Acute biomechanical and histological effects of intradiscal electrothermal therapy on human lumbar discs

被引:56
|
作者
Kleinstueck, FS
Diederich, CJ
Nau, WH
Puttlitz, CM
Smith, JA
Bradford, DS
Lotz, JC
机构
[1] Univ Calif San Francisco, Orthopaed Bioengn Lab, Dept Orthopaed Surg, San Francisco, CA 94143 USA
[2] Univ Calif San Francisco, Dept Radiat Oncol, San Francisco, CA 94143 USA
关键词
biomechanics; heat; histology; hyperthermia; intervertebral disc; low back pain; lumbar vertebrae;
D O I
10.1097/00007632-200110150-00009
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Human cadaver lumbar spines were used to assess the acute effects of intradiscal electrothermal therapy in vitro. Objective. To determine whether intradiscal electrothermal therapy produces acute changes in disc histology and motion segment stability. Summary of Background Data. Intradiscal electrothermal therapy has been introduced as an alternative for the treatment of discogenic low back pain. Several hypothesized mechanisms for the effect of intradiscal electrothermal therapy have been suggested including shrinkage of the nucleus or sealing of the anulus fibrosus by contraction of collagen fibers, and thermal ablation of sensitive nerve fibers in the outer anulus. Methods. Intradiscal electrothermal therapy was performed with the Spinecath by Oratec on 19 fresh, frozen human lumbar cadaver specimens. In a separate study, eight specimens were tested biomechanically and instrumented to map the thermal distribution, whereas five specimens were tested only biomechanically, both before and after intradiscal electrothermal therapy. Six additional specimens were heated with intradiscal electrothermat therapy, and the resulting canal was backfilled with a silicone rubber compound to allow colocalization of the catheter and anular architecture. Results. A consistent pattern of increased motion and decreased stiffness was observed. For the specimens in which only biomechanical measurements were taken, a 10% increase in the motion, on the average, at 5 Nm torque was observed after intradiscal electrothermal therapy. No apparent alteration of the anular architecture was observed around the catheter site in the intradiscal electrothermal therapy-treated discs. Conclusion. The data from this study suggest that the temperatures developed during intradiscal electrothermat therapy are insufficient to alter collagen architecture or stiffen the treated motion segment acutely.
引用
收藏
页码:2198 / 2207
页数:10
相关论文
共 50 条
  • [21] Physiological effects of physical therapy interventions on lumbar intervertebral discs: A systematic review
    Mitchell, Ulrike H.
    Helgeson, Kevin
    Mintken, Paul
    PHYSIOTHERAPY THEORY AND PRACTICE, 2017, 33 (09) : 695 - 705
  • [22] Biological non-ablative repair of lumbar discs by transforaminal intradiscal laser irradiation: MRI quantitative analysis of the effects—preliminary report
    Igor Borshchenko
    Emil Sobol
    Anatoly Shekhter
    Andrey Baskov
    Andrey Grin
    Maria Borshchenko
    Lasers in Medical Science, 2022, 37 : 155 - 162
  • [23] Biomechanical effects of laminectomies in the human lumbar spine: a finite element study
    Spina, Nicholas T.
    Moreno, Genesis S.
    Brodke, Darrel S.
    Finley, Sean M.
    Ellis, Benjamin J.
    SPINE JOURNAL, 2021, 21 (01): : 150 - 159
  • [24] Biological non-ablative repair of lumbar discs by transforaminal intradiscal laser irradiation: MRI quantitative analysis of the effects-preliminary report
    Borshchenko, Igor
    Sobol, Emil
    Shekhter, Anatoly
    Baskov, Andrey
    Grin, Andrey
    Borshchenko, Maria
    LASERS IN MEDICAL SCIENCE, 2022, 37 (01) : 155 - 162
  • [25] Temperatures within the lumbar disc and endplates during intradiscal electrothermal therapy: Formulation of a predictive temperature map in relation to distance from the catheter - Point of view
    Lotz, JC
    Diederich, CJ
    SPINE, 2004, 29 (10) : 1130 - 1131
  • [26] Biomechanical Effects of Human Lumbar Discography In Vitro Experiments and Their Finite Element Validation
    Lipscomb, Kristen E.
    Sarigul-Klijn, Nesrin
    Klineberg, Eric
    Mohan, Vivek
    CLINICAL SPINE SURGERY, 2017, 30 (03): : E219 - E225
  • [27] Biomechanical comparison of the effects of anterior, posterior and transforaminal lumbar interbody fusion on vibration characteristics of the human lumbar spine
    Fan, Wei
    Guo, Li-Xin
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2019, 22 (05) : 490 - 498
  • [28] Histological changes and temperature distribution studies of a novel bipolar radiofrequency heating system in degenerated and nondegenerated human cadaver lumbar discs
    Kapural, Leonardo
    Mekhail, Nagy
    Hicks, David
    Kapural, Miranda
    Sloan, Steven
    Moghal, Nadeem
    Ross, Jeffrey
    Petrinec, Dejan
    PAIN MEDICINE, 2008, 9 (01) : 68 - 75
  • [29] Effects of backward bending on lumbar intervertebral discs - Relevance to physical therapy treatments for low back pain
    Adams, MA
    May, S
    Freeman, BJC
    Morrison, HP
    Dolan, P
    SPINE, 2000, 25 (04) : 431 - 437
  • [30] BIOMECHANICAL AND HISTOLOGICAL EFFECTS OF AUGMENTED SOFT TISSUE MOBILIZATION THERAPY ON ACHILLES TENDINOPATHY IN A RABBIT MODEL
    Imai, Kan
    Ikoma, Kazuya
    Chen, Qingshan
    Zhao, Chunfeng
    An, Kai-Nan
    Gay, Ralph E.
    JOURNAL OF MANIPULATIVE AND PHYSIOLOGICAL THERAPEUTICS, 2015, 38 (02) : 112 - 118