Impact of Image Orientation on Measurements of Thyroid Nodule Stiffness Using Shear Wave Elastography

被引:11
|
作者
Gangadhar, Kiran [2 ]
Hippe, Daniel S. [1 ]
Thiel, Jeff [1 ]
Dighe, Manjiri [2 ]
机构
[1] Univ Washington, Dept Radiol, Seattle, WA 98195 USA
[2] Univ Washington, Body Imaging Sect, Seattle, WA 98195 USA
关键词
head and neck ultrasound; image orientation; shear wave elastography; thyroid nodule stiffness; TIME ULTRASOUND ELASTOGRAPHY; DIFFERENTIAL-DIAGNOSIS; PREDICTING MALIGNANCY; BENIGN; GLAND; PREVALENCE; ELASTICITY; US;
D O I
10.7863/ultra.15.10016
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives-To assess the effect of orientation on the stiffness measurement by shear wave elastography (SWE) within a thyroid nodule. Methods-Forty-five patients with 50 thyroid nodules were enrolled in this study. After a short sonographic examination, SWE images were acquired in transverse and longitudinal orientations. Multiple elastograms of each nodule were obtained in both orientations. Mean and maximum stiffness values were recorded from each region of interest. The overall mean and maximum stiffness values of each nodule were calculated for both orientations separately. The concordance correlation coefficient was used to assess overall agreement between measurements. A receiver operating characteristic curve analysis was conducted to assess diagnostic performance for benign versus malignant nodules. Results-The 45 patients included 6 men and 39 women (mean age, 53 years; range, 23-84 years). The mean stiffness values +/- SD were 19.1 +/- 18.4 and 20.9 +/- 21.5 kPa for transverse and longitudinal measurements, respectively, with a small overall bias between the orientations (1.8 kPa; P=.09). Overall agreement was good (concordance correlation coefficient, 0.93) although moderated somewhat after the stiffness values were log transformed to reduce skewness (concordance correlation coefficient, 0.76). Of the 50 nodules, 6 were classified as malignant. The area under the curve based on the mean stiffness value from longitudinal images tended to be better than for transverse images, but the difference was not statistically significant (0.93 versus 0.83; P =.17). Conclusions-Our study has shown that good diagnostic performance can be achieved by using SWE in longitudinal and transverse orientations. Moderate to good agreement in mean and maximum stiffness values for both orientations was observed, with only a small bias. Diagnostic performance for benign and malignant nodules was similar. The similar performance of both orientations gives flexibility in imaging patients with anatomic or physical limitations.
引用
下载
收藏
页码:1661 / 1667
页数:7
相关论文
共 50 条
  • [31] Comparison of liver stiffness assessment by transient elastography and shear wave elastography using six ultrasound devices
    Iijima, Hiroko
    Tada, Toshifumi
    Kumada, Takashi
    Kobayashi, Natsuko
    Yoshida, Masahiro
    Aoki, Tomoko
    Nishimura, Takashi
    Nakano, Chikage
    Ishii, Akio
    Takashima, Tomoyuki
    Sakai, Yoshiyuki
    Aizawa, Nobuhiro
    Nishikawa, Hiroki
    Ikeda, Naoto
    Iwata, Yoshinori
    Enomoto, Hirayuki
    Ide, Yoshi-Hiro
    Hirota, Seiichi
    Fujimoto, Jiro
    Nishiguchi, Shuhei
    HEPATOLOGY RESEARCH, 2019, 49 (06) : 676 - 686
  • [32] Shear wave elastography using sound touch elastography and supersonic shear imaging for liver measurements: a comparative study
    Xiang, Hongjin
    Ling, Wenwu
    Ma, Lin
    Yang, Lulu
    Lin, Tang
    Luo, Yan
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2022, 12 (05) : 2855 - 2865
  • [33] REPRODUCIBILITY OF NATURAL SHEAR WAVE ELASTOGRAPHY MEASUREMENTS
    Keijzer, Lana B. H.
    Strachinaru, Mihai
    Bowen, Dan J.
    Geleijnse, Marcel L.
    van der Steen, Antonius F. W.
    Bosch, Johan G.
    de Jong, Nico
    Vos, Hendrik J.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2019, 45 (12): : 3172 - 3185
  • [34] The Effects of Isometric Fatigue on Trunk Muscle Stiffness: Implications for Shear-Wave Elastography Measurements
    Vatovec, Rok
    Kozinc, Ziga
    Voglar, Matej
    SENSORS, 2022, 22 (23)
  • [35] Spleen stiffness measurements using point shear wave elastography detects noncirrhotic portal hypertension in human immunodeficiency virus
    Ahmad, Ayesha K.
    Atzori, Sebastiana
    Taylor-Robinson, Simon D.
    Maurice, James B.
    Cooke, Graham S.
    Garvey, Lucy
    MEDICINE, 2019, 98 (47)
  • [36] Shear wave elastography in medullary thyroid carcinoma diagnostics
    Dobruch-Sobczak, Katarzyna
    Guminska, Anna
    Bakula-Zalewska, Elwira
    Mlosek, Krzysztof
    Slapa, Rafal Z.
    Wareluk, Pawel
    Krauze, Agnieszka
    Ziemiecka, Agnieszka
    Migda, Bartosz
    Jakubowski, Wieslaw
    Dedecjus, Marek
    JOURNAL OF ULTRASONOGRAPHY, 2015, 15 (63) : 358 - 367
  • [37] Artifacts in Shear Wave Elastography Images of Thyroid Nodules
    Dighe, Manjiri
    Hippe, Daniel S.
    Thiel, Jeff
    Ultrasound in Medicine and Biology, 2018, 44 (06): : 1170 - 1176
  • [38] The Preciseness in Diagnosing Thyroid Malignant Nodules Using Shear-Wave Elastography
    Chang, Na
    Zhang, Xianchao
    Wan, Wenjing
    Zhang, Chengqi
    Zhang, Xianqi
    MEDICAL SCIENCE MONITOR, 2018, 24 : 671 - 677
  • [39] ARTIFACTS IN SHEAR WAVE ELASTOGRAPHY IMAGES OF THYROID NODULES
    Dighe, Manjiri
    Hippe, Daniel S.
    Thiel, Jeff
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2018, 44 (06): : 1170 - 1176
  • [40] The value of shear wave elastography in diffuse thyroid disease
    Liu, Jianxue
    Zhang, Yaoren
    Ji, Yonghao
    Wan, Qinyun
    Dun, Guoliang
    CLINICAL IMAGING, 2018, 49 : 187 - 192