Left Atrial Appendage Occlusion in Non-Valvular Atrial Fibrillation in a Korean Multi-Center Registry

被引:29
|
作者
Kim, Jung-Sun [1 ]
Lee, Hancheol [1 ]
Suh, Yongsung [1 ]
Pak, Hui-Nam [1 ]
Hong, Geu-Ru [1 ]
Shim, Chi Young [1 ]
Yu, Cheol-Woong [2 ]
Lee, Hyun-Jong [3 ]
Kang, Woong-Chol [4 ]
Shin, Eun-Seok [5 ]
Choi, Rak-Kyeong [3 ]
Kar, Saibal [6 ]
Park, Jai-Wun [7 ,8 ]
Lim, Do-Sun [2 ]
Jang, Yangsoo [1 ]
机构
[1] Yonsei Univ, Coll Med, Severance Cardiovasc Hosp, Seoul 120752, South Korea
[2] Korea Univ, Anam Hosp, Seoul, South Korea
[3] Sejong Gen Hosp, Seoul, South Korea
[4] Gachon Univ, Gil Hosp, Inchon, South Korea
[5] Univ Ulsan, Coll Med, Ulsan Univ Hosp, Ulsan 680749, South Korea
[6] Cedars Sinai Med Ctr, Los Angeles, CA 90048 USA
[7] Coburg Hosp, Dept Cardiol Angiol & Pneumol, Coburg, Germany
[8] Charite, Campus Benjamin Franklin, Dept Cardiol, D-13353 Berlin, Germany
关键词
Atrial fibrillation; Left atrial appendage occlusion; Stroke; WATCHMAN DEVICE; CLOSURE; STROKE; ANTICOAGULATION; RISK; WARFARIN; THERAPY; SINGLE; PREVENTION;
D O I
10.1253/circj.CJ-15-1134
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The aim of this study was to evaluate clinical outcome after left atrial appendage (LAA) occlusion in real clinical practice and compare between Amplatzer cardiac plug (ACP) and Watchman. Methods and Results: From October 2010 to February 2015, 96 successful LAA occlusion procedures were performed using either ACP (n=50) or Watchman device (n=46) in non-valvular atrial fibrillation (AF) patients (59 male; age, 65.1 +/- 9.4 years; CHADS2, 2.5 +/- 1.2; CHA(2)DS(2)-VASC, 3.9 +/- 1.6; HAS-BLED, 2.7 +/- 1.3). The procedure success rate was 96.8%. There were serious complications in 4 patients (4.1%; 2 cardiac tamponade, 1 device embolization, and 1 major bleed). The anticoagulation cessation rate after 6 weeks was 92.7%. During mean 21.9-month follow-up, the incidence of death, stroke, systemic embolization and major bleeding was 5.2%, 4.2%, 0% and 1.0%, respectively. On transesophageal echocardiography of 93 patients within 6 months after the procedure, 24 residual leaks were observed (25.8%; 2 mild, 18 moderate, and 4 major). Clinical outcome was similar for the 2 devices, but peridevice leakage was more frequent with the Watchman than the ACP. Conclusions: LAA occlusion was feasible in non-valvular AF patients with high risk of stroke and hemorrhage. The ACP and Watchman devices were similar in terms of procedural and clinical outcomes.
引用
收藏
页码:1123 / 1130
页数:8
相关论文
共 50 条
  • [41] Demonstration of proof-of-concept of StrokeShield system for complete closure and occlusion of the left atrial appendage for non-valvular atrial fibrillation therapy
    Slaughter, Mark S.
    Monreal, Gretel
    Koenig, Steven C.
    Giridharan, Guruprasad A.
    Tompkins, Landon H.
    Jimenez, Jorge H.
    [J]. PLOS ONE, 2021, 16 (06):
  • [42] Role of Transesophageal Echocardiography during Left Atrial Appendage Occlusion Device Closure in a Patient with Non-Valvular Atrial Fibrillation and Angiodysplasia of the Colon
    Kumar, Dinesh
    Kumar, Sunil
    Desai, Nagraj
    [J]. ANNALS OF CARDIAC ANAESTHESIA, 2018, 21 (01) : 88 - 91
  • [43] Mid-term outcomes of concomitant left atrial appendage closure and catheter ablation for non-valvular atrial fibrillation: a multicenter registry
    Liu, Fang-zhou
    Lin, Wei-dong
    Liao, Hong-tao
    Peng, Jian
    Xue, Yu-mei
    Zhan, Xian-zhang
    Zhu, Jie-ming
    Yiu, Kai-hang
    Li, Yi-fu
    Tse, Hung-fat
    Shi, Li
    Fang, Xian-hong
    Wu, Shu-lin
    [J]. HEART AND VESSELS, 2019, 34 (05) : 860 - 867
  • [44] Stroke prevention in non-valvular atrial fibrillation: Long-Term results of the WATCHMAN left atrial appendage occlusion pilot study
    Sick, P. B.
    Yakubov, S. J.
    Turi, Z. G.
    Mishkel, G.
    Almany, S.
    Grube, E.
    Hauptmann, K.
    Schuler, G.
    Holmes, D. R.
    [J]. EUROPEAN HEART JOURNAL, 2009, 30 : 599 - 599
  • [45] Stroke Prevention in Non-valvular Atrial Fibrillation: Long-Term Results of the WATCHMAN Left Atrial Appendage Occlusion Pilot Study
    Sick, Peter B.
    Turi, Zoltan G.
    Grube, Eberhard
    Schuler, Gerhard
    Hauptmann, Karl E.
    Mishkel, Gregory
    Yakubov, Steven
    Almany, Steven
    Holmes, David R.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (10) : A17 - A17
  • [46] Mid-term outcomes of concomitant left atrial appendage closure and catheter ablation for non-valvular atrial fibrillation: a multicenter registry
    Fang-zhou Liu
    Wei-dong Lin
    Hong-tao Liao
    Jian Peng
    Yu-mei Xue
    Xian-zhang Zhan
    Jie-ming Zhu
    Kai-hang Yiu
    Yi-fu Li
    Hung-fat Tse
    Li Shi
    Xian-hong Fang
    Shu-lin Wu
    [J]. Heart and Vessels, 2019, 34 : 860 - 867
  • [47] Predictive value of left atrial appendage lobes on left atrial thrombus or spontaneous echo contrast in patients with non-valvular atrial fibrillation
    Fan Wang
    Mengyun Zhu
    Xiaoyu Wang
    Wei Zhang
    Yang Su
    Yuyan Lu
    Xin Pan
    Di Gao
    Xianling Zhang
    Wei Chen
    Yawei Xu
    Yuxi Sun
    Dachun Xu
    [J]. BMC Cardiovascular Disorders, 18
  • [48] ABO blood groups: A risk factor for left atrial and left atrial appendage thrombogenic milieu in patients with non-valvular atrial fibrillation
    Fu, Yuan
    Li, Kuibao
    Yang, Xinchun
    [J]. THROMBOSIS RESEARCH, 2017, 156 : 45 - 50
  • [49] Predictive value of left atrial appendage lobes on left atrial thrombus or spontaneous echo contrast in patients with non-valvular atrial fibrillation
    Wang, Fan
    Zhu, Mengyun
    Wang, Xiaoyu
    Zhang, Wei
    Su, Yang
    Lu, Yuyan
    Pan, Xin
    Gao, Di
    Zhang, Xianling
    Chen, Wei
    Xu, Yawei
    Sun, Yuxi
    Xu, Dachun
    [J]. BMC CARDIOVASCULAR DISORDERS, 2018, 18
  • [50] Total Bilirubin Level is Associated with the Risk of Left Atrial Appendage Thrombosis in Patients with Non-Valvular Atrial Fibrillation
    Meng, Weihao
    Wang, Leigang
    Fan, Hongxuan
    Mao, Shaobin
    Song, Xiaosu
    Zhang, Zhijun
    Wang, Haixiong
    Liang, Bin
    [J]. GLOBAL HEART, 2022, 17 (01)