Thermoluminescence dose response of photon irradiated NaCl: Unified interaction model analysis of the dependence of the supralinearity on photon energy

被引:9
|
作者
Druzhyna, S. [1 ]
Datz, H. [2 ]
Oster, L. [3 ]
Lerch, M. [4 ]
Rosenfeld, A. [4 ]
Cullen, A. [5 ]
Orion, I. [1 ]
Horowitz, Y. S. [6 ]
机构
[1] Ben Gurion Univ Negev, Nucl Engn Unit, Beer Sheva, Israel
[2] Soreq Nucl Res Ctr, Radiat Safety Div, Yavne, Israel
[3] Sami Shamoon Coll Engn, Phys Unit, Beer Sheva, Israel
[4] Univ Wollongong, Ctr Med Radiat Phys, Wollongong, NSW, Australia
[5] Wollongong Hosp, Illawarra Canc Care Ctr, Wollongong, NSW, Australia
[6] Ben Gurion Univ Negev, Phys Dept, Beer Sheva, Israel
关键词
Thermoluminescence; Retrospective dosimetry; NaCl; Dose response; UNIM;
D O I
10.1016/j.radmeas.2017.02.004
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The thermoluminescence (TL) dose response of a common Israeli table salt (NaCl) was measured following Cs-137 gamma ray and 125 kVp X-ray irradiation. The dose response is linear, then turns supralinear and finally enters into saturation. The phenomenon of TL linear/supralinear response and the dependence of the supralinearity on ionization density/photon energy is of major interest theoretically and also impacts the practical use of the material as a reliable dosimeter. Prior to this investigation only the supralinearity of the glow peaks of TLD-100 had been investigated. The supralinearity of the major glow peaks (peaks 3 and 5) of the investigated Nacl is strongly dependent on photon energy which lends credence to the probability that the ionization density dependence of TL supralinearity is a common if not universal phenomenon. The Unified Interaction Model used herein is based on the joint action of geminate and conduction band mediated recombination and was used to simulate the dose response of peaks 3 and 5. The simulated dose response allows a reliable estimate of the dose threshold where the supralinearity begins to appear. This information is useful in the evaluation of the Israeli salts as pragmatic retrospective dosimeters in the event of a radiological event. (c) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:455 / 458
页数:4
相关论文
共 50 条
  • [41] Analysis of some Pb, Th and U compounds in terms of photon interaction, photon energy absorption and fast neutron attenuation
    Kurudirek, Murat
    Ozdemir, Yuksel
    El-Khayatt, Ahmed Mahmoud
    RADIATION PHYSICS AND CHEMISTRY, 2011, 80 (08) : 855 - 862
  • [42] Energy dependence and dose response of Gafchromic EBT2 film over a wide range of photon, electron, and proton beam energies
    Arjomandy, Bijan
    Tailor, Ramesh
    Anand, Aman
    Sahoo, Narayan
    Gillin, Michael
    Prado, Karl
    Vicic, Milos
    MEDICAL PHYSICS, 2010, 37 (05) : 1942 - 1947
  • [43] Evaluation of Dose Rate and Photon Energy Dependence of Gafchromic EBT3 Film Irradiating with 6 MV and Co-60 Photon Beams
    Ataei, Gholamreza
    Rezaei, Maral
    Gorji, Ebrahimnejad
    Banaei, Amin
    Goushbolagh, Nouraddin Abdi
    Farhood, Bagher
    Bagheri, Mahmoud
    Firouzjah, Razzagh Abedi
    JOURNAL OF MEDICAL SIGNALS & SENSORS, 2019, 9 (03): : 204 - 210
  • [44] Energy and dose rate dependence of a diamond detector in the dosimetry of 4-25 MV photon beams
    Laub, WU
    Kaulich, TW
    Nusslin, F
    MEDICAL PHYSICS, 1997, 24 (04) : 535 - 536
  • [45] Energy and dose rate dependence of a diamond detector in the dosimetry of 4-25 MV photon beams
    Department of Medical Physics, University of Tübingen, D-72076 Tübingen, Germany
    MED. PHYS., 4 (535-536):
  • [46] Monte Carlo study of MOSFET dosemeter characteristics: Dose dependence on photon energy, direction and dosemeter composition
    Wang, B
    Xu, XG
    Kim, CH
    RADIATION PROTECTION DOSIMETRY, 2005, 113 (01) : 40 - 46
  • [47] Dosimetric evaluation of PASSAG-U polymer gel dosimeter: Dependence of dose rate and photon energy
    Farhood, Bagher
    Mohammadi, Kamal A. S. L.
    Sarvizadeh, Mostafa
    Aliasgharzadeh, Akbar
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2020, 28 (04) : 641 - 658
  • [48] Experimental photon energy response of different dosimetric materials for a dual detector system combining thermoluminescence and optically stimulated luminescence
    Malthez, Anna L. M. C.
    Freitas, Marcelo B.
    Yoshimura, Elisabeth M.
    Button, Vera L. S. N.
    RADIATION MEASUREMENTS, 2014, 71 : 133 - 138
  • [49] DEPENDENCE OF THE TSEE RESPONSE OF BEO THIN-FILMS ON PHOTON ENERGY AND COMPOSITION OF COVER MATERIALS
    KRIEGSEIS, W
    RAUBER, K
    SCHARMANN, A
    RITZENHOFF, KH
    CHARTIER, JL
    CUTARELLA, D
    ITIE, C
    PETEL, M
    RADIATION PROTECTION DOSIMETRY, 1993, 47 (1-4) : 143 - 146
  • [50] Monte Carlo study of the energy and angular dependence of the response of plastic scintillation detectors in photon beams
    Wang, Lille L. W.
    Klein, David
    Beddar, A. Sam
    MEDICAL PHYSICS, 2010, 37 (10) : 5279 - 5286