Frequency doubling technology and scanning laser tomography in eyes with generalized enlargement of optic disc cupping

被引:5
|
作者
Kunimatsu, S
Tomita, G
Araie, M
Aihara, M
Suzuki, Y
Wase, A
Koseki, N
Matsumoto, S
Yamazaki, Y
Yoshikawa, K
机构
[1] Univ Tokyo, Grad Sch Med, Dept Ophthalmol, Bunkyo Ku, Tokyo 1138655, Japan
[2] Teikyo Univ Med, Dept Ophthalmol, Ichihara Hosp, Ichihara, Japan
[3] Tajimi Municipal Hosp, Dept Ophthalmol, Gifu, Japan
[4] Koseki Eye Clin, Saitama, Japan
[5] Tokyo Post & Telecommun, Dept Ophthalmol, Tokyo, Japan
[6] Nihon Univ, Sch Med, Dept Ophthalmol, Tokyo, Japan
[7] Yoshikawa Eye Clin, Tokyo, Japan
关键词
cup shape measure; frequency doubling technology; the Heidelberg Retina Tomograph; large C/D eyes; large cup/disc ratio; normal-tension glaucoma; scanning laser tomography; standard achromatic automated perimetry;
D O I
10.1097/01.ijg.0000169392.02180.5b
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To characterize functional and structural changes in eyes with generalized enlargement of optic disc cupping (vertical cup/disc ratio >= 0.8), normal intraocular pressure, normal standard achromatic automated perimetry (SAP) results, and no other ophthalmoscopic findings suggesting glaucoma (large C/D eyes) using frequency doubling technology (FDT) and the Heidelberg Retina Tomograph (HRT). Methods: This comparative observational case series included 30 large C/D eyes (30 subjects), 17 eyes (17 patients) with early-stage normal tension glaucoma with generalized enlargement of optic disc cupping (NTG eyes), and 25 eyes from 25 normal subjects (normal eyes). Results with Humphrey 30-2, FDT N-30 threshold programs, and HRT were compared among these groups. Large C/D eyes were subdivided into FDT-normal and -abnormal eyes according to the predetermined criteria and HRT parameters were compared among them. Results: No significant difference was seen in HRT parameters between the large C/D and NTG eyes. In the large C/D eyes, FDT mean deviation was lower than in the normal eyes and higher than in the NTG eyes, whereas FDT pattern standard deviation was smaller than in the NTG eyes (P = 0.02-0.03). Among HRT parameters, only cup shape measure (CSM) showed significant negative correlation with FDT mean deviation in the large C/D eyes. Between FDT-normal and -abnormal subgroups, only CSM showed significant difference (P < 0.01). Conclusion: Frequency doubling technology showed abnormalities in large C/D eyes. Only CSM showed significant correlation with FDT result and difference between those with normal and abnormal FDT results. In management of large C/D eyes, FDT and CSM will be useful to detect functional and structural change.
引用
收藏
页码:280 / 287
页数:8
相关论文
共 50 条
  • [1] Use of a confocal laser scanning ophthalmoscope to detect glaucomatous cupping of the optic disc
    Cucevic, V
    Brooks, AMV
    Strang, NT
    Klein, AG
    Nugent, KA
    [J]. AUSTRALIAN AND NEW ZEALAND JOURNAL OF OPHTHALMOLOGY, 1997, 25 (03): : 217 - 220
  • [2] Reversal of optic disc cupping after glaucoma surgery analyzed with a scanning laser tomograph
    Lesk, MR
    Spaeth, GL
    Azuara-Blanco, A
    Araujo, SV
    Katz, LJ
    Terebuh, AK
    Wilson, RP
    Moster, MR
    Schmidt, CM
    [J]. OPHTHALMOLOGY, 1999, 106 (05) : 1013 - 1018
  • [3] Optic disc cupping after optic neuritis evaluated with optic coherence tomography
    Rebolleda, G.
    Noval, S.
    Contreras, I.
    Arnalich-Montiel, F.
    Garcia-Perez, J. L.
    Munoz-Negrete, F. J.
    [J]. EYE, 2009, 23 (04) : 890 - 894
  • [4] Optic disc cupping after optic neuritis evaluated with optic coherence tomography
    G Rebolleda
    S Noval
    I Contreras
    F Arnalich-Montiel
    J L García-Perez
    F J Muñoz-Negrete
    [J]. Eye, 2009, 23 : 890 - 894
  • [5] Scanning laser tomography to evaluate optic discs of normal eyes
    Nakamura, H
    Maeda, T
    Suzuki, Y
    Inoue, Y
    [J]. JAPANESE JOURNAL OF OPHTHALMOLOGY, 1999, 43 (05) : 410 - 414
  • [6] Frequency doubling technology and confocal scanning ophthalmoscopic optic disc analysis in open-angle glaucoma with hemifield defects
    Wu, LL
    Suzuki, Y
    Kunimatsu, S
    Araie, M
    Iwase, A
    Tomita, G
    [J]. JOURNAL OF GLAUCOMA, 2001, 10 (04) : 256 - 260
  • [7] Detection of glaucomatous optic disc hemorrhages by confocal scanning laser tomography
    Dichtl, A
    Jonas, JB
    Mardin, CY
    [J]. ARCHIVES OF OPHTHALMOLOGY, 1997, 115 (06) : 800 - 801
  • [8] Preperimetric glaucoma diagnosis by confocal scanning laser tomography of the optic disc
    Mardin, CY
    Horn, FK
    Jonas, JB
    Budde, WM
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 1999, 83 (03) : 299 - 304
  • [9] Optic Disc Progression in Glaucoma: Comparison of Confocal Scanning Laser Tomography to Optic Disc Photographs in a Prospective Study
    Chauhan, Balwantray C.
    Hutchison, Donna M.
    Artes, Paul H.
    Caprioli, Joseph
    Jonas, Jost B.
    LeBlanc, Raymond P.
    Nicolela, Marcelo T.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2009, 50 (04) : 1682 - 1691
  • [10] Clinical variables associated with glaucomatous injury in eyes with large optic disc cupping
    Greenfield, DS
    Bagga, H
    [J]. OPHTHALMIC SURGERY LASERS & IMAGING, 2005, 36 (05) : 401 - 409