Calibration of Kodak EDR2 film for patient skin dose assessment in cardiac catheterization procedures

被引:13
|
作者
Morrell, RE [1 ]
Rogers, A [1 ]
机构
[1] City Hosp Nottingham, Med Phys Directorate, Nottingham NG5 1PB, England
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2004年 / 49卷 / 24期
关键词
D O I
10.1088/0031-9155/49/24/011
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Kodak EDR2 film has been calibrated across the range of exposure conditions encountered in our cardiac catheterization laboratory. Its dose-response function has been successfully modelled, up to the saturation point of 1 Gy. The most important factor affecting film sensitivity is the use of beam filtration. Spectral filtration and kVp together account for a variation in dose per optical density of -10% to +25%, at 160 mGy. The use of a dynamic wedge filter may cause doses to be underestimated by up to 6%. The film is relatively insensitive to variations in batch, field size, exposure rate, time to processing and day-to-day fluctuations in processor performance. Overall uncertainty in the calibration is estimated to be -20% to +40%, at 160 mGy. However, the uncertainty increases at higher doses, as the curve saturates. Artefacts were seen on a number of films, due to faults in the light-proofing of the film packets.
引用
下载
收藏
页码:5559 / 5570
页数:12
相关论文
共 37 条
  • [1] Kodak EDR2 film for patient skin dose assessment in cardiac catheterization procedures
    Morrell, R. E.
    Rogers, A. T.
    BRITISH JOURNAL OF RADIOLOGY, 2006, 79 (943): : 603 - 607
  • [2] Effect of processing time delay on the dose response of Kodak EDR2 film
    Childress, NL
    Rosen, II
    MEDICAL PHYSICS, 2004, 31 (08) : 2284 - 2288
  • [3] Evaluation of Kodak EDR2 film and its application in IMRT dose verification
    Nguyen, N
    Higgins, P
    Alaei, P
    MEDICAL PHYSICS, 2002, 29 (06) : 1269 - 1269
  • [4] Comprehensive evaluation of Kodak's EDR2 film for depth dose dosimetry
    Dogan, N
    Leybovich, LB
    Sethi, A
    MEDICAL PHYSICS, 2002, 29 (06) : 1367 - 1367
  • [5] Effect of processing time delay on the dose response of Kodak EDR2 film
    Childress, N
    Rosen, I
    MEDICAL PHYSICS, 2004, 31 (06) : 1822 - 1822
  • [6] EDR2 Film for Skin Dose Measurement in Coronary Angiography
    Ying, C. K.
    Kandaiya, S.
    SAINS MALAYSIANA, 2012, 41 (01): : 133 - 140
  • [7] Dosimetric accuracy of Kodak EDR2 film for IMRT verifications
    Childress, NL
    Salehpour, M
    Dong, L
    Bloch, C
    White, RA
    Rosen, II
    MEDICAL PHYSICS, 2005, 32 (02) : 539 - 548
  • [8] Kodak EDR2 film dosimetry: Effects of film orientation and phantom density
    Hsi, WC
    Chu, JCH
    Bernard, D
    MEDICAL PHYSICS, 2003, 30 (06) : 1478 - 1478
  • [9] A mathematical model for patient skin dose assessment in cardiac catheterization procedures
    Morrell, R. E.
    Rogers, A. T.
    BRITISH JOURNAL OF RADIOLOGY, 2006, 79 (945): : 756 - 761
  • [10] Clinical experience with Kodak EDR2 film for patient-specific IMRT quality assurance
    Childress, N
    Rosen, I
    MEDICAL PHYSICS, 2003, 30 (06) : 1501 - 1502