Evaluation, comparison and combination of molecularly imprinted polymer solid phase extraction and classical solid phase extraction for the preconcentration of endocrine disrupting chemicals from representative whole water samples

被引:2
|
作者
Steinhaeuser, L. B. E. [1 ]
Westphalen, T. [1 ]
Kaminski, K. [1 ]
Piechotta, C. [1 ]
机构
[1] BAM Fed Inst Mat Res & Testing, Zweiggel Adlershof,Richard Willstter Str 11, D-12489 Berlin, Germany
来源
TALANTA OPEN | 2022年 / 6卷
基金
欧盟地平线“2020”;
关键词
17 beta-Estradiol (E2); 17 alpha-Ethinylestradiol (EE2); Water framework directive (WFD); Molecular imprinted polymer (MIP); Solid phase extraction (SPE) disk; Whole water; TANDEM MASS-SPECTROMETRY; STEROID ESTROGENS; RISK-ASSESSMENT; WATCH LIST; 17-BETA-ESTRADIOL; SUBSTANCES; EXPOSURE; HORMONES; FISH; FATE;
D O I
10.1016/j.talo.2022.100163
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Estrogens are endocrine disrupting chemicals and of high concerns due to demonstrated harmful effects on the environment and low effect levels. For monitoring and risk assessment, several estrogens were included in the "watch list" of the EU Water Framework Directive which sets very low environmental quality standard (EQS) levels for Estrone (E1) and 17 beta-Estradiol (E2) of 0.4 ng L-1 and for 17 alpha-Ethinylestradiol (EE2) of 0.035 ng L-1 requiring sensitive detection methods, as well as extensive sample preparation. A sensitive, derivatization-free, isotope dilution calibration HPLC-MS/MS method for a panel of 5 selected estrogens (including the 3 estrogens of the EU WFD watchlist), and a procedure for the reproducible preparation of a representative whole water matrix including mineral water, humic acids and solid particulate matter are presented. These are used in a diligent comparison of classical solid phase extraction (SPE) on hydrophilic-lipophilic balanced (HLB) phase to SPE on an estrogen-specific molecularly imprinted polymer phase (MISPE) for ultra-trace levels of the analytes (1-10 ng L-1). Additionally, a two-step procedure combining HLB SPE disks followed by MISPE is evaluated. The tow-step procedure provides superior enrichment, matrix removal and sample throughput while maintaining comparable recovery rates to simple cartridge SPE. Estimated method quantification limits (MQLs) range from 0.109-0.184 ng L-1 and thus meet EQS-levels for E1 and E2, but not EE2. The representative whole water matrix provides a reproducible comparison of sample preparation methods and lays the foundation for a certified reference material for estrogen analysis. The presented method will serve as the basis for an extended validation study to assess its use for estrogen monitoring in the environment.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Molecularly imprinted conjugated microporous polymer composite as solid phase extraction adsorbent for the extraction of phenolic endocrine disrupting chemicals in beverages
    Xu, Mingxin
    Li, Jie
    Chang, Qingyun
    Zang, Xiaohuan
    Zhang, Shuaihua
    Wang, Chun
    Wang, Zhi
    MICROCHEMICAL JOURNAL, 2023, 191
  • [2] Molecularly imprinted polymer solid phase extraction of fungicides from wine samples
    Bitar, Manal
    Cayot, Philippe
    Bou-Maroun, Elias
    ANALYTICAL METHODS, 2014, 6 (16) : 6467 - 6472
  • [3] Molecularly imprinted polymers for on-line preconcentration by solid phase extraction of pirimicarb in water samples
    Mena, ML
    Martínez-Ruiz, P
    Reviejo, AJ
    Pingarrón, JM
    ANALYTICA CHIMICA ACTA, 2002, 451 (02) : 297 - 304
  • [4] A molecularly imprinted polymer for solid phase extraction of allantoin
    Xianwen Zhong
    Fang Deng
    Yuehua Wang
    Xubiao Luo
    Microchimica Acta, 2013, 180 : 1453 - 1460
  • [5] A molecularly imprinted polymer for solid phase extraction of allantoin
    Zhong, Xianwen
    Deng, Fang
    Wang, Yuehua
    Luo, Xubiao
    MICROCHIMICA ACTA, 2013, 180 (15-16) : 1453 - 1460
  • [6] Preparation and evaluation of molecularly imprinted polymer of olivetol for solid phase extraction
    Jin Yafeng
    Chen Na
    Liu Runqiang
    Chen Jun
    Bai Lianyang
    Zhang Yuping
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2013, 31 (06) : 587 - 595
  • [7] Nanoporous Carbon as the Solid-Phase Extraction Adsorbent for the Extraction of Endocrine Disrupting Chemicals from Juice Samples
    Juntao Wang
    Lin Hao
    Chun Wang
    Qiuhua Wu
    Zhi Wang
    Food Analytical Methods, 2017, 10 : 2710 - 2717
  • [8] Molecularly imprinted polymer solid-phase extraction of synthetic cathinones from urine and whole blood samples
    Murakami, Takaya
    Iwamuro, Yoshiaki
    Ishimaru, Reiko
    Chinaka, Satoshi
    Hasegawa, Hiroshi
    JOURNAL OF SEPARATION SCIENCE, 2018, 41 (24) : 4506 - 4514
  • [9] Nanoporous Carbon as the Solid-Phase Extraction Adsorbent for the Extraction of Endocrine Disrupting Chemicals from Juice Samples
    Wang, Juntao
    Hao, Lin
    Wang, Chun
    Wu, Qiuhua
    Wang, Zhi
    FOOD ANALYTICAL METHODS, 2017, 10 (08) : 2710 - 2717
  • [10] Molecularly Imprinted Polymer for Solid Phase Extraction of Nicotinamide in Pork Liver Samples
    Del Sole, Roberta
    Scardino, Anna
    Lazzoi, Maria Rosaria
    Vasapollo, Giuseppe
    JOURNAL OF APPLIED POLYMER SCIENCE, 2011, 120 (03) : 1634 - 1641