Calibration of Kodak EDR2 film for patient skin dose assessment in cardiac catheterization procedures

被引:13
|
作者
Morrell, RE [1 ]
Rogers, A [1 ]
机构
[1] City Hosp Nottingham, Med Phys Directorate, Nottingham NG5 1PB, England
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2004年 / 49卷 / 24期
关键词
D O I
10.1088/0031-9155/49/24/011
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Kodak EDR2 film has been calibrated across the range of exposure conditions encountered in our cardiac catheterization laboratory. Its dose-response function has been successfully modelled, up to the saturation point of 1 Gy. The most important factor affecting film sensitivity is the use of beam filtration. Spectral filtration and kVp together account for a variation in dose per optical density of -10% to +25%, at 160 mGy. The use of a dynamic wedge filter may cause doses to be underestimated by up to 6%. The film is relatively insensitive to variations in batch, field size, exposure rate, time to processing and day-to-day fluctuations in processor performance. Overall uncertainty in the calibration is estimated to be -20% to +40%, at 160 mGy. However, the uncertainty increases at higher doses, as the curve saturates. Artefacts were seen on a number of films, due to faults in the light-proofing of the film packets.
引用
下载
收藏
页码:5559 / 5570
页数:12
相关论文
共 37 条
  • [21] Measuring skin dose with radiochromic dosimetry film in the cardiac catheterization laboratory
    Giles, ER
    Murphy, PH
    HEALTH PHYSICS, 2002, 82 (06): : 875 - 880
  • [22] Patient skin dose in interventional procedures as measured by a portal film technique
    Kuan, HM
    Lawson, WE
    Manzione, JV
    Ferretti, JA
    Birk, JW
    Dignam, VA
    RADIOLOGY, 2000, 217 : 591 - 591
  • [23] Energy Dependency of Dose Response Function of An Optical Dosimeter and EDR2 Film for Spot-Scanning Proton and Carbon-Ionbeams
    Li, Y.
    Huang, Z.
    Hsi, W.
    MEDICAL PHYSICS, 2017, 44 (06)
  • [24] Direct measurement of a patient's entrance skin dose during pediatric cardiac catheterization
    Sun, Lue
    Mizuno, Yusuke
    Iwamoto, Mari
    Goto, Takahisa
    Koguchi, Yasuhiro
    Miyamoto, Yuka
    Tsuboi, Koji
    Chida, Koichi
    Moritake, Takashi
    JOURNAL OF RADIATION RESEARCH, 2014, 55 (06) : 1122 - 1130
  • [25] Correlation of patient maximum skin doses in cardiac procedures with various dose indicators
    Domienik, J.
    Papierz, S.
    Jankowski, J.
    Peruga, J. Z.
    Werduch, A.
    Religa, W.
    RADIATION PROTECTION DOSIMETRY, 2008, 132 (01) : 18 - 24
  • [26] Patient skin dose assessment during CT-guided interventional procedures
    Tsapaki, V.
    Triantopoulou, C.
    Maniatis, P.
    Kottou, S.
    Tsalafoutas, J.
    Papailiou, J.
    RADIATION PROTECTION DOSIMETRY, 2008, 129 (1-3) : 29 - 31
  • [27] Patient skin dose measurements during coronary interventional procedures using Gafchromic film
    Ying, C. K.
    Kandaiya, S.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2010, 30 (03) : 585 - 596
  • [28] Patient skin dose in cardiac interventional procedures: Conventional fluoroscopy versus pulsed fluoroscopy
    Chida, Koichi
    Fuda, Kenji
    Saito, Haruo
    Takai, Yoshihiro
    Takahashi, Shoki
    Yamada, Shogo
    Kohzuki, Masahiro
    Zuguchi, Masayuki
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2007, 69 (01) : 115 - 121
  • [29] Patient skin dose measurement and risk of deterministic effect during fluoroscopy cardiac procedures
    Nana, Ruth Njantang
    Inkoom, Stephen
    Moyo, Maurice Ndontchueng
    Mvoufo, Fokou
    Hasford, Francis
    Owusu-Manteaw, Philip
    Motapon, Ousmanou
    RADIATION PROTECTION DOSIMETRY, 2023, 199 (17) : 2053 - 2060
  • [30] Assessment of Maximum Patient Skin Dose for Interventional Radiology Procedures: Method and Uncertainty Analysis
    Farah, J.
    Trianni, A.
    Carinou, E.
    Dabin, J.
    Deangelis, C.
    Domienik, J.
    Knezevic, Z.
    Kopec, R.
    Malchair, F.
    Negri, A.
    Novak, L.
    Siiskonen, T.
    Vanhavere, F.
    Clairand, I.
    MEDICAL PHYSICS, 2013, 40 (06)