An Algorithm for Effective Mitigation of Commutation Failure in High-Voltage Direct-Current Systems

被引:80
|
作者
Son, Ho-Ik [1 ]
Kim, Hak-Man [1 ]
机构
[1] Incheon Natl Univ, Dept Elect Engn, Inchon 22012, South Korea
关键词
Commutation failure; control mode ambiguity; extinction angle; high-voltage direct-current (HVDC) system; overlap angle; phase shift; HVDC; DESIGN; ANGLE;
D O I
10.1109/TPWRD.2016.2520928
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
High-voltage direct-current (HVDC) systems are being widely employed in various applications owing to their advantages, such as bulk power transmission, long-distance transmission, and power-flow control. However, HVDC systems suffer from-commutation failure, a major drawback that leads to increased device stress, interruptions in transmitted power, and problems related to protection relay setting, in turn, resulting in system instability during operation. Therefore, many studies have investigated the mitigation of commutation failure by considering its underlying factors, that is, ac voltage reduction, dc current increment, and crossing point shifts of phase voltage. However, these approaches are limited in that they are unable tomitigate intermittent commutation failure in a transient state. This study proposes an improved algorithm that mitigates commutation failure by considering the results of previous studies as well as the control characteristics of HVDC systems. The proposed algorithm is tested in various scenarios, and the test results verify its feasibility.
引用
收藏
页码:1437 / 1446
页数:10
相关论文
共 50 条
  • [31] TECHNICAL AND ECONOMIC DATA FOR OVERHEAD TRANSMISSION OF HIGH-VOLTAGE ALTERNATING-CURRENT AND DIRECT-CURRENT
    不详
    [J]. ELEKTROTECHNISCHE ZEITSCHRIFT ETZ-A, 1977, 98 (11): : 711 - 715
  • [32] Development of a sensor for corona current measurement under high-voltage direct-current transmission lines
    Xin, Encheng
    Yuan, Haiwen
    [J]. INTERNATIONAL JOURNAL OF DISTRIBUTED SENSOR NETWORKS, 2016, 12 (08):
  • [33] TECHNICAL AND ECONOMIC DATA FOR UNDERGROUND TRANSMISSION OF HIGH-VOLTAGE ALTERNATING-CURRENT AND DIRECT-CURRENT
    不详
    [J]. ELEKTROTECHNISCHE ZEITSCHRIFT ETZ-A, 1977, 98 (11): : 715 - 720
  • [34] A tool for power flow analysis of a generalized class of droop controllers for high-voltage direct-current transmission systems
    Zonetti, Daniele
    Ortega, Romeo
    Schiffer, Johannes
    [J]. 2016 IEEE 55TH CONFERENCE ON DECISION AND CONTROL (CDC), 2016, : 1564 - 1569
  • [35] BIBLIOGRAPHY ON HIGH-VOLTAGE DIRECT-CURRENT TRANSMISSION 1969-1976 .B.
    HWANG, HH
    IMAI, RM
    SIMMONS, TC
    [J]. IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1978, 97 (02): : 325 - 325
  • [36] Current-induced corrosion of aluminium heat sinks in water-cooling systems for high-voltage direct-current converters
    Liu, Xuezhong
    Wang, Chenxing
    Liu, Ning
    Jiao, Xiuying
    [J]. CORROSION ENGINEERING SCIENCE AND TECHNOLOGY, 2019, 54 (02) : 131 - 142
  • [37] HIGH-VOLTAGE PULSED DIRECT-CURRENT - EFFECT ON EDEMA FORMATION AFTER HYPERFLEXION INJURY
    BETTANY, JA
    FISH, DR
    MENDEL, FC
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1990, 71 (09): : 677 - 681
  • [38] INFLUENCE OF HIGH-VOLTAGE PULSED DIRECT-CURRENT ON EDEMA FORMATION FOLLOWING IMPACT INJURY
    BETTANY, JA
    FISH, DR
    MENDEL, FC
    [J]. PHYSICAL THERAPY, 1990, 70 (04): : 219 - 224
  • [39] Fault location in high-voltage direct-current grids based on panoramic voltage features and vision transformers
    Ren, Bo
    Luo, Yongjie
    Zhou, Niancheng
    Wang, Qianggang
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2024, 158
  • [40] MODULATION OF TRANSFER COEFFICIENT OF RESISTIVE SEPARATORS DURING MEASUREMENT OF HIGH-VOLTAGE DIRECT-CURRENT
    GRUDEV, KL
    [J]. PRIBORY I TEKHNIKA EKSPERIMENTA, 1972, (02): : 138 - &