The ultrahigh flux polarized cold neutron spectrometer PANDA of the FRM-II reactor

被引:5
|
作者
Loewenhaupt, M [1 ]
Pyka, NM
机构
[1] Tech Univ Dresden, Inst Angew Phys, D-01062 Dresden, Germany
[2] Tech Univ Munich, Forschungsheutronenquelle FRM 2, D-85747 Garching, Germany
关键词
D O I
10.1063/1.369105
中图分类号
O59 [应用物理学];
学科分类号
摘要
At present the high flux research reactor FRM-II is under construction in Garching, Germany. As part of the first set of instruments, a triple axis spectrometer is under construction at the cold source in the reactor hall. This instrument will be mainly used to study inelastic magnetic phenomena in condensed matter physics. Besides an unpolarized beam setup, PANDA is equipped with devices allowing full polarization analysis. This instrument largely profits from its vicinity to the reactor, and uses state of the art neutron optics. Thanks to the large focusing Heusler monochromator and analyzer the neutron flux of the polarization setup will be of the same magnitude as that of an unpolarized beam at a high flux reactor. The accessible energy and Q ranges will be extremely large due to an advantageous flux distribution of the cold source and a particular construction of the beam tube and the biological shielding which contain supermirror neutron guides. A resonant spin echo device, used to perform line shape analysis of dispersive excitations, will complete the extensive array of equipment, available on PANDA. (C) 1999 American Institute of Physics. [S0021-8979(99)21708-2].
引用
收藏
页码:5145 / 5147
页数:3
相关论文
共 50 条
  • [31] Intense positron source at the Munich research reactor FRM-II
    Hugenschmidt, C
    Kögel, G
    Repper, R
    Schreckenbach, K
    Sperr, P
    Strasser, B
    Triftshäuser, W
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2002, 74 (Suppl 1): : S295 - S297
  • [32] Intense positron source at the Munich research reactor FRM-II
    Hugenschmidt, C
    Kögel, G
    Schreckenbach, K
    Sperr, P
    Strasser, B
    Triftshäuser, W
    POSITRON ANNIHILATION - ICPA-12, 2001, 363-3 : 425 - 429
  • [33] The design of the neutron radiography and tomography facility at the new research reactor FRM-II at Technical University Munich
    Schillinger, B
    Calzada, E
    Grünauer, F
    Steichele, E
    APPLIED RADIATION AND ISOTOPES, 2004, 61 (04) : 653 - 657
  • [34] Reactivity effects and neutron flow densities in experimental units of FRM-II
    Gaubatz, W
    Gallmeier, FX
    ANNUAL MEETING ON NUCLEAR TECHNOLOGY '97, 1997, : 581 - 584
  • [35] The backscattering spectrometer for the FRM II reactor in Munich
    Kirstein, O
    Kozielewski, T
    Prager, M
    Grimm, H
    Richter, D
    PHYSICA B-CONDENSED MATTER, 2000, 291 (3-4) : 310 - 313
  • [36] Monoenergetic positron beam at the reactor based positron source at FRM-II
    Hugenschmidt, C
    Kögel, G
    Repper, R
    Schreckenbach, K
    Sperr, P
    Strasser, B
    Triftshäuser, W
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2002, 192 (1-2): : 97 - 101
  • [37] High resolution stroboscopic neutron radiography at the FRM-II ANTARES facility
    Tremsin, Anton S.
    Muehlbauer, Martin J.
    Schillinger, Burkhard
    McPhate, Jason B.
    Vallerga, John V.
    Siegmund, Oswald H. W.
    Feller, W. Bruce
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 4026 - +
  • [38] SPHERES, Julich's high-flux neutron backscattering spectrometer at FRM II
    Wuttke, Joachim
    Budwig, Alfred
    Drochner, Matthias
    Kaemmerling, Hans
    Kayser, Franz-Joseph
    Kleines, Harald
    Ossovyi, Vladimir
    Carlos Pardo, Luis
    Prager, Michael
    Richter, Dieter
    Schneider, Gerald J.
    Schneider, Harald
    Staringer, Simon
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (07):
  • [39] Status and safety concept of the new German research reactor FRM-II
    Böning, K
    Axmann, A
    Blombach, J
    PROCEEDINGS OF THE INTERNATIONAL TOPICAL MEETING ON ADVANCED REACTORS SAFETY, VOLS 1 AND 2, 1997, : 646 - 656
  • [40] Image reconstruction and multiple hole apertures in neutron radiography at FRM-II
    Gruenauer, Florian
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 566 (02): : 654 - 661