Preparation of 99Mo/99mTc generator based on cross-linked chitosan polymer using low-specific activity (n,γ)99Mo

被引:10
|
作者
Chattopadhyay, Sankha [1 ]
Das, Sujata Saha [1 ]
Alam, Md. Nayer [1 ]
Madhusmita [1 ]
机构
[1] VECC, Radiopharmaceut Lab, BRIT, 1 AF Bidhan Nagar, Kolkata 700064, India
关键词
Mo-99/Tc-99m generator; Cross-linked Chitosan polymer; Characterization; Mo-99; adsorption; Tc-99m elution efficiency; TC-99M; MO-99; TARGETS; COLUMN;
D O I
10.1007/s10967-017-5315-x
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The cross-linked chitosan polymer (CCM) is an emerging adsorbent matrix. The CCM matrix has very high adsorption for Mo and thus can be utilized to prepare Mo-99/Tc-99m generator using low-specific activity (n, gamma) Mo-99. The elution efficiency of Tc-99m from Mo-99/Tc-99m generator based on the CCM polymer oxidized and non-oxidized form has been found more than 75% and about 40%, respectively. The Na[Tc-99m]TcO4 eluates obtained were clear solutions with pH 5-6 and the R C Purities of 99%. The Mo-99 breakthrough in the Tc-99m fraction with alumina guard column (0.5 g) was 0.002 +/- 0.003 (n = 9). The radionuclidic purity of (TcO4)-Tc-99m (-) was more than 99.99%. The Al and Mo content in the eluted Tc-99m was less than 10 A mu g/ml. The R C Purity of the labeled compounds was greater than 95%.
引用
收藏
页码:647 / 653
页数:7
相关论文
共 50 条
  • [21] Diversification of 99Mo/99mTc Supply
    Dick, David
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55 (06) : 875 - 876
  • [22] Evaluation of highly loaded low specific activity 99Mo on alumina column as 99mTc generator
    M. Asif
    A. Mushtaq
    Journal of Radioanalytical and Nuclear Chemistry, 2010, 284 : 439 - 442
  • [23] Evaluation of highly loaded low specific activity 99Mo on alumina column as 99mTc generator
    Asif, M.
    Mushtaq, A.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2010, 284 (02) : 439 - 442
  • [24] Accelerator based 99Mo/99mTc production activity in Armenia
    Avagyan, R.
    Avetisyan, A.
    Kerobyan, I.
    Dallakyan, R.
    NUCLEAR MEDICINE AND BIOLOGY, 2014, 41 (07) : 648 - 649
  • [25] β-MoO3 Whiskers in 99Mo/99mTc Radioisotope Production and 99Mo/99mTc Extraction Using Hot Atoms
    Ngo, Minh Chu
    Fujita, Yoshitaka
    Suzuki, Tatsuya
    Do, Thi Mai Dung
    Seki, Misaki
    Nakayama, Tadachika
    Niihara, Koichi
    Suematsu, Hisayuki
    INORGANIC CHEMISTRY, 2023, 62 (32) : 13140 - 13147
  • [26] Preparation and performance of 99Mo/99mTc chromatographic column generator based on zirconium molybdosilicate
    Mostafa, M.
    Saber, H. M.
    El-Sadek, A. A.
    Nassar, M. Y.
    RADIOCHIMICA ACTA, 2016, 104 (04) : 257 - 265
  • [27] Successful Labeling of 99mTc-MDP Using 99mTc Separated from 99Mo Produced by 100Mo(n, 2n)99Mo
    Nagai, Yasuki
    Hatsukawa, Yuichi
    Kin, Tadahiro
    Hashimoto, Kazuyuki
    Motoishi, Shoji
    Konno, Chikara
    Ochiai, Kentaro
    Takakura, Kosuke
    Sato, Yuichi
    Kawauchi, Yukimasa
    Sato, Norihito
    Ohta, Akio
    Yamabayashi, Hisamichi
    Tanase, Masakazu
    Fujisaki, Saburo
    Teranaka, Tomoyuki
    Takeuchi, Nobuhiro
    Igarashi, Takashi
    JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN, 2011, 80 (08)
  • [28] RAPID DETERMINATION OF 99MO IN SEPARATED 99MTC
    RICHARDS, P
    OBRIEN, MJ
    JOURNAL OF NUCLEAR MEDICINE, 1969, 10 (07) : 517 - &
  • [29] CALCULATION OF 99Mo, 99MTc AND 99Tc IN THE GENERATOR AND IN THE ELUATE.
    Thieme, K.
    International journal of radiation applications and instrumentation. Part A, Applied radiation and isotopes, 1988, 39 (03): : 267 - 268
  • [30] Mechanism of 99Mo adsorption and 99mTc elution from zirconium-based material in 99Mo/99mTc generator column using neutron-irradiated natural molybdenum
    Awaludin, Rohadi
    Gunawan, AdangHardi
    Lubis, Hotman
    Sriyono
    Herlina
    Mutalib, Abdul
    Kimura, Akihiro
    Tsuchiya, Kunihiko
    Tanase, Masakazu
    Ishihara, Masahiro
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2015, 303 (02) : 1481 - 1483