Verapamil quantification in human plasma by liquid chromatography coupled to tandem mass spectrometry - An application for bioequivalence study

被引:23
|
作者
Borges, NCD
Mendes, GD
Barrientos-Astigarraga, RE
Galvinas, P
Oliveira, CH
De Nucci, G
机构
[1] Univ Estadual Campinas, Dept Pharmacol, Campinas, SP, Brazil
[2] Cartesius Dev Clin Res, BR-13092320 Campinas, SP, Brazil
[3] Univ Estadual Campinas, Dept Internal Med, Campinas, SP, Brazil
关键词
Verapamil; bioequivalence; LC-MS/MS; metoprolol;
D O I
10.1016/j.jchromb.2005.07.012
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An analytical method based on liquid chromatography with positive ion electrospray ionization (ESI) coupled to tandem mass spectrometry detection (LC-MS/MS) was developed for the determination of Verapamil in human plasma using Metoprolol as the internal standard. The analyte and internal standard were extracted from the plasma samples by liquid-liquid extraction and chromatographed on a C-8 analytical column. The mobile phase consisted of methanol-water (70:30; v/v) + 12 mM formic acid. The method had a chromatographic total run time of 3.5 min and was linear within the range 1.00-500 ng/mL. Detection was carried out on a Micromass Quattro Ultima tandem mass spectrometer by multiple reaction monitoring (MRM). The intra-run imprecision was less than 5. 1 % calculated from the quality control (QC) samples, and 16.3% from the limit of quantification (LOQ). The accuracy determined from QC samples were between 92.9 and 103.1%, and 95.2 and 115.3% from LOQ. Concerning the inter-batch analysis, the imprecision was less than 5.8% and 17.3% from QC samples and LOQ, respectively. The accuracy varied between 98.2 and 100.8% from QC and it was 103. 1 % from LOQ. The protocol herein described was employed in a bioequivalence study of two tablet formulations of Verapamil. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:165 / 172
页数:8
相关论文
共 50 条
  • [31] QUANTITATIVE DETERMINATION OF MEMANTINE IN HUMAN PLASMA BY LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY: APPLICATION TO A BIOEQUIVALENCE STUDY
    Lou, Hong-gang
    Yu, Ling-yan
    Ruan, Zou-Rong
    Jiang, Bo
    Chen, Jin-liang
    [J]. JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2012, 35 (19) : 2696 - 2705
  • [32] Determination of levocetirizine in human plasma by liquid chromatography-electrospray tandem mass spectrometry: Application to a bioequivalence study
    Morita, M. R.
    Berton, D.
    Boldin, R.
    Barros, F. A. P.
    Meurer, E. C.
    Amarante, A. R.
    Campos, D. R.
    Calafatti, S. A.
    Pereira, R.
    Abib, E., Jr.
    Pedrazolli, J., Jr.
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 862 (1-2): : 132 - 139
  • [33] Determination of memantine in human plasma by liquid chromatography-electrospray tandem mass spectrometry: Application to a bioequivalence study
    Almeida, A. A.
    Campos, D. R.
    Bernasconi, G.
    Calafatti, S.
    Barros, F. A. P.
    Eberlin, M. N.
    Meurer, E. C.
    Paris, E. G.
    Pedrazzoli, J.
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 848 (02): : 311 - 316
  • [34] Quantification of teprenone in human plasma by HPLC coupled to mass spectrometry: Application to a bioequivalence study
    Ding, Jin-Song
    Zhou, Yan-Bin
    He, Juan
    Song, Jung
    Tan, Zhi-Rong
    [J]. CHROMATOGRAPHIA, 2007, 65 (9-10) : 533 - 538
  • [35] Determination of clindamycin in human plasma by liquid chromatography electrospray tandem mass spectrometry: application to the bioequivalence study of clindamycin
    Yu, LL
    Chao, CK
    Liao, WJ
    Twu, TY
    Liu, CM
    Yang, TH
    Lin, ET
    [J]. JOURNAL OF CHROMATOGRAPHY B, 1999, 724 (02): : 287 - 294
  • [36] Determination of itopride in human plasma by liquid chromatography coupled to tandem mass spectrometric detection: Application to a bioequivalence study
    Lee, Heon-Woo
    Seo, Ji-Hyung
    Choi, Seung-Ki
    Lee, Kyung-Tae
    [J]. ANALYTICA CHIMICA ACTA, 2007, 583 (01) : 118 - 123
  • [37] Quantification of Teprenone in Human Plasma by HPLC Coupled to Mass Spectrometry: Application to a Bioequivalence Study
    Ding Jin-Song
    Zhou Yan-Bin
    He Juan
    Song Juan
    Tan Zhi-Rong
    [J]. Chromatographia, 2007, 65 : 533 - 538
  • [38] Quantification of nimesulide in human plasma by high-performance liquid chromatography/tandem mass spectrometry.: Application to bioequivalence studies
    Barrientos-Astigarraga, RE
    Vannuchi, YB
    Sucupira, M
    Moreno, RA
    Muscará, MN
    De Nucci, G
    [J]. JOURNAL OF MASS SPECTROMETRY, 2001, 36 (12): : 1281 - 1286
  • [39] Bioequivalence Study of finasteride - Determination In human plasma by high-pressure liquid chromatography coupled to tandem mass spectrometry
    de Menezes, FG
    Ribeiro, W
    Ifa, DR
    de Moraes, MEA
    de Moraes, MOA
    De Nucci, G
    [J]. ARZNEIMITTEL-FORSCHUNG-DRUG RESEARCH, 2001, 51 (02): : 145 - 150
  • [40] Liquid Chromatography — Tandem Mass Spectrometry Method for Quantification of Zolpidem in Human Plasma: Application to Pharmacokinetic Study
    S. Dodda
    A. Makula
    S. R. Polagani
    R. N. Kandhagatla
    [J]. Journal of Applied Spectroscopy, 2020, 87 : 951 - 957