Sensitive voltammetric determination of bromate by using ion-exchange property of a Sn(II)-clinoptilolite-modified carbon paste electrode

被引:56
|
作者
Tamiji, Tahmineh [1 ,2 ]
Nezamzadeh-Ejhieh, Alireza [1 ]
机构
[1] Islamic Azad Univ, Shahreza Branch, Dept Chem, Shahreza 31186145, Isfahan, Iran
[2] Islamic Azad Univ, Shahreza Branch, Young Researchers & Elite Club, Shahreza, Isfahan, Iran
关键词
Response surface area (RSM); Zeolite-modified electrodes; Clinoptilolite; Nanoparticles; Bromate; ZEOLITE-MODIFIED ELECTRODES; SELECTIVE DETERMINATION; IMPEDANCE SPECTROSCOPY; URIC-ACID; OXIDATION; REDUCTION; SURFACE; OXIDE; CHROMATOGRAPHY; OPTIMIZATION;
D O I
10.1007/s10008-018-4119-4
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A modified carbon paste electrode with Sn(II)-exchanged clinoptilolite nanoparticles (CNP-Sn(II)-CPE) showed voltammetric current (in cyclic voltammetry (CV)) for Sn(II)/Sn(IV) in sulfuric acid electrolyte (pH 2). The peak current was decreased when bromate was added to the solution. Hence, this decrease was used for indirect voltammetric determination of bromate. In designed experiments using response surface methodology (RSM) approach in square-wave voltammetry (SqW), strong acidic pH values (pH 1.8-2.5) caused an increased SqW voltammetric response, because such pH values bring sufficient Sn(II) as the electroactive species at the electrode surface via ion-exchange process. The optimal variables obtained are sulfuric acid as supporting electrolyte at pH 1.80, modifier% at 25, amplitude at 498.4mV, step potential at 5.4mV, and frequency at 25Hz. The peak current of Sn(II)/Sn(IV) redox pair was inversely proportionate to the concentration of bromate. Hence, I (difference in peak current in the absence and presence of bromate) was proportionally increased with increasing the concentration of bromate in the range of 5.00 to 100.00molL(-1) with a detection limit of 0.06molL(-1) bromate. The effect of some strong oxidizing agents was studied, and the results showed that when such agents are present at levels of 2.5 to 5 times greater than the bromate in the solution, they can cause a maximum error of 3% in the determination of bromate in sulfuric acid electrolyte at pH 2.5.
引用
收藏
页码:143 / 157
页数:15
相关论文
共 50 条
  • [21] Voltammetric copper(II) determination with a montmorillonite-modified carbon paste electrode
    Kula, P
    Navratilova, Z
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1996, 354 (5-6): : 692 - 695
  • [22] Voltammetric copper(II) determination with a montmorillonite-modified carbon paste electrode
    Institute of Geonics, Academy of, Sciences of Czech Republic,, Studertska 1768, 708 00 Ostrava, Czech Republic
    Fresenius J Anal Chem, 5-6 (692-695):
  • [23] VOLTAMMETRIC DETERMINATION OF TRACES OF COBALT(II) WITH A CHEMICALLY MODIFIED CARBON PASTE ELECTRODE
    GAO, ZQ
    LI, PB
    ZHAO, ZF
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1991, 339 (03): : 137 - 141
  • [24] A zeolite modified carbon paste electrode based on copper exchanged clinoptilolite nanoparticles for voltammetric determination of metronidazole
    Shahnazari-Shahrezaie, Elahe
    Nezamzadeh-Ejhieh, Alireza
    RSC ADVANCES, 2017, 7 (23): : 14247 - 14253
  • [25] Fast and sensitive determination of captopril by voltammetric method using ferrocenedicarboxylic acid modified carbon paste electrode
    Karimi-Maleh, H.
    Ensafi, A. A.
    Allafchian, A. R.
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2010, 14 (01) : 9 - 15
  • [26] Fast and sensitive determination of captopril by voltammetric method using ferrocenedicarboxylic acid modified carbon paste electrode
    H. Karimi-Maleh
    A. A. Ensafi
    A. R. Allafchian
    Journal of Solid State Electrochemistry, 2010, 14 : 9 - 15
  • [27] A sensitive and simple modified zeolitic carbon paste electrode for indirect voltammetric determination of nitrate
    Nosuhi, Motahare
    Nezamzadeh-Ejhieh, Alireza
    IONICS, 2018, 24 (07) : 2135 - 2145
  • [28] A sensitive and simple modified zeolitic carbon paste electrode for indirect voltammetric determination of nitrate
    Motahare Nosuhi
    Alireza Nezamzadeh-Ejhieh
    Ionics, 2018, 24 : 2135 - 2145
  • [29] Sensitive Voltammetric Determination of Cadmium(II) with 8-Hydroxyquinoline and Ionic Liquid Modified Carbon Paste Electrode
    Jia, Shaohui
    Gong, Shixing
    Cheng, Yong
    Wang, Huiyun
    Liu, Hejian
    Zhang, Bo
    Sun, Wei
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2014, 61 (11) : 1217 - 1222
  • [30] VOLTAMMETRIC DETERMINATION OF IODIDE WITH A CARBON PASTE ELECTRODE MODIFIED WITH ANION-EXCHANGE RESINS
    KALCHER, K
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1985, 321 (07): : 666 - 670