Fabrication of a Urea Biosensor for Real-Time Dynamic Fluid Measurement

被引:26
|
作者
Kim, Kyunghee [1 ,2 ,3 ]
Lee, Jeongeun [1 ,2 ,3 ]
Moon, Bo Mi [4 ]
Seo, Ye Been [4 ]
Park, Chan Hum [4 ]
Park, Min [1 ,2 ,3 ]
Sung, Gun Yong [1 ,2 ,3 ]
机构
[1] Hallym Univ, Cooperat Course Nanomed Device Engn, Chunchon 24252, South Korea
[2] Hallym Univ, Dept Mat Sci & Engn, Chunchon 24252, South Korea
[3] Hallym Univ, Integrat Mat Res Inst, Chunchon 24252, South Korea
[4] Hallym Univ, Coll Med, Nanobio Regenerat Med Inst, Chunchon 24252, South Korea
基金
新加坡国家研究基金会;
关键词
urea biosensor; silk fibroin; amination; flow conditions; real-time monitoring; AMPEROMETRIC AMMONIUM ION; DIALYSIS THERAPY; ELECTRODE; CARBON; POLYANILINE; ACID; SENSOR; KOREA;
D O I
10.3390/s18082607
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, a portable urea sensor that monitors the urea concentration in flow conditions was fabricated. We propose an electrochemical sensor that continually measures the urea concentration of samples flowing through it at a constant flow rate in real time. For the electrochemical sensing, a porous silk fibroin membrane with immobilized urease was mounted in a polydimethylsiloxane (PDMS) sensor housing. The fabricated urea sensor elicited linear current-concentration characteristics in the clinically significant concentration range (0.1-20 mM) based on peritoneal dialysis. The sensor maintained the linear current-concentration characteristics during operation in flow conditions.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] A Graphenic Biosensor for Real-Time Monitoring of Urea During Dialysis
    Bonini, Andrea
    Vivaldi, Federico Maria
    Herrera, Elisa
    Melai, Bernardo
    Kirchhain, Arno
    Sajama, Noemi Violeta Poma
    Mattonai, Marco
    Caprioli, Raffaele
    Lomonaco, Tommaso
    Di Francesco, Fabio
    Salvo, Pietro
    IEEE SENSORS JOURNAL, 2020, 20 (09) : 4571 - 4578
  • [2] Real-time liquid crystal-based biosensor for urea detection
    Khan, Mashooq
    Kim, Youngkyoo
    Lee, Joon Hyung
    Kang, Inn-Kyu
    Park, Soo-Young
    ANALYTICAL METHODS, 2014, 6 (15) : 5753 - 5759
  • [3] Real-time liquid crystal-based biosensor for urea detection
    Park, Soo-Young
    Choi, Sung-Mun
    Lee, Jong-Hun
    Khan, Mashooq
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2014, 248
  • [4] Microelectrode biosensor for real-time measurement of ATP in biological tissue
    Llaudet, E
    Hatz, S
    Droniou, M
    Dale, N
    ANALYTICAL CHEMISTRY, 2005, 77 (10) : 3267 - 3273
  • [5] Real-time measurement of dynamic filament resistance
    Mortimer, GW
    JOURNAL OF THE ILLUMINATING ENGINEERING SOCIETY, 1998, 27 (01): : 22 - +
  • [6] Real-time measurement of dynamic filament resistance
    Mortimer, GW
    1996 IESNA ANNUAL CONFERENCE PROCEEDINGS TECHNICAL PAPERS, 1996, : 419 - 430
  • [7] Real-time fluid simulation in a dynamic virtual environment
    Chen, JX
    Lobo, ND
    Hughes, CE
    Moshell, JM
    IEEE COMPUTER GRAPHICS AND APPLICATIONS, 1997, 17 (03) : 52 - 61
  • [8] Real-Time Noninvasive Measurement of Glucose Concentration Using a Microwave Biosensor
    Bababjanyan, Arsen
    Melikyan, Harutyun
    Kim, Seungwan
    Kim, Jongchel
    Lee, Kiejin
    Friedman, Barry
    JOURNAL OF SENSORS, 2010, 2010
  • [9] Real-time measurement of endosomal acidification by a novel genetically encoded biosensor
    Michela Serresi
    Ranieri Bizzarri
    Francesco Cardarelli
    Fabio Beltram
    Analytical and Bioanalytical Chemistry, 2009, 393
  • [10] Real-Time Measurement of Endosomal Acidification by a Novel Genetically Encoded Biosensor
    Serresi, Michela
    BIOPHYSICAL JOURNAL, 2010, 98 (03) : 439A - 439A