A Single Intramedullary K-Wire Is Sufficient for the Management of Nonthumb Metacarpal Shaft Fractures

被引:2
|
作者
Abulsoud, Mohamed I. [1 ]
Elmarghany, Mohammed [1 ]
Abdelghany, Tharwat [1 ]
Abdelaal, Mohamed [1 ]
Elhalawany, Mohamed F. [1 ]
Zakaria, Ahmed R. [2 ]
机构
[1] Al Azhar Univ, Dept Orthoped Surg, Fac Med, Cairo, Egypt
[2] Helwan Univ, Dept Orthoped Surg, Helwan, Egypt
关键词
FIXATION; COMPLICATIONS; ANGULATION; HAND;
D O I
10.1155/2021/9963186
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective. This study aims to evaluate the outcome after the internal fixation of diaphyseal metacarpal fractures by a single intramedullary K-wire. Methods. In this prospective case series study, conducted from July 2017 to June 2019 in 23 adult patients with a single, unstable, diaphyseal metacarpal fracture, outcomes after internal surgical fixation using a single antegrade intramedullary K-wire were evaluated. The outcomes were evaluated by union rate, time to union, handgrip measurements at 6 and 12 months, and the modified Disabilities of the Arm, Shoulder, and Hand (DASH) score at 12 months. Results. The study population consisted of 17 males and 6 females, with a mean patient age of 28.4 +/- 8.5 years (range, 16-45 years). The median time to final follow-up was 14 +/- 1.8 months (range: 12-24 months). The mean duration of the union was 7.3 +/- 1.6 weeks (range: 5-11 weeks), with a union rate of 95.7% (22 cases). The mean handgrip strength was 68% +/- 12.8% of the strength of the uninjured hand after 6 months and 92.7% +/- 6.9% after 12 months. The mean modified DASH score was 2.6 +/- 0.26 after 12 months (range: 0-5.8). There were no cases of malrotation or infection. In conclusion, using a single 1.8-2.0 mm K-wire gives excellent functional outcomes and union rate without significant complications when used to treat an unstable metacarpal shaft fracture.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Iatrogenic metacarpal fracture complication secondary to K-wire fixation
    Loh, Charles Yuen Yung
    Ng, Nigel Yong Boon
    Loh, Meiling
    Kandamany, Nanda
    Athanassopoulos, Thanassi
    INDIAN JOURNAL OF PLASTIC SURGERY, 2014, 47 (02) : 271 - 272
  • [42] Diaphyseal forearm fractures in children treated with intramedullary fixation: outcome of K-wire versus elastic stable intramedullary nail
    Calder, PR
    Achan, P
    Barry, M
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2003, 34 (04): : 278 - 282
  • [43] Orthograde intramedullary Kirschner wire fixation of distal metacarpal fractures
    Manner, M
    Roesler, B
    CHIRURG, 2000, 71 (03): : 326 - 330
  • [44] Percutaneous K-Wire Fixation for Femur Shaft Fractures in Children: A Treatment Concepts for Developing Countries
    Sahu, R. L.
    ANNALS OF MEDICAL AND HEALTH SCIENCES RESEARCH, 2013, 3 (02) : 197 - 201
  • [45] Intramedullary Crossed K-wire Fixation for the Hand Fractures is a Useful Treatment Modality: A Prospective Observational Study
    Ahmad, Sabeel
    Gupta, Tushar
    Ansari, Sajid
    Jain, Aakriti
    Barik, Sitanshu
    Singh, Vivek
    STRATEGIES IN TRAUMA AND LIMB RECONSTRUCTION, 2022, 17 (02) : 74 - 80
  • [46] Relative Strengths of Intramedullary K-Wire Techniques for Digital Deformities
    Ehredt, Duane J.
    Kawalec, Jill S.
    Zulauf, Emily E.
    Wetzel, Britain
    Kim, Heong-min
    JOURNAL OF FOOT & ANKLE SURGERY, 2021, 60 (05): : 990 - 993
  • [47] Prospective Multicenter Trial of Modified Retrograde Percutaneous Intramedullary Kirschner Wire Fixation for Displaced Metacarpal Neck and Shaft Fractures
    Rhee, Seung Hwan
    Lee, Sang Ki
    Lee, Sang Lim
    Kim, Jihyeung
    Baek, Goo Hyun
    Lee, Young Ho
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2012, 129 (03) : 694 - 703
  • [48] Modified retrograde percutaneous intramedullary multiple Kirschner wire fixation for treatment of unstable displaced metacarpal neck and shaft fractures
    Lee S.K.
    Kim K.J.
    Choy W.S.
    European Journal of Orthopaedic Surgery & Traumatology, 2013, 23 (5) : 535 - 543
  • [49] METACARPAL FRACTURES TREATMENT: COMPARASION BETWEEN KIRSCHNER WIRE AND INTRAMEDULLARY SCREW
    de Jesus, Bruno Cesar Silva
    da Silva, Clovis Rodrigo Guimaraes Braz Pereira
    Cardoso, Rodrigo Domiciano
    Mauad, Vitor Augusto Queiroz
    Alves, Rafael Saleme
    Pinto, Fernando Nogueira Zambone
    ACTA ORTOPEDICA BRASILEIRA, 2023, 31
  • [50] Supplementary Technique for Unstable Clavicle Shaft Fractures: Interfragmentary Wiring and Temporary Axial K-Wire Pinning
    Dan, Jinmyoung
    Kim, Byung-Kook
    Lee, Ho-Jae
    Kim, Tae-Ho
    Kim, Young-Gun
    CLINICS IN ORTHOPEDIC SURGERY, 2018, 10 (02) : 142 - 148