Value of repeat endoscopic ultrasound-guided fine needle aspiration for suspected pancreatic cancer

被引:79
|
作者
Eloubeidi, Mohamad A. [1 ,2 ]
Varadarajulu, Shyam [1 ,2 ]
Desai, Shilpa [1 ,2 ]
Wilcox, C. Mel [1 ,2 ]
机构
[1] Univ Alabama Birmingham, Dept Med, Div Gastroenterol & Hepatol, Birmingham, AL 35294 USA
[2] Univ Alabama Birmingham, Pancreaticobiliary Ctr, Birmingham, AL 35294 USA
关键词
endoscopic ultrasound; fine needle aspiration; pancreatic cancer; pitfalls;
D O I
10.1111/j.1440-1746.2007.05119.x
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and Aims: Endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) is a safe and accurate technique for diagnosing pancreatic cancer. The value of repeat EUS-FNA in patients with high clinical suspicion for pancreatic cancer after an inconclusive index study is unknown. Our aims were to determine the yield and success of repeat EUS-FNA and the reasons for failure of initial EUS-FNA. Methods: This was a retrospective analysis of prospectively collected data in a tertiary University based referral center for pancreatico-biliary disorders. All patients who underwent more then one EUS-FNA for evaluation of suspected pancreatic cancer over a five and a half year period were included in this analysis. Results: Of the 547 procedures performed on 517 patients, 24 (4.6%) patients underwent 51 repeat EUS-FNA procedures. Initial EUS-FNA was atypical/suspicious in 10 (41.6%), benign in 10 (41.6%), malignant in two (8.3%), and failed/indeterminate in two (8.3%) patients. Eight of 10 (80%) patients with atypical/suspicious findings at initial EUS-FNA were diagnosed with malignancy on repeat EUS-FNA. Of the 10 patients with benign findings at initial EUS-FNA, repeat study diagnosed two (20%) with malignancy and the rest were confirmed benign on long-term follow up (average 530 days, SD 369 days). Of the two patients with indeterminate findings at initial EUS-FNA, repeat study diagnosed one patient with malignant disease and the other with benign disease that was confirmed by long-term follow up. Of the two patients diagnosed with neoplastic disease at initial EUS-FNA, repeat EUS-FNA with immunostains downgraded both to chronic pancreatitis. Repeat EUS-FNA facilitated determination of the true status of disease in 20 of 24 patients (accuracy 84%). Suspected reasons for failed initial EUS-FNA were: coexisting pancreatitis (n = 10; 42%), technical difficulty due to scope positioning in uncinate lesion/sedation failure (n = 4; 16.7%), difficult cytology (partly cystic, extensive necrosis, well-differentiated adenocarcinoma) (n = 4; 16.7%), presence of ascites or collaterals (n = 3; 12.5%), pathologist's interobserver variation (n = 2; 8.33%), and unknown reason in one patient. Conclusion: Repeat EUS-FNA is warranted in patients with high clinical suspicion for pancreatic cancer despite indeterminate or negative findings at initial EUS-FNA.
引用
收藏
页码:567 / 570
页数:4
相关论文
共 50 条
  • [41] Pancreatic tuberculous abscess diagnosed by endoscopic ultrasound-guided fine needle aspiration
    Asim, Shabbir
    Manjari, Lahiri
    Kenneth, Mak Seck-wai
    Alexander, Chang Russell
    Christopher, Khor
    Ho, Khek-Yu
    [J]. JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2010, 60 (06) : 499 - 501
  • [42] Utilizing Endoscopic Ultrasound-Guided Fine Needle Aspiration in Identifying Molecular Targets for Pancreatic Cancer
    Ogbonna, Onyekachi Henry
    Saif, Muhammad Wasif
    [J]. JOURNAL OF THE PANCREAS, 2013, 14 (04): : 316 - 317
  • [43] Diagnosis of pancreatic tumors by endoscopic ultrasound-guided fine-needle aspiration
    José Celso Ardengh
    César Vivian Lopes
    Luiz Felipe Pereira de Lima
    Juliano Rodrigues de Oliveira
    Filadélfi o Venco
    Giulio Cesare Santo
    José Luiz Pimenta Módena
    [J]. World Journal of Gastroenterology, 2007, (22) : 3112 - 3116
  • [44] Endoscopic ultrasound-guided fine needle aspiration in the evaluation of pancreatic neuroendocrine neoplasms
    Raddaoui, Emad M.
    [J]. SAUDI MEDICAL JOURNAL, 2010, 31 (11) : 1271 - 1273
  • [45] The Role of Endoscopic Ultrasound-Guided Fine-Needle Aspiration of Pancreatic Lesions
    Yoshinaga, Shigetaka
    [J]. NORTH AMERICAN JOURNAL OF MEDICAL SCIENCES, 2016, 8 (01) : 12 - 12
  • [46] Endoscopic Ultrasound-Guided Fine-Needle Aspiration of an Unusual Pancreatic Mass
    Antonini, Filippo
    Santinelli, Alfredo
    Macarri, Giampiero
    [J]. CLINICAL GASTROENTEROLOGY AND HEPATOLOGY, 2015, 13 (03) : E25 - E25
  • [47] Endoscopic ultrasound-guided fine-needle aspiration for the diagnosis of pancreatic lesions
    Ryozawa, S
    [J]. GASTROINTESTINAL ENDOSCOPY, 2002, 56 (04) : S123 - S123
  • [48] Endoscopic ultrasound-guided fine needle aspiration of the liver
    Cameron, S. E. H.
    Evans, R. A.
    Debol, S. M.
    Mallery, S.
    Stelow, E. B.
    [J]. MODERN PATHOLOGY, 2007, 20 : 65A - 65A
  • [49] ENDOSCOPIC ULTRASOUND-GUIDED FINE-NEEDLE ASPIRATION
    CHANG, KJ
    KATZ, KD
    DURBIN, TE
    ERICKSON, RA
    BUTLER, JA
    LIN, F
    WUERKER, RB
    [J]. GASTROINTESTINAL ENDOSCOPY, 1994, 40 (06) : 694 - 699
  • [50] Endoscopic ultrasound-guided fine-needle aspiration diagnosis of pancreatic schwannoma
    Barresi, Luca
    Tarantino, Ilaria
    Granata, Antonino
    Traina, Mario
    [J]. DIGESTIVE AND LIVER DISEASE, 2013, 45 (06) : 523 - 523