Magnetic solid phase extraction coupled with high-performance liquid chromatography-diode array detection based on assembled magnetic covalent organic frameworks for selective extraction and detection of microcystins in aquatic foods

被引:16
|
作者
Wang, Tianliang [1 ]
Xie, Hongzhen [1 ]
Cao, Yuting [1 ]
Xu, Qing [1 ,2 ]
Gan, Ning [1 ,2 ]
机构
[1] Ningbo Univ, Sch Mat Sci & Chem Engn, Key Lab Adv Mass Spectrometry & Mol Anal Zhejiang, Ningbo 315211, Peoples R China
[2] Ningbo Univ, Fac Mat Sci & Chem Engn, Ningbo 315211, Zhejiang, Peoples R China
基金
中国国家自然科学基金;
关键词
Magnetic covalent organic frameworks; Microcystin; Magnetic solid phase extraction; Aquatic foods; HPLC-DAD; WATER; ADSORPTION; EFFICIENT; MICROEXTRACTION; ENRICHMENT; REMOVAL; MATRIX; ALGAE; LR;
D O I
10.1016/j.chroma.2022.463614
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
It is crucially important to develop simple, selective, and rapid extraction pretreatments and analytical methods to detect microcystins (MCs) in food samples with complex matrices. In this study, a magnetic self-assembled covalent organic framework (COF) adsorbent was synthesized via a facile approach by us-ing a one-pot reaction of 1,6-bis(4-formylphenyl)-3,8-bis(4-aminophenyl)pyrene (BFBAPy) as precursors to assemble amino-functionalized magnetic Fe3O4-NH2 nanoparticles (Fe3O4 @Py-COF, simplified as mCOF). The superparamagnetic mCOF is found to exhibit a high specific surface area, abundant nanopores and good stability. In particular, adsorption experiments demonstrate that mCOF exhibits a good adsorption capability, efficiency and some specificity to MCs. The mCOF was applied for magnetic solid phase extrac-tion (MSPE) of two kinds of MCs (MC-LR and MC-RR) from aquatic samples followed by high-performance liquid chromatography-diode array detection (HPLC-DAD). Under the optimized conditions, good linearity is obtained in the range of 10-10 0 0 mu g/kg (R 2 >= 0.9989), the limits of detection are 3.0-4.5 mu g/kg, and the relative standard deviations (RSDs) are lower than 4.9% (n = 5). The extraction recoveries are also satisfac-tory (84.2%-105%). These results demonstrate that the developed method can be used as a good alterna-tive method for the selective determination of MCs in complex aquatic foods.(c) 2022 Elsevier B.V. All rights reserved.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Determination of Aflatoxins in Tea by Magnetic Solid Phase Extraction Based on Covalent Organic Framework Coupled with High Performance Liquid Chromatography-Tandem Mass Spectrometry
    Zhao, Dongyue
    Xu, Xiuli
    Wang, Xiujuan
    Wu, Wei
    Zhang, Feng
    Shipin Kexue/Food Science, 2024, 45 (20): : 263 - 269
  • [32] Solid-Phase Extraction Combined with High Performance Liquid Chromatography-Diode Array Detector for Rapid Determination of Estrogens in Milk
    Yan, Qinghua
    Yang, Li
    Li, Sufang
    TROPICAL JOURNAL OF PHARMACEUTICAL RESEARCH, 2015, 14 (11) : 2077 - 2082
  • [33] Triazine-based covalent porous organic polymer for the online in-tube solid-phase microextraction of polycyclic aromatic hydrocarbons prior to high-performance liquid chromatography-diode array detection
    Feng, Jiaqing
    Feng, Juanjuan
    Han, Sen
    Ji, Xiangping
    Li, Chunying
    Sun, Min
    JOURNAL OF CHROMATOGRAPHY A, 2021, 1641
  • [34] Covalent organic frameworks as dispersive solid-phase extraction adsorbents for β-lactam detection in aquatic environments
    Hao, Weili
    Yin, Fanghua
    Wang, Ke
    Ma, Ling
    Lian, Kaoqi
    Shi, Hongmei
    MICROCHEMICAL JOURNAL, 2024, 202
  • [35] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH DIODE-ARRAY DETECTION FOR THE DETERMINATION OF PESTICIDES IN WATER USING AUTOMATED SOLID-PHASE EXTRACTION
    NOURI, B
    FOUILLET, B
    TOUSSAINT, G
    CHAMBON, P
    ANALYST, 1995, 120 (04) : 1133 - 1136
  • [36] Automated on-line solid-phase extraction high-performance liquid chromatography diode array detection of phenolic compounds in sherry wine
    Chilla, C
    Guillen, DA
    Barroso, CG
    PerezBustamante, JA
    JOURNAL OF CHROMATOGRAPHY A, 1996, 750 (1-2) : 209 - 214
  • [37] Preparation and quantification of the total phenolic products in Citrus fruit using solid-phase extraction coupled with high-performance liquid chromatography with diode array and UV detection
    Zeng, Honglian
    Liu, Zhenli
    Zhao, Siyu
    Shu, Yisong
    Song, Zhiqian
    Wang, Chun
    Dong, Yunzhuo
    Ning, Zhangchi
    He, Dan
    Wang, Menglei
    Lu, Cheng
    Liu, Yuanyan
    Lu, Aiping
    JOURNAL OF SEPARATION SCIENCE, 2016, 39 (19) : 3806 - 3817
  • [38] A multi-residue method for pesticide residue analysis in rice grains using matrix solid-phase dispersion extraction and high-performance liquid chromatography-diode array detection
    Tsochatzis, Emmanouil D.
    Menkissoglu-Spiroudi, Urania
    Karpouzas, Dimitrios G.
    Tzimou-Tsitouridou, Roxani
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 397 (06) : 2181 - 2190
  • [39] Determination of Estrogens in Milk Samples by Magnetic-Solid-Phase Extraction Technique Coupled With High-Performance Liquid Chromatography
    Wang, Juan
    Cheng, Chunsheng
    Yang, Yaling
    JOURNAL OF FOOD SCIENCE, 2015, 80 (12) : C2655 - C2661
  • [40] Simultaneous Determination of Tylosin Tartrate and Tylvalosin Tartrate in Wastewater by the Solid-Phase Extraction and High-Performance Liquid Chromatography-Diode Array Detector Method
    Chai, Ruina
    Cheng, Jianguo
    Zhang, Shuheng
    Ma, Litong
    Duan, Jianguo
    Zhao, Wenyuan
    Wang, Xiaoxia
    Fang, Chen
    SEPARATION SCIENCE PLUS, 2025, 8 (01):