A Machine Learning Approach to Perfusion Imaging With Dynamic Susceptibility Contrast MR

被引:28
|
作者
McKinley, Richard [1 ]
Hung, Fan [2 ]
Wiest, Roland [1 ]
Liebeskind, David S. [2 ]
Scalzo, Fabien [2 ]
机构
[1] Univ Bern, Inselspital, Support Ctr Adv Neuroimaging, Bern, Switzerland
[2] Univ Calif Los Angeles, Dept Neurol, Los Angeles, CA 90024 USA
来源
FRONTIERS IN NEUROLOGY | 2018年 / 9卷
基金
瑞士国家科学基金会;
关键词
machine learning; stroke; perfusion; reperfusion; penumbra; STROKE; QUANTIFICATION; PENUMBRA; FLOW;
D O I
10.3389/fneur.2018.00717
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: Dynamic susceptibility contrast (DSC) MR perfusion is a frequently-used technique for neurovascular imaging. The progress of a bolus of contrast agent through the tissue of the brain is imaged via a series of T2*-weighted MRI scans. Clinically relevant parameters such as blood flow and Tmax can be calculated by deconvolving the contrast-time curves with the bolus shape (arterial input function). In acute stroke, for instance, these parameters may help distinguish between the likely salvageable tissue and irreversibly damaged infarct core. Deconvolution typically relies on singular value decomposition (SVD): however, studies have shown that these algorithms are very sensitive to noise and artifacts present in the image and therefore may introduce distortions that influence the estimated output parameters. Methods: In this work, we present a machine learning approach to the estimation of perfusion parameters in DSC-MRI. Various machine learning models using as input the raw MR source data were trained to reproduce the output of an FDA approved commercial implementation of the SVD deconvolution algorithm. Experiments were conducted to determine the effect of training set size, optimal patch size, and the effect of using different machine-learning models for regression. Results: Model performance increased with training set size, but after 5,000 samples (voxels) this effect was minimal. Models inferring perfusion maps from a 5 by 5 voxel patch outperformed models able to use the information in a single voxel, but larger patches led to worse performance. Random Forest models produced had the lowest root mean squared error, with neural networks performing second best: however, a phantom study revealed that the random forest was highly susceptible to noise levels, while the neural network was more robust. Conclusion: The machine learning-based approach produces estimates of the perfusion parameters invariant to the noise and artifacts that commonly occur as part of MR acquisition. As a result, better robustness to noise is obtained, when evaluated against the FDA approved software on acute stroke patients and simulated phantom data.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Perfusion Dynamic Susceptibility Contrast and Dynamic Contrast-Enhanced MR Imaging
    Ibrahim, Mohannad
    Ul Ghazi, Talha
    Bapuraj, Jayapalli Rajiv
    Srinivasan, Ashok
    [J]. MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2021, 29 (04) : 515 - 526
  • [2] Dynamic susceptibility MR perfusion imaging of the brain: not a question of contrast agent molarity
    Panara, Valentina
    Chiacchiaretta, Piero
    Rapino, Matteo
    Maruotti, Valerio
    Parenti, Matteo
    Piccirilli, Eleonora
    Pizzi, Andrea Delli
    Caulo, Massimo
    [J]. NEURORADIOLOGY, 2022, 64 (04) : 685 - 692
  • [3] Dynamic susceptibility MR perfusion imaging of the brain: not a question of contrast agent molarity
    Valentina Panara
    Piero Chiacchiaretta
    Matteo Rapino
    Valerio Maruotti
    Matteo Parenti
    Eleonora Piccirilli
    Andrea Delli Pizzi
    Massimo Caulo
    [J]. Neuroradiology, 2022, 64 : 685 - 692
  • [4] ASFNR Recommendations for Clinical Performance of MR Dynamic Susceptibility Contrast Perfusion Imaging of the Brain
    Welker, K.
    Boxerman, J.
    Kalnin, A.
    Kaufmann, T.
    Shiroishi, M.
    Wintermark, M.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2015, 36 (06) : E41 - E51
  • [5] Pitfalls and Artifacts in Dynamic Susceptibility Contrast MR Perfusion of Brain
    Mangla, R.
    Ekholm, S.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (05)
  • [6] Parametric mapping of scaled fitting error in dynamic susceptibility contrast enhanced MR perfusion imaging
    Li, KL
    Zhu, XP
    Jackson, A
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (869): : 470 - 481
  • [7] Crossed Cerebellar Diaschisis in Acute Stroke Detected by Dynamic Susceptibility Contrast MR Perfusion Imaging
    Lin, D. D. M.
    Kleinman, J. T.
    Wityk, R. J.
    Gottesman, R. F.
    Hillis, A. E.
    Lee, A. W.
    Barker, P. B.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2009, 30 (04) : 710 - 715
  • [8] Clinical applications of dynamic susceptibility contrast perfusion-weighted MR imaging in brain tumours
    Romano, A.
    Espagnet, M. C. Rossi
    Calabria, L. F.
    Coppola, V.
    Talamanca, L. Figa
    Cipriani, V.
    Minniti, G.
    Pierallini, A.
    Fantozzi, L. M.
    Bozzao, A.
    [J]. RADIOLOGIA MEDICA, 2012, 117 (03): : 445 - 460
  • [9] Dynamic susceptibility-weighted contrast-enhanced perfusion MR imaging in pediatric patients
    Cha, S
    [J]. NEUROIMAGING CLINICS OF NORTH AMERICA, 2006, 16 (01) : 137 - +
  • [10] Cerebral perfusion MR imaging using FAIR-HASTE in chronic carotid occlusive disease: Comparison with dynamic susceptibility contrast-perfusion MR imaging
    Ida, Kentaro
    Akaki, Shiro
    Sei, Tetsuro
    Tsunoda, Masatoshi
    Kanazawa, Susumu
    [J]. ACTA MEDICA OKAYAMA, 2006, 60 (04) : 215 - 221