits (MQLs) range from 0.109-0.184 ng L-1 and thus meet EQS-levels for E1 and E2, but not EE2. The representative whole water matrix provides a reproducible comparison of sample preparation methods and lays the foundation for a certified reference material for estrogen analysis. The presented method will serve as the basis for an extended validation study to assess its use for estrogen monitoring in the environment.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Comparison of molecularly imprinted solid-phase extraction (MISPE) with classical solid-phase extraction (SPE) for the detection of benzodiazepines in post-mortem hair samples
    Anderson, Robert A.
    Ariffin, Marinah M.
    Cormack, Peter A. G.
    Miller, Eleanor I.
    FORENSIC SCIENCE INTERNATIONAL, 2008, 174 (01) : 40 - 46
  • [22] Molecularly Imprinted Polymers for Solid Phase Extraction
    Fengxia Qiao
    Hanwen Sun
    Hongyuan Yan
    Kyung Ho Row
    Chromatographia, 2006, 64 : 625 - 634
  • [23] Molecularly imprinted polymers for solid phase extraction
    Qiao, Fengxia
    Sun, Hanwen
    Yan, Hongyuan
    Row, Kyung Ho
    CHROMATOGRAPHIA, 2006, 64 (11-12) : 625 - 634
  • [24] Synthesis and Evaluation of a Molecularly Imprinted Polymer for Solid Phase Extraction of Ethopabate from Chicken Tissue
    Khorrami, Afshin Rajabi
    Edrisi, Mahtab
    SEPARATION SCIENCE AND TECHNOLOGY, 2010, 45 (03) : 404 - 412
  • [25] Solid-phase extraction using a molecularly imprinted polymer for the selective purification and preconcentration of norfloxacin from seawater
    Li, Huiping
    Chen, Jianlei
    Tan, Liju
    Wang, Jiangtao
    ANALYTICAL LETTERS, 2019, 52 (18) : 2896 - 2913
  • [26] Development of a selective molecularly imprinted polymer-based solid-phase extraction for indomethacin from water samples
    Tao Yang
    Ya-Hui Li
    Shuang Wei
    Yuan Li
    Anping Deng
    Analytical and Bioanalytical Chemistry, 2008, 391 : 2905 - 2914
  • [27] Development of a selective molecularly imprinted polymer-based solid-phase extraction for indomethacin from water samples
    Yang, Tao
    Li, Ya-Hui
    Wei, Shuang
    Li, Yuan
    Deng, Anping
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 391 (08) : 2905 - 2914
  • [28] Continuous solid-phase extraction and preconcentration of bisphenol A in aqueous samples using molecularly imprinted columns
    Blanca San Vicente
    Fernando Navarro Villoslada
    María C. Moreno-Bondi
    Analytical and Bioanalytical Chemistry, 2004, 380 : 115 - 122
  • [29] Application of Molecularly Imprinted Solid Phase Extraction in the Assay of Environmental Samples
    Meng Zihui
    Zhang Qiuyue
    Chen Xiaoping
    Zhou Zhiming
    Wu Yukai
    Wen Hongliang
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2006, 24 (06) : 551 - 554
  • [30] A molecularly imprinted polymer for microdisc solid-phase extraction of parabens from human milk samples
    Melo, Lidervan P.
    Queiroz, Maria Eugenia C.
    ANALYTICAL METHODS, 2013, 5 (14) : 3538 - 3545