Robust dynamic susceptibility contrast MR perfusion using 4D nonlinear noise filters

被引:15
|
作者
Kosior, Jayme Cameron [1 ,2 ]
Kosior, Robert Karl [1 ,2 ]
Frayne, Richard [1 ,2 ,3 ]
机构
[1] Univ Calgary, Foothills Med Ctr, Seaman Family MR Res Ctr, Dept Radiol, Calgary, AB T2N 2T9, Canada
[2] Univ Calgary, Dept Elect & Comp Engn, Calgary, AB, Canada
[3] Univ Calgary, Dept Clin Neurosci, Calgary, AB, Canada
关键词
dynamic susceptibility contrast (DSC); cerebral blood flow (CBF); spatiotemporal noise filtering; perfusion phantom; acute ischemic stroke;
D O I
10.1002/jmri.21219
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate if 4D (simultaneous space and time) nonlinear filtering techniques can produce more robust cerebral blood flow (CBF) estimates by reducing noise in acquired dynamic susceptibility contrast (DSC) MR perfusion data. Materials and Methods: A digital anthropomorphic brain per-fusion phantom was constructed to analyze filter performance by: 1) deriving anthropomorphic tissue volume fractions from a human subject and 2) simulating DSC-MR perfusion signals for voxels with mixed tissue for various signal-to-noise ratios (SNRs). DSC-MR data for 11 acute ischemic stroke patients were also acquired at 3T. CBF maps cross-calibrated so that normal white matter CBF was 22 mL/minute/100 g were produced from DSC-MR data without filtering and from 4D-Gaussian and 4D-bilateral noise-filtered DSC-MR data. Results: The nonlinear 4D-bilateral filter yielded the lowest CBF root-mean square error (RMSE) in the phantom experiments with noise (average RMSE across all tissues regions for no filtering. 4D-Gaussian, and 4D-bilateral was 5.3 mL/ minute/ 100 g, 6.2 mL/minute/100 g, and 4.0 mL/minute/100 g. respectively) and had the best image quality in both the phantom and patient data. Conclusion: Nonlinear 4D noise filters are better suited to the 4D nature of DSC-MR data. Linear spatial filters are not appropriate and can produce larger CBF errors than without filtering.
引用
收藏
页码:1514 / 1522
页数:9
相关论文
共 50 条
  • [1] Perfusion Dynamic Susceptibility Contrast and Dynamic Contrast-Enhanced MR Imaging
    Ibrahim, Mohannad
    Ul Ghazi, Talha
    Bapuraj, Jayapalli Rajiv
    Srinivasan, Ashok
    [J]. MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2021, 29 (04) : 515 - 526
  • [2] Pitfalls and Artifacts in Dynamic Susceptibility Contrast MR Perfusion of Brain
    Mangla, R.
    Ekholm, S.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (05)
  • [3] 4D MR imaging using robust internal respiratory signal
    Hui, CheukKai
    Wen, Zhifei
    Stemkens, Bjorn
    Tijssen, R. H. N.
    van den Berg, C. A. T.
    Hwang, Ken-Pin
    Beddar, Sam
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (09): : 3472 - 3487
  • [4] A Machine Learning Approach to Perfusion Imaging With Dynamic Susceptibility Contrast MR
    McKinley, Richard
    Hung, Fan
    Wiest, Roland
    Liebeskind, David S.
    Scalzo, Fabien
    [J]. FRONTIERS IN NEUROLOGY, 2018, 9
  • [5] Contrast and motion artifacts in 4D MR angiography
    Mistretta, CA
    Grist, TM
    Frayne, R
    Korosec, FR
    [J]. RADIOLOGY, 1996, 201 : 1086 - 1086
  • [6] Improved dynamic susceptibility contrast (DSC)-MR perfusion estimates by motion correction
    Kosior, Robert K.
    Kosior, Jayme C.
    Frayne, Richard
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (04) : 1167 - 1172
  • [7] Dynamic susceptibility MR perfusion imaging of the brain: not a question of contrast agent molarity
    Valentina Panara
    Piero Chiacchiaretta
    Matteo Rapino
    Valerio Maruotti
    Matteo Parenti
    Eleonora Piccirilli
    Andrea Delli Pizzi
    Massimo Caulo
    [J]. Neuroradiology, 2022, 64 : 685 - 692
  • [8] Dynamic susceptibility MR perfusion imaging of the brain: not a question of contrast agent molarity
    Panara, Valentina
    Chiacchiaretta, Piero
    Rapino, Matteo
    Maruotti, Valerio
    Parenti, Matteo
    Piccirilli, Eleonora
    Pizzi, Andrea Delli
    Caulo, Massimo
    [J]. NEURORADIOLOGY, 2022, 64 (04) : 685 - 692
  • [9] Signal-to-noise ratio effects in quantitative cerebral perfusion using dynamic susceptibility contrast agents
    Smith, MR
    Lu, H
    Frayne, R
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (01) : 122 - 128
  • [10] ASFNR Recommendations for Clinical Performance of MR Dynamic Susceptibility Contrast Perfusion Imaging of the Brain
    Welker, K.
    Boxerman, J.
    Kalnin, A.
    Kaufmann, T.
    Shiroishi, M.
    Wintermark, M.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2015, 36 (06) : E41 - E51