Primary stability of self-tapping dual etched implants

被引:0
|
作者
Kassim, Zethy H. [1 ]
Nor Hisham, Nor D. [2 ]
Dardiri, Nur A. [2 ]
Goot Heah, Khor [3 ]
Hazwani Baharuddin, Izyan [3 ]
De Angelis, Nicola [1 ,4 ]
机构
[1] MARA Technol Univ, Fac Dent, Ctr Studies Restorat Dent, Jalan Hosp, Sungai Buloh, Malaysia
[2] Minist Hlth Malaysia, Putrajaya, Malaysia
[3] MARA Technol Univ, Fac Dent, Ctr Studies Preclin Sci, Jalan Hosp, Sungai Buloh, Malaysia
[4] Univ Genoa, Dept Surg Sci & Integrated Diagnost DISC, Largo R Benzi 10, I-16132 Genoa, Italy
来源
MINERVA STOMATOLOGICA | 2019年 / 68卷 / 06期
关键词
Dental implants; Osseointegration; Osteotomy; Validation studies; TRABECULAR BONE; OSSEOINTEGRATION; ANCHORAGE; DIAMETER; DENSITY; LENGTH;
D O I
10.23736/S0026-4970.19.04242-0
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
BACKGROUND: The aims of this study were to enumerate the primary implant stability quotient (ISQ) value of self-tapping dual etched implants and to explore the influence of parameters such as implant length, implant diameter, age, gender, implant location and osteotomy preparation on the ISQ value. METHODS: Retrospective data from clinical worksheets given to participants during two implant courses held between the periods of 2013 to 2014 were evaluated. A total of 61 implants were considered based on the inclusion criteria. The effects of parameters such as implant diameter, implant length, age, gender, implant location and osteotomy protocol on ISQ values were analyzed. RESULTS: Mean ISQ value for all implants was 67.21 +/- 9.13. Age of patients (P=0.016) and location of implants (P=0.041) had a significant linear relationship with the ISQ values. Within the age limit of the patients in this study, it was found that an increase in one year of patient's age results in 0.20 decrease in ISQ value (95% CI: -0.36, -0.04). However, placing an implant in the posterior maxilla may negatively affect the ISQ with a likely decrease in primary stability by 6.76 ISQ value (95% CI: -13.22, -0.30). CONCLUSIONS: The results suggest that the mean ISQ achieved by the participants were comparable with the range reported for this particular type of implants. The patient's age and location of implants were elucidated as the determinant factors of primary implant stability.
引用
收藏
页码:291 / 296
页数:6
相关论文
共 50 条
  • [21] Clinical study on the insertion torque and wireless resonance frequency analysis in the assessment of torque capacity and stability of self-tapping dental implants
    Kahraman, S.
    Bal, B. T.
    Asar, N. V.
    Turkyilmaz, I.
    Tozum, T. F.
    JOURNAL OF ORAL REHABILITATION, 2009, 36 (10) : 755 - 761
  • [22] SATISFACTION GRADE ASSESSMENT OF PATIENTS TREATED WITH ZYGOMATIC IMPLANTS WITH SELF-TAPPING APEX AND MACHINED BODY
    Scarano, A.
    Conte, R.
    Murmura, G.
    Lorusso, F.
    JOURNAL OF BIOLOGICAL REGULATORS AND HOMEOSTATIC AGENTS, 2019, 33 (05): : 1651 - 1656
  • [23] Quantifying Accuracy of Self-Tapping Screw Models
    Wilkie, Jack
    Docherty, Paul D.
    Stieglitz, Thomas
    Moeller, Knut
    2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 4391 - 4394
  • [24] No confidence that success rates of self-drilling and self-tapping insertion techniques of orthodontic mini-implants are similarQuestion: What are the success rates of self-drilling and self-tapping miniscrews in orthodontic treatment?
    Reint Meursinge Reynders
    Giorgio Cacciatore
    Evidence-Based Dentistry, 2016, 17 (4) : 111 - 113
  • [25] ASSEMBLING PLASTIC COMPONENTS WITH SELF-TAPPING SCREWS
    不详
    MANUFACTURING ENGINEERING & MANAGEMENT, 1972, 68 (03): : 33 - &
  • [26] Withdrawal strength of self-tapping screws in hardwoods
    Huebner, Ulrich
    PROCEEDINGS OF THE CIB - W18: WORKING COMMISSION W18 - TIMBER STRUCTURES, 2013, : 129 - 140
  • [27] AO/ASIF SELF-TAPPING SCREWS (STS)
    BAUMGART, FW
    CORDEY, J
    MORIKAWA, K
    PERREN, SM
    RAHN, BA
    SCHAVAN, R
    SNYDER, S
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1993, 24 : S1 - S17
  • [28] Pullout Performance of Self-Tapping Medical Screws
    Wu, Zhijun
    Nassar, Sayed A.
    Yang, Xianjie
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2011, 133 (11):
  • [29] Biomechanical finite element analysis of self-tapping implants with different dimensions inserted in two bone qualities
    Hasan, Istabrak
    Heinemann, Friedhelm
    Bourauel, Christoph
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2014, 59 (03): : 203 - 211
  • [30] Self-Drilling and Self-Tapping Screws: An Ultrastructural Study
    Goelzer, Juliana Goncalves
    Avelar, Rafael Linard
    de Oliveira, Rogerio Belle
    Hubler, Roberto
    Silveira, Roger Lanes
    Machado, Rosilene Andrea
    JOURNAL OF CRANIOFACIAL SURGERY, 2010, 21 (02) : 513 - 515