Theoretical calculations of isoelectronic line-ratio for plasma electron temperature diagnosis

被引:5
|
作者
Wu, ZQ [1 ]
Han, GX [1 ]
Yan, J [1 ]
Pang, JQ [1 ]
机构
[1] Inst Appl Phys & Computat Math, Beijing 100088, Peoples R China
关键词
D O I
10.1088/0256-307X/20/4/326
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
A model is developed to calculate the emission spectrum of non-local thermodynamic equilibrium (LTE) plasmas. The collisional-radiative model is adopted for non-LTE population calculations. Configuration-averaged rate coefficients that are needed in the rate equations are obtained based on the first-order perturbation theory. The Hartree-Fock-Slater self-consistent-field method is used to calculate electron wavefunctions. The present model is applied to the calculation of isoelectronic line-ratio of Cr and Ti, which is useful for plasma electron temperature diagnosis.
引用
收藏
页码:529 / 532
页数:4
相关论文
共 50 条
  • [1] Determination of the Electron Temperature by the Line-Ratio Method in SNF Plasma Separator
    Melnikov, A. D.
    Usmanov, R. A.
    Vorona, N. A.
    Gavrikov, A. V.
    Liziakin, G. D.
    Smirnov, V. P.
    Timirkhanov, R. A.
    PHYSICS OF ATOMIC NUCLEI, 2018, 81 (11) : 1536 - 1540
  • [2] Determination of the Electron Temperature by the Line-Ratio Method in SNF Plasma Separator
    A. D. Melnikov
    R. A. Usmanov
    N. A. Vorona
    A. V. Gavrikov
    G. D. Liziakin
    V. P. Smirnov
    R. A. Timirkhanov
    Physics of Atomic Nuclei, 2018, 81 : 1536 - 1540
  • [3] Effect of wall reflection on the determination of electron temperature by the line-ratio method in inductively coupled plasmas
    Pu, YK
    Yu, ZD
    Guo, ZG
    PHYSICS OF PLASMAS, 2005, 12 (11) : 1 - 3
  • [4] DEVELOPMENT OF AN ISOELECTRONIC LINE RATIO TECHNIQUE FOR IMPROVED DIAGNOSING OF TEMPERATURE AND TEMPERATURE GRADIENTS IN PHOTOIONZED PLASMA
    Lane, Theodore
    Flaugh, Matthew
    Koepke, Mark
    Steinberger, Thomas
    Loisel, Guillaume
    Bailey, James
    Rochau, Gregory
    2016 43RD IEEE INTERNATIONAL CONFERENCE ON PLASMA SCIENCE (ICOPS), 2016,
  • [5] ISOELECTRONIC LINE INTENSITY RATIOS FOR PLASMA ELECTRON-TEMPERATURE MEASUREMENT (INVITED)
    MARJORIBANKS, RS
    BUDNIK, F
    KULCSAR, G
    ZHAO, L
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (01): : 683 - 688
  • [6] Optical emission spectroscopy in low-temperature plasmas containing argon and nitrogen: determination of the electron temperature and density by the line-ratio method
    Zhu, Xi-Ming
    Pu, Yi-Kang
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2010, 43 (40)
  • [7] Plasma Parameters of a Gliding Arc Jet at Atmospheric Pressure Obtained by a Line-Ratio Method
    李辉
    谢铭丰
    Plasma Science and Technology, 2013, (08) : 776 - 779
  • [8] Plasma Parameters of a Gliding Arc Jet at Atmospheric Pressure Obtained by a Line-Ratio Method
    Li Hui
    Xie Mingfeng
    PLASMA SCIENCE & TECHNOLOGY, 2013, 15 (08) : 776 - 779
  • [9] ELECTRON-TEMPERATURE MEASUREMENT IN LASER-PRODUCED PLASMAS BY THE RATIO OF ISOELECTRONIC LINE-INTENSITIES
    MARJORIBANKS, RS
    RICHARDSON, MC
    JAANIMAGI, PA
    EPSTEIN, R
    PHYSICAL REVIEW A, 1992, 46 (04): : R1747 - R1750
  • [10] X-RAY LINE-RATIO PLASMA DIAGNOSTICS APPLIED TO SOLAR ACTIVE REGIONS
    MCKENZIE, DL
    JOURNAL DE PHYSIQUE, 1988, 49 (C-1): : 55 - 58