Towards an improved definition of periprocedural myocardial infarction: The role of high-sensitivity cardiac troponins

被引:1
|
作者
Heuts, Samuel [1 ]
van der Horst, Iwan C. C. [2 ,3 ]
Mingels, Alma [3 ,4 ]
机构
[1] Maastricht Univ, Med Ctr, Dept Cardiothorac Surg, NL-6229 HX Maastricht, Netherlands
[2] Maastricht Univ, Med Ctr, Dept Intens Care Med, Maastricht, Netherlands
[3] Maastricht Univ, Cardiovasc Res Inst Maastricht CARIM, Maastricht, Netherlands
[4] Maastricht Univ, Med Ctr, Cent Diagnost Lab, Maastricht, Netherlands
关键词
cardiac troponin; high-sensitivity cardiac troponin T; periprocedural myocardial infarction; MAGNETIC-RESONANCE; ELEVATION;
D O I
10.1111/jocs.16107
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In the past few years, many have disputed the optimal biomarker for confirming or ruling out a diagnosis of periprocedural myocardial infarction (PMI) and the optimal cut-off concentrations to apply. In this issue of the Journal of Cardiac Surgery, Niclauss et al. performed a retrospective analysis of CK-MB and high-sensitivity cardiac troponin T (hs-cTnT) dynamics and peak concentrations following different cardiac surgical interventions in 400 patients during a 2-year period in a single center. The authors found that CK-MB and hs-cTnT predict PMI with a comparable diagnostic accuracy and discriminatory power >95%. They also attempted to propose an improved, more sensitive threshold of hs-cTnT for PMI. Their findings could have implications for clinical practice, but more research is warranted to identify more appropriate cut-offs. This could include hs-cTnT release pattern, slope steepness, and changes. Ultimately, this could results in patient-specific model, able to predict expected and abnormal ranges of hs-cTnT release, enabling an improved and timely diagnosis of PMI.
引用
收藏
页码:162 / 164
页数:3
相关论文
共 50 条
  • [21] How to use high-sensitivity cardiac troponins in acute cardiac care
    Thygesen, Kristian
    Mair, Johannes
    Giannitsis, Evangelos
    Mueller, Christian
    Lindahl, Bertil
    Blankenberg, Stefan
    Huber, Kurt
    Plebani, Mario
    Biasucci, Luigi M.
    Tubaro, Marco
    Collinson, Paul
    Venge, Per
    Hasin, Yonathan
    Galvani, Marcello
    Koenig, Wolfgang
    Hamm, Christian
    Alpert, Joseph S.
    Katus, Hugo
    Jaffe, Allan S.
    EUROPEAN HEART JOURNAL, 2012, 33 (18) : 2252 - +
  • [22] Improved diagnostic performance of high-sensitivity cardiac troponins in muscle dystrophies using comprehensive definition criteria for cardiac involvement: A longitudinal study on 35 patients
    Yildirim, Mustafa
    Salbach, Christian
    Reich, Christoph
    Pribe-Wolferts, Regina
    Milles, Barbara Ruth
    Taeger, Tobias
    Mueller-Hennessen, Matthias
    Weiler, Markus
    Meder, Benjamin
    Frey, Norbert
    Giannitsis, Evangelos
    EUROPEAN JOURNAL OF NEUROLOGY, 2024, 31 (12)
  • [23] Direct comparison of three high-sensitivity cardiac troponins in syncope
    De lavallaz, J. Du Fay
    Badertscher, P. B.
    Zimmermann, T. Z.
    Walter, J. W.
    Strebel, I. S.
    Puelacher, C. P.
    Peacock, F. P.
    Boeddinghaus, J. B.
    Nestelberger, T. N.
    Geigy, N. G.
    Miro, O. M.
    Kuehne, M. K.
    Reichlin, T. R.
    Mueller, C. M.
    EUROPEAN HEART JOURNAL, 2019, 40 : 3544 - 3544
  • [24] Letter by Coscia et al Regarding Article, "High-Sensitivity Cardiac Troponin and the Universal Definition of Myocardial Infarction"
    Coscia, Tania
    Nestelberger, Thomas
    Mueller, Christian
    CIRCULATION, 2020, 141 (23) : E880 - E881
  • [25] High-sensitivity methods for cardiac troponins: The mission is not over yet
    Clerico, Aldo
    Zaninotto, Martina
    Passino, Claudio
    Padoan, Andrea
    Migliardi, Marco
    Plebani, Mario
    ADVANCES IN CLINICAL CHEMISTRY, VOL 103, 2021, 103 : 215 - 252
  • [26] Improving the performance of high-sensitivity cardiac troponin for the diagnosis of myocardial infarction
    Anand, A.
    Shah, A. S. V.
    Strachan, F. E.
    Lee, K. K.
    Chapman, A. R.
    Bularga, A.
    Stewart, S.
    Ferry, A.
    Marshall, L.
    Newby, D. E.
    Mills, N. L.
    EUROPEAN HEART JOURNAL, 2019, 40 : 2199 - 2199
  • [27] High-Sensitivity Cardiac Troponin on Presentation to Rule Out Myocardial Infarction
    Anand, Atul
    Lee, Kuan Ken
    Chapman, Andrew R.
    Ferry, Amy V.
    Adamson, Phil D.
    Strachan, Fiona E.
    Berry, Colin
    Findlay, Iain
    Cruikshank, Anne
    Reid, Alan
    Collinson, Paul O.
    Apple, Fred S.
    McAllister, David A.
    Maguire, Donogh
    Fox, Keith A. A.
    Newby, David E.
    Tuck, Chris
    Harkess, Ronald
    Keerie, Catriona
    Weir, Christopher J.
    Parker, Richard A.
    Gray, Alasdair
    Shah, Anoop S. V.
    Mills, Nicholas L.
    CIRCULATION, 2021, 143 (23) : 2214 - 2224
  • [28] Update on high-sensitivity cardiac troponin in patients with suspected myocardial infarction
    Twerenbold, Raphael
    Boeddinghaus, Jasper
    Mueller, Christian
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2018, 20 (0G) : G2 - G10
  • [29] Diagnostic Role of High-Sensitivity Cardiac Troponin T in Acute Myocardial Infarction and Cardiac Noncoronary Artery Disease
    Su, Qin
    Guo, Yingfei
    Liu, Hongsheng
    Qin, Yuhong
    Zhang, Jianbo
    Yuan, Xiaoling
    Zhao, Xiaodong
    ARCHIVES OF MEDICAL RESEARCH, 2015, 46 (03) : 193 - 198
  • [30] Response by Wereski et al to Letter Regarding Article, "High-Sensitivity Cardiac Troponin and the Universal Definition of Myocardial Infarction"
    Wereski, Ryan
    Mills, Nicholas L.
    Chapman, Andrew R.
    CIRCULATION, 2020, 141 (23) : E882 - E883