Relationships between standard automated perimetry, HRT confocal scanning laser ophthalmoscopy, and GDx VCC scanning laser polarimetry

被引:41
|
作者
Reus, NJ [1 ]
Lemij, HG [1 ]
机构
[1] Rotterdam Eye Hosp, Glaucoma Serv, NL-3000 LM Rotterdam, Netherlands
关键词
D O I
10.1167/iovs.04-1029
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. This study was designed to determine and compare the relationships between visual function measured with standard automated perimetry (SAP) and structure, either as neuroretinal rim area measured with confocal scanning laser ophthalmoscopy (CSLO), or as retinal nerve fiber layer thickness determined by scanning laser polarimetry with variable corneal compensation (SLP-VCC). METHODS. Forty-six healthy subjects and 76 glaucoma patients were examined with SAP, with CSLO by means of the commercially available Heidelberg Retina Tomograph I (HRT), and with SLP-VCC by means of the commercially available GDx VCC. The relationships between SAP, expressed either in the typically used decibel scale or as number of abnormal points in the total deviation probability plot, and CSLO and between SAP and SLP-VCC were described with linear and logarithmic regression analysis for global data and six individual sectors. The relationship between measurements with CSLO and SLP-VCC was fit with linear regression analysis. RESULTS. The relationships between SAP and CSLO and between SAP and SLP-VCC appeared curvilinear for all sectors except the temporal one between SAP and SLP-VCC. For CSLO, a logarithmic fit was significantly better than a linear one for the global data and in the superotemporal and inferonasal sectors. For SLP-VCC, a curvilinear fit was better for the global data and in the superotemporal, superonasal, and inferonasal sectors. CSLO data correlated linearly with SLP-VCC data in all sectors, except temporally. CONCLUSIONS. CSLO and SLP-VCC showed a very similar curvilinear relationship with SAP. The observed curvilinear relationships confirm earlier reports that these imaging devices appear to detect glaucomatous loss earlier than SAP.
引用
收藏
页码:4182 / 4188
页数:7
相关论文
共 50 条
  • [1] Diagnostic laser in glaucoma:: scanning laser polarimetry (GDx VCC) and confocal scanning laser tomography (HRT)
    Renard, JP
    Giraud, JM
    May, F
    Rigal-Sastourné, JC
    Oubaaz, A
    Reda, K
    Maurin, JF
    [J]. JOURNAL FRANCAIS D OPHTALMOLOGIE, 2005, 28 (02): : 177 - 184
  • [2] Bayesian Estimation of the Performance of Frequency Doubling Perimetry (FDA, Confocal Scanning Laser Ophthalmoscopy (HRT) and GDx Variable Corneal Compensation (GDx-VCC) Scanning Laser Polarimetry for Glaucoma Screening in the Absence of a Gold Standard for Glaucoma Diagnosis
    Eid, C.
    Li, G.
    Fontaine, O.
    Lawrence, J.
    Harasymowycz, P. J.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [3] Comparison of GDx VCC and ECC scanning laser polarimetry with OCT and HRT
    Bonfioli, AA
    Wollstein, G
    Ishikawa, H
    Jones, BL
    Gabriele, M
    Dilworth, WD
    Eliash, Z
    Noecker, RJ
    Schuman, JS
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [4] The relationship between standard automated perimetry, GDx VCC, and HRT
    Lemij, HG
    Reus, NJ
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U667 - U667
  • [5] Correlation between confocal scanning laser ophthalmoscopy and scanning laser polarimetry in open angle glaucoma
    Sihota, R
    Gulati, V
    Saxena, R
    Agarwal, HC
    Sharma, AK
    [J]. EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2003, 13 (03) : 266 - 275
  • [6] Mapping structural to functional damage in glaucoma with standard automated perimetry and confocal scanning laser ophthalmoscopy
    Anton, A
    Yamagishi, N
    Zangwill, L
    Sample, PA
    Weinreb, RN
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1998, 125 (04) : 436 - 446
  • [7] Scanning laser polarimetry and confocal scanning laser ophthalmoscopy: technical notes on their use in glaucoma
    Ferreri, Felicia
    Aragona, Pasquale
    Ferreri, Giuseppe
    [J]. GLAUCOMA: AN OPEN WINDOW TO NEURODEGENERATION AND NEUROPROTECTION, 2008, 173 : 125 - 138
  • [8] Agreement and repeatability for standard automated perimetry and confocal scanning laser ophthalmoscopy in the Diagnostic Innovations in Glaucoma Study
    Ng, Diana
    Zangwill, Linda M.
    Racette, Lyne
    Bowd, Christopher
    Pascual, John P.
    Bourne, Rupert R. A.
    Boden, Catherine
    Weinreb, Robert N.
    Sample, Pamela A.
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 142 (03) : 381 - 386
  • [9] Comparison of GDx VCC scanning laser polarimeter, HRT II confocal scanning laser ophthalmoscope and StratusOCT optical coherence tomograph for glaucoma detection
    Medeiros, FA
    Bowd, C
    Zangwill, LM
    Weinreb, RN
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U128 - U128
  • [10] Combination of structural testing (GDx VCC scanning laser polarimetry, stratus optical coherence tomography [OCT], HRT II confocal scanning laser ophthalmoscopy) and functional testing (frequency doubling technology [FDT] perimetry) for detection of glaucoma in the diagnostic innovations in glaucoma study (DIGS)
    Shah, NN
    Medeiros, FA
    Sample, PA
    Bowd, C
    Hoffmann, EM
    Weinreb, RN
    Zangwill, LM
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46