Surface conditions and electrical breakdown characteristics of ozonized water treated copper electrodes of a vacuum gap

被引:0
|
作者
Kobayashi, S [1 ]
Sekikawa, K [1 ]
Asano, K [1 ]
Saito, Y [1 ]
机构
[1] Saitama Univ, Dept Elect & Elect Syst, Urawa, Saitama 3388570, Japan
来源
ISDEIV: XIXTH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM, VOLS 1 AND 2, PROCEEDINGS | 2000年 / 19卷
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Ozonized water treatment has the advantages that organic contaminants can be removed to produce a passivated oxidized film on the surface and the treated surface condition can be kept in air. This technique has been applied to the surface treatment of oxygen-fee copper electrodes. Experimental results revealed that the breakdown field at the Ist application of voltage was not always improved, but a significant conditioning effect was obtained without any in situ precautions. Moreover, additional in sib sputter cleaning on the ozonized water treated surface improved the Ist breakdown field. Surface analysis clarified that after the ozonized water treatment, the electrode surface was covered with an oxidized film (CuO) and this film was removed to expose bulk copper after conditioning by 500 repetitive breakdowns caused by applying impulse voltages. These results can be attributed to the characteristic that the treated surface can be kept in air.
引用
收藏
页码:47 / 50
页数:4
相关论文
共 50 条
  • [21] EFFECT OF ELECTRODE TEMPERATURE ON VACUUM ELECTRICAL BREAKDOWN BETWEEN PLANE-PARALLEL COPPER ELECTRODES
    DAVIES, DK
    BIONDI, MA
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1968, 13 (02): : 200 - +
  • [22] Breakdown characteristics across micrometer-scale surface gap with aluminum electrodes
    1600, Institute of Electrical Engineers of Japan (134):
  • [23] Electrical Breakdown Characteristics in High-Vacuum Conditions for the Design of Superconducting Coils
    Park, Junyoung
    Shin, Woocheol
    Jeong, Minkyung
    Ku, Bonhyuk
    Lee, Hobin
    Park, Jeonghwan
    Hahn, Garam
    Choi, Seyong
    Hahn, Seungyong
    Kang, Hyoungku
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2024, 34 (05) : 1 - 7
  • [24] BREAKDOWN INITIATION IN VACUUM - ELECTRICAL CHARGE OF MICROPARTICLES EMITTED IN A VACUUM GAP
    TEXIER, C
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1977, 10 (12) : 1693 - 1702
  • [25] Vacuum Breakdown Characteristics of Oxygen-Free Copper Electrodes with Different Keeping Methods and Terms
    Minaminosono, Kota
    Yamano, Yasushi
    Kobayashi, Shinichi
    Saito, Yoshio
    ISDEIV 2008: PROCEEDINGS OF THE XXIIIRD INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM, VOLS 1 AND 2, 2008, : 227 - +
  • [26] Breakdown Characteristics of Spark Discharge on Water Surface (SDWS) with an Air Gap
    Midi, N. S.
    Muhamad, M. K. A.
    Ohyama, R.
    2012 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2012, : 153 - 156
  • [27] ELECTRICAL BREAKDOWN BETWEEN STAINLESS-STEEL ELECTRODES IN VACUUM
    VANOOSTROM, A
    AUGUSTUS, L
    VACUUM, 1982, 32 (03) : 127 - 135
  • [28] MECHANISM OF DC ELECTRICAL BREAKDOWN BETWEEN EXTENDED ELECTRODES IN VACUUM
    DAVIES, DK
    BIONDI, MA
    JOURNAL OF APPLIED PHYSICS, 1971, 42 (08) : 3089 - +
  • [29] PULSED ELECTRICAL BREAKDOWN FROM SUPERCONDUCTING ELECTRODES IN VACUUM DIODES
    SHKURATOV, SI
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 1995, 2 (02) : 251 - 262
  • [30] THE INFLUENCE OF THE ELECTRODE TEMPERATURE ON THE ELECTRICAL BREAKDOWN STRENGTH OF A VACUUM GAP
    SLIVKOV, IN
    SOVIET PHYSICS-TECHNICAL PHYSICS, 1958, 3 (04): : 708 - 709