Pacemaker therapy in premature children with high degree AV block

被引:7
|
作者
Nowak, B
Kampmann, C
Schmid, FX
Przibille, O
Wippermann, F
Himmrich, E
Meyer, J
机构
[1] Univ Mainz, Med Clin 2, D-55131 Mainz, Germany
[2] Univ Mainz, Dept Pediat Cardiol, D-55131 Mainz, Germany
[3] Univ Mainz, Dept Cardiothorac Surg, D-55131 Mainz, Germany
来源
关键词
epicardial pacing; steroid-elution; children; Autocapture;
D O I
10.1111/j.1540-8159.1998.tb00052.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The smallest pacemaker pulse generator and a steroid-eluting bipolar epicardial lead were implanted in two premature children with symptomatic AV block. Stable capture threshold and high amplitude evoked response electrogram resulted in normal function of the pacemaker Autocapture algorithm, which adjusts output 0.3 V above the measured capture threshold. Autocapture had previously been used only with endocardial leads. Longer-term observation is required.
引用
收藏
页码:2695 / 2698
页数:4
相关论文
共 50 条
  • [21] INDICATION FOR PROPHYLACTIC PACEMAKER INSERTION IN PATIENTS WITH HIGH DEGREE AV CONDUCTION DISTURBANCES
    PROBST, P
    ZEITSCHRIFT FUR KARDIOLOGIE, 1975, 64 (10): : 926 - 933
  • [22] Exposure to Glucocorticoids Prior to Transcatheter Aortic Valve Replacement is Associated with Reduced Incidence of High-Degree AV block and Pacemaker
    Oestreich, Brett
    Adabag, Selcuk
    Kelly, Rosemary
    Helmer, Gregory
    Raveendran, Ganesh
    Yannopoulos, Demetris
    Biring, Timinder
    Garcia, Santiago
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 70 (18) : B230 - B230
  • [23] Exposure to glucocorticoids prior to transcatheter aortic valve replacement is associated with reduced incidence of high-degree AV block and pacemaker
    Oestreich, Brett
    Gurevich, Sergey
    Adabag, Selcuk
    Kelly, Rosemary
    Helmer, Gregory
    Raveendran, Ganesh
    Yannopoulos, Demetris
    Biring, Timinder
    Garcia, Santiago
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2019, 20 (04) : 328 - 331
  • [24] Reversibility of High Degree Av Block in Hypertensive and Diabetic Patient with Unstable Angina Pectoris. Should We Delay the Pacemaker?
    Hanifah
    Puryani, A.
    Darkuthni, F. R.
    Hasanuddin
    Chairiadi, V.
    JOURNAL OF HYPERTENSION, 2024, 42 (SUPPL 2)
  • [25] PACEMAKER THERAPY IN CHILDREN WITH COMPLETE HEART-BLOCK
    STANTON, RE
    LINDESMITH, GG
    MEYER, BW
    AMERICAN JOURNAL OF DISEASES OF CHILDREN, 1975, 129 (04): : 484 - 487
  • [26] COMPLETE HEART-BLOCK AND PACEMAKER THERAPY IN CHILDREN
    STOERMER, J
    SCHRAMM, G
    MONATSSCHRIFT KINDERHEILKUNDE, 1979, 127 (12) : 697 - 701
  • [28] Pacemaker programming in patients with first-degree AV-block: Programming pattern and possible consequences
    Holmqvist, F.
    Rathakrishnan, B.
    Jackson, L. R.
    Campbell, K.
    Daubert, J. P.
    HEALTH SCIENCE REPORTS, 2018, 1 (06)
  • [29] High degree AV block complicating cardiac surgery or interventional catheterization: Longterm follow-up of underlying AV-conduction status after pacemaker implantation
    Kindermann, M
    Schwaab, B
    Frohlig, G
    Schieffer, H
    HEARTWEB, 1998, 3 (02): : U39 - U46
  • [30] “First-degree AV block—a benign entity?” Insertable cardiac monitor in patients with 1st-degree AV block reveals presence or progression to higher grade block or bradycardia requiring pacemaker implant
    Thorsten Lewalter
    Helmut Pürerfellner
    Andrea Ungar
    Guido Rieger
    Lorenza Mangoni
    Firat Duru
    Journal of Interventional Cardiac Electrophysiology, 2018, 52 : 303 - 306