Theoretical calculations of isoelectronic line-ratio for plasma electron temperature diagnosis

被引:5
|
作者
Wu, ZQ [1 ]
Han, GX [1 ]
Yan, J [1 ]
Pang, JQ [1 ]
机构
[1] Inst Appl Phys & Computat Math, Beijing 100088, Peoples R China
关键词
D O I
10.1088/0256-307X/20/4/326
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
A model is developed to calculate the emission spectrum of non-local thermodynamic equilibrium (LTE) plasmas. The collisional-radiative model is adopted for non-LTE population calculations. Configuration-averaged rate coefficients that are needed in the rate equations are obtained based on the first-order perturbation theory. The Hartree-Fock-Slater self-consistent-field method is used to calculate electron wavefunctions. The present model is applied to the calculation of isoelectronic line-ratio of Cr and Ti, which is useful for plasma electron temperature diagnosis.
引用
收藏
页码:529 / 532
页数:4
相关论文
共 50 条
  • [41] Time-Resolved Electron Temperature in an Argon Theta Pinch by Line Ratio Methods
    Meeks, Warner C.
    Rovey, Joshua L.
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2016, 44 (08) : 1411 - 1418
  • [42] High-resolution electron temperature measurements using the plasma line asymmetry
    Nicolls, M. J.
    Sulzer, M. P.
    Aponte, N.
    Seal, R.
    Nikoukar, R.
    Gonzalez, S. A.
    GEOPHYSICAL RESEARCH LETTERS, 2006, 33 (18)
  • [43] Origin of low proton-to-electron temperature ratio in the Earth's plasma sheet
    Grigorenko, E. E.
    Kronberg, E. A.
    Daly, P. W.
    Ganushkina, N. Yu.
    Lavraud, B.
    Sauvaud, J. -A.
    Zelenyi, L. M.
    JOURNAL OF GEOPHYSICAL RESEARCH-SPACE PHYSICS, 2016, 121 (10) : 9985 - 10004
  • [44] Temperature equilibration in a fully ionized plasma: Electron-ion mass ratio effects
    Brown, Lowell S.
    Singleton, Robert L., Jr.
    PHYSICAL REVIEW E, 2009, 79 (06):
  • [45] A THEORETICAL EVALUATION OF THE RELAXATION METHOD IN DETERMINING THE TEMPERATURE RATIO TE/TG IN AN INDUCTIVELY COUPLED PLASMA
    MILLER, GP
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1990, 45 (03) : 329 - 331
  • [46] Generalized Lenard-Balescu calculations of electron-ion temperature relaxation in beryllium plasma
    Fu, Zhen-Guo
    Wang, Zhigang
    Li, Da-Fang
    Kang, Wei
    Zhang, Ping
    PHYSICAL REVIEW E, 2015, 92 (03):
  • [47] Experimental investigation on time-resolved diagnosis of the electron temperature of line-plasmas
    Cai, Yuqin
    Yan, Shangjin
    Zhang, Qiren
    Chunyu, Shutai
    He, Yingling
    Zhang, Tanxin
    Hejubian Yu Dengliziti Wuli/Nuclear Fusion and Plasma Physics, 1993, 13 (01): : 56 - 60
  • [48] On electron temperature rise in divertor relevant recombining plasma along magnetic field line
    Takahashi, H.
    Winarto, M. N.
    Okamoto, A.
    Boonyarittipong, P.
    Seino, T.
    Kusabiraki, K.
    Sakata, Y.
    Yoshimura, K.
    Nishimura, R.
    Kitajima, S.
    Matsuyama, A.
    Tobita, K.
    PHYSICS OF PLASMAS, 2022, 29 (03)
  • [49] Argon 420.1-419.8 nm emission line ratio for measuring plasma effective electron temperatures
    Boffard, John B.
    Jung, R. O.
    Lin, Chun C.
    Aneskavich, L. E.
    Wendt, A. E.
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2012, 45 (04)
  • [50] Effect of electron and ion temperature ratio on Kinetic Alfven wave with homogeneous plasma by kinetic approach
    Agarwal, P.
    Varma, P.
    Tiwari, M. S.
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 2011, 49 (02) : 91 - 98