Primary stability of self-tapping dual etched implants
被引:0
|
作者:
Kassim, Zethy H.
论文数: 0引用数: 0
h-index: 0
机构:
MARA Technol Univ, Fac Dent, Ctr Studies Restorat Dent, Jalan Hosp, Sungai Buloh, MalaysiaMARA Technol Univ, Fac Dent, Ctr Studies Restorat Dent, Jalan Hosp, Sungai Buloh, Malaysia
Kassim, Zethy H.
[1
]
Nor Hisham, Nor D.
论文数: 0引用数: 0
h-index: 0
机构:
Minist Hlth Malaysia, Putrajaya, MalaysiaMARA Technol Univ, Fac Dent, Ctr Studies Restorat Dent, Jalan Hosp, Sungai Buloh, Malaysia
Nor Hisham, Nor D.
[2
]
Dardiri, Nur A.
论文数: 0引用数: 0
h-index: 0
机构:
Minist Hlth Malaysia, Putrajaya, MalaysiaMARA Technol Univ, Fac Dent, Ctr Studies Restorat Dent, Jalan Hosp, Sungai Buloh, Malaysia
Dardiri, Nur A.
[2
]
Goot Heah, Khor
论文数: 0引用数: 0
h-index: 0
机构:
MARA Technol Univ, Fac Dent, Ctr Studies Preclin Sci, Jalan Hosp, Sungai Buloh, MalaysiaMARA Technol Univ, Fac Dent, Ctr Studies Restorat Dent, Jalan Hosp, Sungai Buloh, Malaysia
Goot Heah, Khor
[3
]
Hazwani Baharuddin, Izyan
论文数: 0引用数: 0
h-index: 0
机构:
MARA Technol Univ, Fac Dent, Ctr Studies Preclin Sci, Jalan Hosp, Sungai Buloh, MalaysiaMARA Technol Univ, Fac Dent, Ctr Studies Restorat Dent, Jalan Hosp, Sungai Buloh, Malaysia
Hazwani Baharuddin, Izyan
[3
]
De Angelis, Nicola
论文数: 0引用数: 0
h-index: 0
机构:
MARA Technol Univ, Fac Dent, Ctr Studies Restorat Dent, Jalan Hosp, Sungai Buloh, Malaysia
Univ Genoa, Dept Surg Sci & Integrated Diagnost DISC, Largo R Benzi 10, I-16132 Genoa, ItalyMARA Technol Univ, Fac Dent, Ctr Studies Restorat Dent, Jalan Hosp, Sungai Buloh, Malaysia
De Angelis, Nicola
[1
,4
]
机构:
[1] MARA Technol Univ, Fac Dent, Ctr Studies Restorat Dent, Jalan Hosp, Sungai Buloh, Malaysia
[2] Minist Hlth Malaysia, Putrajaya, Malaysia
[3] MARA Technol Univ, Fac Dent, Ctr Studies Preclin Sci, Jalan Hosp, Sungai Buloh, Malaysia
[4] Univ Genoa, Dept Surg Sci & Integrated Diagnost DISC, Largo R Benzi 10, I-16132 Genoa, Italy
BACKGROUND: The aims of this study were to enumerate the primary implant stability quotient (ISQ) value of self-tapping dual etched implants and to explore the influence of parameters such as implant length, implant diameter, age, gender, implant location and osteotomy preparation on the ISQ value. METHODS: Retrospective data from clinical worksheets given to participants during two implant courses held between the periods of 2013 to 2014 were evaluated. A total of 61 implants were considered based on the inclusion criteria. The effects of parameters such as implant diameter, implant length, age, gender, implant location and osteotomy protocol on ISQ values were analyzed. RESULTS: Mean ISQ value for all implants was 67.21 +/- 9.13. Age of patients (P=0.016) and location of implants (P=0.041) had a significant linear relationship with the ISQ values. Within the age limit of the patients in this study, it was found that an increase in one year of patient's age results in 0.20 decrease in ISQ value (95% CI: -0.36, -0.04). However, placing an implant in the posterior maxilla may negatively affect the ISQ with a likely decrease in primary stability by 6.76 ISQ value (95% CI: -13.22, -0.30). CONCLUSIONS: The results suggest that the mean ISQ achieved by the participants were comparable with the range reported for this particular type of implants. The patient's age and location of implants were elucidated as the determinant factors of primary implant stability.