Novalis frameless image-guided noninvasive radiosurgery: Initial experience

被引:39
|
作者
Wurm, Reinhard E. [1 ]
Erbel, Stephan [1 ]
Schwenkert, Isabel [1 ]
Gum, Franz [1 ]
Agaoglu, Daniel [1 ]
Schild, Reinhard [1 ]
Schlenger, Lorenz [1 ]
Scheffler, Dirk [1 ]
Brock, Mario [2 ]
Budach, Volker [1 ]
机构
[1] Charite Univ Med Berlin, Dept Radiat Oncol, D-10117 Berlin, Germany
[2] Charite Univ Med Berlin, Dept Neurosurg, D-10117 Berlin, Germany
关键词
frameless; image-guided; linear accelerator; radiosurgery; stereotactic;
D O I
10.1227/01.neu.0000325932.34154.82
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE: To evaluate our initial experience with Novalis (BrainLAB, Heimstetten, Germany) frameless image-guided noninvasive radiosurgery. METHODS: The system combines the dedicated Novalis linear accelerator with ExacTrac X-Ray 6D, an infrared camera and a kilovolt stereoscopic x-ray imaging system, a noninvasive mask system, and ExacTrac robotics for patient positioning in six degrees of freedom. Reference cranial skeletal structures are radiographically imaged and automatically fused to digital reconstructed radiographs calculated from the treatment planning computed tomographic scan to find the target position and accomplish automatic real-time tracking before and during radiosurgery. We present the acceptance testing and initial experience in 15 patients with 19 intracranial lesions treated between December 2005 and June 2006 at the Charite by frameless image-guided radiosurgery with doses between 12 and 20 Gy prescribed to the target-encompassing isodose. RESULTS: Phantom tests showed an overall system accuracy of 1.04 +/- 0.47 mm, with an average in-plane deviation of 0.02 +/- 0.96 mm for the x-axis and 0.02 +/- 0.70 mm for the y-axis. After infrared-guided patient setup of all patients, the overall average translational deviation determined by stereoscopic x-ray verification was 1.5 +/- 1.3 mm, and the overall average rotational deviation was 1.0 +/- 0.8 degree. The data used for radiosurgery, after stereoscopic x-ray verification and correction, demonstrated an overall average setup error of 0.31 +/- 0.26 mm for translation and 0.26 +/- 0.23 degree for rotation. CONCLUSION: This initial evaluation demonstrates the system accuracy and feasibility of Novalis image-guided noninvasive radiosurgery for intracranial benign and malignant lesions.
引用
收藏
页码:A11 / A17
页数:7
相关论文
共 50 条
  • [11] EVALUATION OF IMAGE-GUIDED POSITIONING FOR FRAMELESS INTRACRANIAL RADIOSURGERY
    Lamba, Michael
    Breneman, John C.
    Warnick, Ronald E.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 74 (03): : 913 - 919
  • [12] INITIAL EXPERIENCE WITH USING FRAMELESS IMAGE - GUIDED RADIOSURGERY FOR THE TREATMENT OF BRAIN METASTASES
    Auslands, K.
    Liepa, Z.
    Apskalne, D.
    Ozols, R.
    [J]. NEURO-ONCOLOGY, 2012, 14 : 76 - 77
  • [13] Control of brain metastases using frameless image-guided radiosurgery
    Chen, Joseph C. T.
    Bugoci, Darlene M.
    Girvigian, Michael R.
    Miller, Michael J.
    Arellano, Alonso
    Rahimian, Javad
    [J]. NEUROSURGICAL FOCUS, 2009, 27 (06) : E6.1 - E6.7
  • [14] Patterns of patient movement during frameless image-guided radiosurgery
    Murphy, MJ
    Chang, SD
    Gibbs, IC
    Le, QT
    Hai, J
    Kim, D
    Martin, DP
    Adler, JR
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 55 (05): : 1400 - 1408
  • [15] The accuracy of dose localization for an image-guided frameless radiosurgery system
    Murphy, MJ
    Cox, RS
    [J]. MEDICAL PHYSICS, 1996, 23 (12) : 2043 - 2049
  • [16] Development of Image-Guided Radiosurgery with Novalis TX for Small Animal Study
    Yan, H.
    Koontz, B.
    Kimura, M.
    Vujaskovic, Z.
    Yin, F.
    [J]. MEDICAL PHYSICS, 2010, 37 (06)
  • [17] Frameless Image-Guided Radiosurgery for Multiple Brain Metastasis Using VMAT: A Review and an Institutional Experience
    Hanna, Samir Abdallah
    Mancini, Anselmo
    Dal Col, Alisson Henrique
    Asso, Rie Nadia
    Pimenta Neves-Junior, Wellington Furtado
    [J]. FRONTIERS IN ONCOLOGY, 2019, 9
  • [18] Localization Technique for Frameless Image-guided Robotic Radiosurgery of Arteriovenous Malformations
    Hristov, D. H.
    Liu, L.
    Moore, T.
    Dodd, R.
    Marks, M.
    Gibbs, I. C.
    Adler, J.
    Chang, S.
    Do, H.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S679 - S680
  • [19] Auditory feedback during frameless image-guided surgery in a phantom model and initial clinical experience
    Woerdeman, Peter A.
    Willems, Peter W. A.
    Noordmans, Herke Jan
    van der Sprenkel, Jan Willem Berkelbach
    [J]. JOURNAL OF NEUROSURGERY, 2009, 110 (02) : 257 - 262
  • [20] FRAMELESS IMAGE-GUIDED INTRACRANIAL STEREOTACTIC RADIOSURGERY: CLINICAL OUTCOMES FOR BRAIN METASTASES
    Breneman, John C.
    Steinmetz, Ryan
    Smith, Aaron
    Lamba, Michael
    Warnick, Ronald E.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 74 (03): : 702 - 706