Impact of Image Orientation on Measurements of Thyroid Nodule Stiffness Using Shear Wave Elastography

被引:11
|
作者
Gangadhar, Kiran [2 ]
Hippe, Daniel S. [1 ]
Thiel, Jeff [1 ]
Dighe, Manjiri [2 ]
机构
[1] Univ Washington, Dept Radiol, Seattle, WA 98195 USA
[2] Univ Washington, Body Imaging Sect, Seattle, WA 98195 USA
关键词
head and neck ultrasound; image orientation; shear wave elastography; thyroid nodule stiffness; TIME ULTRASOUND ELASTOGRAPHY; DIFFERENTIAL-DIAGNOSIS; PREDICTING MALIGNANCY; BENIGN; GLAND; PREVALENCE; ELASTICITY; US;
D O I
10.7863/ultra.15.10016
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives-To assess the effect of orientation on the stiffness measurement by shear wave elastography (SWE) within a thyroid nodule. Methods-Forty-five patients with 50 thyroid nodules were enrolled in this study. After a short sonographic examination, SWE images were acquired in transverse and longitudinal orientations. Multiple elastograms of each nodule were obtained in both orientations. Mean and maximum stiffness values were recorded from each region of interest. The overall mean and maximum stiffness values of each nodule were calculated for both orientations separately. The concordance correlation coefficient was used to assess overall agreement between measurements. A receiver operating characteristic curve analysis was conducted to assess diagnostic performance for benign versus malignant nodules. Results-The 45 patients included 6 men and 39 women (mean age, 53 years; range, 23-84 years). The mean stiffness values +/- SD were 19.1 +/- 18.4 and 20.9 +/- 21.5 kPa for transverse and longitudinal measurements, respectively, with a small overall bias between the orientations (1.8 kPa; P=.09). Overall agreement was good (concordance correlation coefficient, 0.93) although moderated somewhat after the stiffness values were log transformed to reduce skewness (concordance correlation coefficient, 0.76). Of the 50 nodules, 6 were classified as malignant. The area under the curve based on the mean stiffness value from longitudinal images tended to be better than for transverse images, but the difference was not statistically significant (0.93 versus 0.83; P =.17). Conclusions-Our study has shown that good diagnostic performance can be achieved by using SWE in longitudinal and transverse orientations. Moderate to good agreement in mean and maximum stiffness values for both orientations was observed, with only a small bias. Diagnostic performance for benign and malignant nodules was similar. The similar performance of both orientations gives flexibility in imaging patients with anatomic or physical limitations.
引用
下载
收藏
页码:1661 / 1667
页数:7
相关论文
共 50 条
  • [1] Variability in Stiffness Assessment in a Thyroid Nodule Using Shear Wave Imaging
    Brezak, Robert
    Hippe, Dan
    Thiel, Jeff
    Dighe, Manjiri K.
    ULTRASOUND QUARTERLY, 2015, 31 (04) : 243 - 249
  • [2] Analysis of the Influence of Thyroid Nodule Characteristics on the Results of Shear Wave Elastography
    Xue, Ji-ping
    Kang, Xiao-yan
    Miao, Jun-wang
    Zhang, Yan-xia
    Li, Hui-zhan
    Yao, Fu-cheng
    Kang, Chun-song
    FRONTIERS IN ENDOCRINOLOGY, 2022, 13
  • [3] Evaluation of the Stiffness of Tissues Surrounding Thyroid Nodules with Shear Wave Elastography
    Hu, Lei
    He, Nianan
    Ye, Lei
    Zhou, Hangcheng
    Zhong, Wen
    Zhang, Xinshu
    JOURNAL OF ULTRASOUND IN MEDICINE, 2018, 37 (09) : 2251 - 2260
  • [4] Guidelines and recommendations on the clinical use of shear wave elastography for evaluating thyroid nodule
    Xu, Hui-Xiong
    Yan, Kun
    Liu, Bo-Ji
    Liu, Wen-Ying
    Tang, Li-Na
    Zhou, Qi
    Wu, Jin-Yu
    Xue, En-Sheng
    Shen, Bin
    Tang, Qing
    Chen, Qin
    Xue, Hong-Yuan
    Li, Ying-Jia
    Guo, Jun
    Wang, Bin
    Li, Fang
    Yan, Chun-Yang
    Li, Quan-Shui
    Wang, Yan-Qing
    Zhang, Wei
    Wu, Chang-Jun
    Yu, Wen-Hui
    Zhou, Su-Jin
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2019, 72 (01) : 39 - 60
  • [5] Application of shear wave elastography in fine needle aspiration biopsy for thyroid nodule
    Ma, Bu Yun
    Parajuly, Shyam Sundar
    Ying, Shu Xue
    Lan, Peng Yu
    JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2014, 64 (08) : 954 - 957
  • [6] LIVER STIFFNESS AND CONTROLLED ATTENUATION PARAMETER MEASUREMENTS USING SHEAR WAVE BASED QUANTITATIVE ELASTOGRAPHY
    Sandrin, L.
    Miette, V.
    Sasso, M.
    ALCOHOL AND ALCOHOLISM, 2013, 48 : 9 - 9
  • [7] Artificial intelligence technology enhances the performance of shear wave elastography in thyroid nodule diagnosis
    Tuo, Jingmei
    Si, Xiaojuan
    Song, Heqin
    AMERICAN JOURNAL OF TRANSLATIONAL RESEARCH, 2023, 15 (10): : 6226 - 6233
  • [8] Assessing cardiac stiffness using ultrasound shear wave elastography
    Caenen, Annette
    Pernot, Mathieu
    Nightingale, Kathryn R.
    Voigt, Jens-Uwe
    Vos, Hendrik J.
    Segers, Patrick
    D'hooge, Jan
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (02):
  • [9] Interobserver Variability and Stiffness Measurements of Normal Lacrimal Gland in Healthy People Using Shear Wave Elastography
    Cerit, Mahinur
    Sendur, Halit Nahit
    CYPRUS JOURNAL OF MEDICAL SCIENCES, 2021, 6 (01): : 93 - 98
  • [10] Comparison of machine learned approaches for thyroid nodule characterization from shear wave elastography images
    Pereira, Carina
    Dighe, Manjiri
    Alessio, Adam M.
    MEDICAL IMAGING 2018: COMPUTER-AIDED DIAGNOSIS, 2018, 10575